Installing the 831-t5 Mesh AP

831-t5 Mesh AP QSG

2

6SDG831T5-13A

Installing the 831-t5 Mesh AP

Package Contents

■ Adtran’s 831-t5 Wi-Fi 5 Mesh AP
■ 12V DC power adapter
■ Ethernet cable

Prior to Installation

Before installing the equipment, inspect the device. If damage has occurred during shipping, file a claim with the carrier, and then contact Adtran 

Customer Support. For more information, refer to the product warranty available online at 

http://adtran.com/warranty-terms

.

Required Tools

No special tools are required for installing the 831-t5.

Mounting Options

There are two options to install the 831-t5: desktop and wall mount. Be sure to route and secure the cables in a manner that will prevent 

damage. These options are described below.

Desktop Installation

The 831-t5 can be placed on a desk or table.

Table 1

 shows the recommended minimum distance (in feet and meters) between the device and 

household appliances to reduce interference.

NOTE

g

Refer to the national, state and local electrical codes for the requirements for power, grounding, wiring, and installation methods.

CAUTION!

f

The product is intended for indoor use only. Ethernet and attached equipment are intended for use within the same building with 

equipotential bonding, and not intended to be placed in separate buildings or structures. Failure to deploy as described could result in 

permanent damage from lightning or other electrical events and voids the warranty.  Furthermore, all connections from outside of the 

building must be disconnected prior to use.

Table 1: Recommended Minimum Distance Between the SDG and Household Appliances

Household Appliance

Recommended Minimum Distance (in feet and meters)

Microwave ovens

30 feet / 9 meters

Baby monitor – analog

20 feet / 6 meters

Baby monitor – digital

40 feet / 12 meters

Cordless phone – analog

20 feet / 6 meters

Cordless phone – digital 

30 feet / 9 meters

Bluetooth devices

20 feet / 6 meters

ZigBee

20 feet / 6 meters

WARNING!

f

Ensure that the 831-t5 does not come in contact with water or other liquids.

CAUTION!

f

Ensure that the 831-t5 is not located in direct sunlight or next to any thermal obstructions.

Содержание 831-t5

Страница 1: ...page 5 Figure 1 831 t5 Mesh AP WARNING f Read all warnings cautions notes and installation instructions before installing or servicing this equipment 12VDC Power Input Reset Button 1G LAN USB 3 0 Host...

Страница 2: ...he national state and local electrical codes for the requirements for power grounding wiring and installation methods CAUTION f The product is intended for indoor use only Ethernet and attached equipm...

Страница 3: ...re is designed to simplify the pairing process between the devices Perform the following steps to activate WPS 1 Press the WPS button on the back of the 831 t5 for less than 5 seconds for 5GHz or more...

Страница 4: ...l output is 12V DC 5 with a minimum current rating of 3 0 Amps For US and Canadian applications a UL Listed limited power source LPS is supplied and required for use For deployment outside of North Am...

Страница 5: ...radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with minimum distance of 25 cm between the radiator and your body This device and i...

Страница 6: ...B NMB 3 B Canadian Department of Communications Radio Interference Regulations This digital apparatus Wi Fi 5 Mesh Access Point Model 831 t5 does not exceed the Class B limits for radio noise emissio...

Страница 7: ...n maximal d antenne permis pour les dispositifs utilisant la bande de 5725 5850MHz doit tre conforme la limite de la p i r e sp cifi e pour l exploitation point point et l exploitation non point point...

Отзывы: