12
Issue 1, December 2003
61223404L2-5A
Abbreviations used in the
Performance History
screens
are defined in
Performance Data Definitions
screens, as
in
shows the Line related definitions, and
shows the Path related definitions.
Figure 15. Performance Data Definitions
Figure 16. Performance Data Definitions (Continued)
Circuit ID: 11/03/03 09:29:45
Performance Data Definitions
H4TUC, H4TUR, and H4R LOOP Related: HDSL4 Framing
ES-L Errored Seconds CRC>=1 or LOSW>=1
SES-L Severely Errored Seconds CRC>=50 or LOSW>=1
UAS-L Unavailable Seconds >10 cont. SES-Ls
DS1 and DSX-1 Line Related: Superframe and Extended Superframe
ES-L Errored Seconds (BPV+EXZ)>=1 or LOS>= 1
SES-L Severely Errored Seconds (BPV+EXZ)>=1544 or LOS>=1
LOSS-L Loss of Signal Seconds LOS>= 1
PDVS-L Pulse Density Violation Secs EXZ>=1; >7 zeros if B8ZS, >15 if AMI
B8ZS-L B8ZS Seconds B8ZS coded signal received
CV-L Code Violation Count (BPV+EXZ) count
NOTE: Reverse video indicates invalid data due to a terminal restart (or power
cycle), a data register reset, or a system date or time change.
N. Next
P. Previous Selection:
Circuit ID: 11/03/03 09:29:45
Performance Data Definitions
DS1 and DSX-1 Path Related: Superframe Extended Superframe
ES-P Errored Seconds FE>=1 or CRC>=1 or
SEF>=1 or AIS>=1 SEF>=1 or AIS>=1
SES-P Severely Errored Seconds FE>=8 or CRC>=320 or
SEF>=1 or AIS>=1 SEF>=1 or AIS>=1
UAS-P Unavailable Seconds >10 cont. SES-Ps >10 cont. SES-Ps
SAS-P SEF/AIS Seconds SEF>=1 or AIS>=1 SEF>=1 or AIS>=1
ES-PFE Far End Errored Seconds n/a PRM bits G1-G6,SE,
or SL=1, or RAI
CV-P Code Violation Count FE count CRC error count
NOTE: Under a UAS-P condition, ES-P and SES-P counts are inhibited.
Under a SES-L or SES-P condition, the respective CV-L or CV-P count is
inhibited.
P. Previous Selection:
Содержание 3192 H4TU-C