Support - Phone: 888-423-8726, Email: [email protected]

Quick Start Guide, 61700595G10-13B, March 2015

3

3.

Provide power to the unit as appropriate. Refer to the 

NetVanta 1235P Hardware Installation 

Guide

 at 

https://supportforums.adtran.com

 for more details.

4.

Once the unit is powered up, open a VT100 terminal session using the following settings: 
9600 baud, 8 data bits, no parity bits, 1 stop bit, and no flow control. Press 

<Enter>

 to 

activate the AOS CLI.

5.

Enter 

enable

 at the 

>

 prompt and enter the Enable mode password when prompted. The 

default password is 

password

.

You can also access the CLI from a Telnet or SSH client. In order to do this, you must know the IP 
address of the AOS device. If you do not know the unit’s IP address, you must use the 

CONSOLE

 

port to access the CLI. To access the CLI using a Telnet or SSH client, follow these steps:
1.

Connect the unit to your PC, using an Ethernet cable connected to the GIG 0/1 Gigabit 
Ethernet port on the rear of the unit. 

2.

Open a Telnet or SSH client on your computer and enter 

10.10.10.1

. If you have changed 

your unit's IP address, you will need to enter that address.

3.

For SSH, log into the unit using the default login (

admin

) and password (

password

). For 

Telnet, only the default password (

password

) is required.

4.

Enter 

login

 to require a password for Telnet or SSH access.

5.

Enter 

enable 

at the 

>

 prompt and enter the enable password when prompted. The default 

password is 

password

.

C

OMMON

 CLI C

OMMANDS

The following are common CLI commands and tips for getting started with the CLI.

Entering a question mark (?) shows contextual help and options. For example, entering 

?

 at 

the prompt will show all commands available from that prompt.

To view interface statistics, enter 

show interfaces 

<interface type> <interface number>

.

To view the current configuration, enter 

show running-config

.

To view all the IP addresses currently configured, enter 

show ip interfaces brief

.

To view the AOS version, serial number, and other information, enter 

show version

.

To save the current configuration, enter 

write

.

A

CTIV

R

EACH

 E

THERNET

The NetVanta 1235P has 24 10/100/1000Base-T Ethernet ports that support both standard and 
ActivReach Ethernet. When used in conjunction with the NetVanta ActivReach Media Converter 
(P/N 1702595G12) or the NetVanta ActivReach Wall Plate Media Converter (1702595F17), 
ActivReach Ethernet is converted to standard 10/100Base-T over 1-, 2-, and 4-pair infrastructure 
wiring over a variety of cables at distances beyond 100 meters. The NetVanta ActivReach Wall 
Plate Media Converter also supports 1-pair ActivReach with optional voice passthrough 
connections via separate front and back RJ-11 jacks.
For applications requiring connection into a single RJ-21, a hydra interconnect cable 
(P/N 1702595G14) can be used. This cable is suitable for 10 Mbps applications only. Refer to the 

NetVanta 1235P Hardware Installation Guide

 at 

https://supportforums.adtran.com

 or 

http://www.adtran.com/activreach-help

 for more information."

Many PCs do not come with a standard serial port. A universal serial 

bus (USB) to serial adapter can be used instead. The drivers for the USB 

to serial adapter must be installed according to the manufacturer’s 

instructions. If the USB to serial adapter is not properly installed on your 

PC, you will not be able to communicate with the AOS unit and you 

should seek support from the USB to serial adapter manufacturer.

P

OWER

 

OVER

 E

THERNET

The NetVanta 1235P is a Power over Ethernet (PoE) switch. PoE switches provide the ability to 
detect attached powered devices (PDs) and deliver power to the PD via existing Ethernet 
cabling. The NetVanta 1235P is fully compliant with the IEEE 802.3af PoE standard. By default, 
the PoE switches discover and provide power to IEEE-compliant PDs. 
ActivReach Ethernet supports Power over Ethernet (PoE) over a single pair. When used in 
conjunction with the NetVanta ActivReach Media Converter (P/N 1702595G12), power can be 
either terminated at the Media Converter or supplied to a downstream device. 
To disable PoE, use the 

power inline never 

command in the CLI. To disable PoE from the GUI, 

select the 

Ports

 page. Then select a single port from the list (e.g., 

giga-swx 0/1

). This will bring 

up the port detail page for 

giga-swx 0/1

. On this page, there is a check box to disable PoE.

C

ONFIGURE

 

THE

 U

NIT

S

 IP A

DDRESS

The following steps create an IP address and subnet mask for the virtual local area network 
(VLAN) interface 

vlan 1

. If you are not sure what IP address to assign, please contact your 

network administrator.
1.

At the

 #

 prompt, enter 

config terminal

.

2.

At the 

(config)#

 prompt, enter 

interface vlan 1

 to access the configuration parameters for 

the VLAN interface.

3.

Enter 

ip address 10.26.12.12 255.255.255.0 

to assign an IP address to the VLAN interface 

using a 24-bit subnet mask.

4.

Enter 

no shutdown

 to activate the VLAN interface to pass data.

5.

Enter 

exit

 to return to the Global Configuration mode.

6.

Enter 

ip route 0.0.0.0 0.0.0.0 192.168.1.254

 to add a default route to the route table. 

0.0.0.0

 is the default route and the default subnet mask, and 

192.168.1.254

 is the next-hop 

IP address to which the AOS unit should send all of its traffic. You will need to enter the 
proper route, subnet mask, and gateway for your network. This information is typically 
provided by a service provider or local network administrator.

7.

Enter 

do write memory

 to save the current configuration.

E

NABLE

 T

ELNET

 U

SER

 L

OGIN

 A

CCESS

The following steps enable user login parameters for Telnet access by changing the password 
from the default (

password

) and enabling security login on Telnet lines.

1.

Verify that the prompt of your unit displays 

(config)#

.

2.

Enter 

line telnet 0 4

 to change the configuration parameters for the Telnet sessions.

3.

Enter 

login

 to prompt users with a login prompt for Telnet access.

4.

Enter 

password adtran

 to change the login password for the Telnet sessions.

5.

Enter 

exit

 to return to the Global Configuration mode.

6.

Verify that the prompt of your unit displays 

(config)#

.

7.

Enter 

do write memory

 to save the current configuration.

The configuration parameters used in the examples outlined in this 

document are for instructional purposes only. Please replace all 

underlined entries (

example

) with your specific parameters to configure 

your application.