background image

C A U T I O N !

SUBJECT TO ELECTROSTATIC DAMAGE

OR DECREASE IN RELIABILITY

HANDLING PRECAUTIONS REQUIRED

Warranty:

ADTRAN will replace or repair this product within the warranty period if it does not 

meet its published specifications or fails while in service. Warranty information can be 

found online at 

www.adtran.com/warranty

.

Trademarks:

 Brand names and product names included in this document are trademarks, 

registered trademarks, or trade names of their respective holders.

Copyright © 2020 ADTRAN, Inc. All Rights Reserved.

ADTRAN CUSTOMER CARE:

From within the U.S.     1.888.423.8726

 

From outside the U.S. +1 256.963.8716

PRICING AND AVAILABILITY  1.800.827.0807

*61287787F1-13A*

S

PECIFICATIONS

Specifications for the Micro ONT are as follows:

Electrical

Voltage: 12.0 V typical

Minimum Voltage: 10.0 V

Maximum Voltage: 13.9 V

Maximum Power Consumption: 10 W

The Power LED is Off

Make sure the power cable connector 
is properly seated in the ONT power 
input.

Verify that the power adapter is 
plugged into a live AC outlet.

Check the power cable for shorts or 
breaks.

Disconnect the power input connector 
at the ONT; use a voltmeter to verify 
that the proper voltage level is present 
on the 12 V pin (power and power 
return) from the power adapter.

Check the UPS cable and ensure it is 
properly seated in the UPS port.

Disconnect the UPS cable and use a 
voltmeter to check for 12 VDC 
between pins 1 and 5.

Check the UPS cable for shorts or 
opens.

The LAN LED is green

During boot-up, the LED will flash 
green. This is normal. Once boot-up is 
complete, the LED will become solid 
green. When data is transmitted, the 
LED will flash green. If the LED 
remains solid green, contact the 
Central Office to verify that the ONT 
serial number, password, and vendor 
ID match those provisioned in the 
database.

If provisioning is correct, have the 
Central Office determine if there are 
alarms on the PON feeding the ONT. If 
no alarms exist, use an optical power 
meter to troubleshoot the fiber 
network.

Problem

Possible Solution

Physical

Width: 2.8 in (7.1 cm)

Depth: 4.0 in (10.2 cm)

Height: 1.2 in (3.0 cm)

Weight: 1 lbs (0.45 kg)

Environmental

Operational Temperature: 32°F to +104°F (0°C to +40°C)

Storage Temperature: –4°F to 122°F (–20°C to +50°C)

Relative Humidity: 90%, noncondensing

Optical

TX min power: +0.5 dBm

TX max power: +5.0 dBm

RSSI max sensitivity: –27 dBm

RX overload: –8 dBm

TX wavelength: 1310 nm typical

RX wavelength: 1490 nm typical

M

AINTENANCE

The Micro ONT does not require routine hardware maintenance 
for normal operation. We do not recommend that you attempts 
repairs in the field. Obtain repair services by returning the 
defective unit to ADTRAN. Refer to the warranty for further infor-
mation. Field support for software is provided through upgrade 
facilities.

S

AFETY

 

AND

 R

EGULATORY

 

Refer to the

 

Safety and Regulatory Notice for this product

(P/N 61287787F1-17) for detailed safety and regulatory infor-
mation.
Consultez l'avis sur la sécurité et la conformité à la réglementation 
pour ce produit (P/N 61287787F1-17) pour obtenir des renseigne-
ments détaillés sur la sécurité et la réglementation.

Ausführliche Sicherheits- und regulatorische Informationen sind in 
der Konformitätserklärung zur Sicherheit und Einhaltung von 
Normen zu diesem Produkt (6

1287787F1-17) aufgeführt.

Documentation for ADTRAN Network Solutions products is available for 

viewing and download directly from the ADTRAN Support Community 

website. 
Go to: 

https://supportforums.adtran.com/welcome

Registration is required.
ADTRAN offers training courses on our products, including customized 

training and courses taught at our facilities or at customer sites.
For inquiries, go to:

 http://adtran.com/training

The following online documents and resources provide additional information for this product:

Total Access 5000 GPON OLT User Interface Guide
Total Access 5000 Series Fiber to the Premises Deployment Guide

Содержание 411

Страница 1: ...al up connections AC Power The power feed is 12 VDC from the included AC to DC Adapter The adapter plugs into the PWR connector UPS The Micro ONT provides an optional connection for an uninterpre table power source UPS An UPS is a battery backup system designed to continue providing power when the primary power source is lost Power is supplied to the Micro ONT by a local power source with battery ...

Страница 2: ...ling the Micro ONT inspect it for damage If damage has occurred during shipping file a claim with the carrier and then contact ADTRAN For more information refer to the warranty Installation Guidelines The following are guidelines for this installation Read all warnings and cautions before installing or servicing the Micro ONT Do not locate the Micro ONT in direct sunlight or next to any thermal ob...

Страница 3: ...1187731G3 and GPON Indoor UPS Power Cable P N 1287402G1 for providing an UPS power source Incoming Fiber UPS Power Alarm Table The following table indicates which pin is associated with each alarm provided through a UPS connection LED STATUS The LEDs are located beneath the plastic housing and are only visible after power has been applied The following table provides the LED status during normal o...

Страница 4: ...ral Office determine if there are alarms on the PON feeding the ONT If no alarms exist use an optical power meter to troubleshoot the fiber network Problem Possible Solution Physical Width 2 8 in 7 1 cm Depth 4 0 in 10 2 cm Height 1 2 in 3 0 cm Weight 1 lbs 0 45 kg Environmental Operational Temperature 32 F to 104 F 0 C to 40 C Storage Temperature 4 F to 122 F 20 C to 50 C Relative Humidity 90 non...

Отзывы: