4
617600132F1-13A
3. Before connecting to the service provider interface, clean the optical Interfaces of the SC/APC connectors.
4. Insert the fiber cable into the
WAN
port on the bottom of the gateway.
Connecting the Power Supply
1. Connect the end of the power adapter to the
Power
port on the rear panel of the gateway
2. Plug other end of the power adapter into the wall outlet.
3. Confirm that the power is connected properly. The
Power
LED should be lit on the front of the gateway.
Resetting the Gateway
A reset button is available if the 814-v6 needs to be rebooted. To reboot the 814-v6, press the
Reset
button on the rear panel of the gateway for
5
seconds
or less
. To reset the device to custom defaults, press the
Reset
button for
5 seconds
or more.
CAUTION!
f
The following safety actions are recommended:
■ Do not allow disconnected optical connectors to touch surrounding unrelated surfaces and do not touch optical surfaces for any reason other
than performing the cleaning process.
■ Do not use compressed air to clean optical connectors.
■ Clean the optical surfaces as follows:
♦ Use a fiberscope or videoscope to verify proper cleaning of connectors prior to connecting components together.
♦ Use pure alcohol (reagent grade, 99.5% pure) when cleaning the endface of the connectors. The alcohol can be applied with either
laboratory grade lint-free tissues or with pre-moistened optical grade wipes.
♦ Use microporous fabric spiral wrapped cleaning tips to clean bulkhead ferrules.
■ Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure.
f
ATTENTION!
L'utilisation des commandes ou reglages ou l'execution des procedures autres que celles specifiees dans les presentes exigences peuvent etre
la cause d'une exposition a un rayonnement dangereux.
NOTE
g
This product contains a Class 1 Laser module that complies with FDA 21 CFR 1040.10, 1040.11 and IEC 60825-1.
CAUTION!
f
To prevent breaking the fiber, do not exceed the fiber bend radius of 3.5 in (8.9 cm).
NOTE
g
Alternately, the device may be powered by a supported third-party UPS which may be connected via 7-pin molex connector, labeled
UPS
.