background image

JOB

A

ID

239 H4R

CLEI: T1R5YP3D_ _

239 H4R

1221445L1

LP1

NET

LP2

LP1

LP2

LL  RL
(Y)  (G)

/

CUST

61221445L1-22B

0205

CARD EDGE PIN ASSIGNMENTS

LOOPBACK AND CONTROL CODES

Refer to the Installation and Maintenance Practice of the H4TU-C or H4TU-R used in
the circuit for a list of loopback codes.

■  

For a complete Installation and Maintenance Practice (P/N 61221445L1-5) faxback: (877) 457-5007, faxback Document 755.  Please have your fax number ready.  

C A U T I O N 

C A U T I O N ! 

SUBJECT TO ELECTROSTATIC DAMAGE

OR DECREASE IN RELIABILITY.

HANDLING PRECAUTIONS REQUIRED.

STATUS LEDs

LP1/LP2 NET

Off 

No span power present

Solid Green

Synchronized with an SNR margin greater than the user defined SNR 
Margin Alarm Threshold

Fast Blinking (Blinking 3 times per second) Attempting to synchronize with the 
Green

H4TU-C

Slow Blinking (Blinking 1 time per second) Synchronized with an SNR margin 
Green

greater than the user defined SNR Margin Alarm Threshold and the 
pulse attenuation is greater than the user defined Loop Attenuation 
Alarm Threshold

Solid Yellow

Synchronized with an SNR margin greater than 0 dB but less than 
the user defined SNR Margin Alarm Threshold

Slow Blinking Synchronized with an SNR margin greater than 0 dB but less than the 
Yellow

user defined SNR Margin Alarm  Threshold and the pulse attenuation 
is greater than the user defined Loop Attenuation Alarm Threshold

Solid Red

Synchronized with an SNR margin of 0 dB

Slow Blinking (Blinking 1 time per second) Synchronized with an SNR margin of 0 dB
Red

and the pulse attenuation is greater than the user defined Loop 
Attenuation Alarm Threshold

LP1/LP2 CUST

Off 

No span power present

Solid Green 

Synchronized with an SNR margin greater than the user defined SNR 
Margin Alarm Threshold

Fast Blinking (Blinking 3 times per second) Attempting to synchronize with the
Green

H4TU-R

Slow Blinking (Blinking 1 time per second) Synchronized with an SNR margin 
Green

greater than the user defined SNR Margin Alarm Threshold and the 
pulse attenuation is greater than the user defined Loop Attenuation 
Alarm Threshold

Solid Yellow 

Synchronized with an SNR margin greater than 0 dB but less than the 
user defined SNR Margin Alarm Threshold

Slow Blinking Synchronized with an SNR margin greater than 0 dB but less than the 
Yellow

user defined SNR Margin Alarm  Threshold and the pulse attenuation 
is greater than the user defined Loop Attenuation Alarm Threshold

Solid Red 

Synchronized with an SNR margin of 0 dB

Slow Blinking (Blinking 1 time per second) Synchronized with an SNR margin of 0 dB
Red

and the pulse attenuation is greater than the user defined Loop 
Attenuation Alarm Threshold

LL/RL

Green 

Indicates a loopback at the H4R toward the H4TU-R is active

Yellow 

Indicates a loopback at the H4R toward the H4TU-C is active

Blinking 

Armed but not in loopback.

Yellow

Pin No.

Designation

Description

Pin No.

Designation

Description

1

GND

Ground

7

NC

No Connection

2

NC

No Connection

8

T

Network Loop 2 Tip

3

T1

Customer Loop 1 Tip

9

R

Network Loop 2 Ring

4

R1

Customer Loop 1 Ring

10

GND

Ground

5

T1

Network Loop 1 Tip

11

T

Customer Loop 2 Tip

6

R1

Network Loop 1 Ring

12

R

Customer Loop 2 Ring

#61221445L1-22B#

239 H4R

Отзывы: