background image

D

ESCRIPTION

The Small Form-Factor Pluggable 10 Gigabit 
Ethernet XFP, 1550 nm, Temperature Hardened  
(XFP) optical transceiver is a fully duplex serial 
electric, serial optic device with both transmit and 
receive functions contained in a single module that 
provides a high speed serial link at 10 Gb/s. Installed 
into an appropriate host module, the XFP provides a 
10 Gigabit interface to the supporting system.
The transmit side of the XFP converts serial NRZ 
electrical date at the10 Gb/s line rate to a standard 
compliant optical signal. The receive side of the XFP 
converts the incoming DC balanced serial NRZ 
optical data at the 10 Gb/s line rate into serial 
electrical data.

NOTE

To ensure compatibility, refer to the documentation
provided with the host module.

The following features are supported on the XFP:

1550 nm optical signals for up to 40 km reach

Case temperature hardened range from –40°C to 

85°C

Low power consumption (<3.5 W max)

Excellent EMI performance

Due to compliance certification requirements, only
XFPs supplied by ADTRAN are to be used with the
host module. ADTRAN cannot certify system integrity
with other XFPs.

Small Form-Factor Pluggable

 10 Gigabit Ethernet XFP, 1550 nm,

Temperature Hardened 

Operational Specifications

Optical Specifications:

Transmit Wavelength: 1550 nm

Receive Wavelength: 1530 to 1565 nm

Data rate: 9.95 Gb/s to 11.35 Gb/s

Optical transmit level: –4.7 to +4.0 dBm

Optical receive level: –15.0 to –11.3 dBm

Optical distance: 40 km maximum

Optical connectors: LC

Extended Environmental Support:

Operational temperature range: –40°C to +85°C

Storage temperature range: –40°C to +85°C

Relative humidity to 85%, noncondensing

I

NSTALLATION

Inspect the XFP. If damaged, file a claim with the 
carrier and then contact ADTRAN Customer Service.
To install the XFP into an appropriate module, 
complete the following steps:

1. Insert the XFP into the XFP cage on the circuit 

board of the host module with the latch handle 
facing outward. Slide the XFP all the way into the 
receptacle.

NOTE

The latch on the XFP is for removal only. When
removing the XFP, rotate the latch away from the XFP
cage until a physical click occurs. The XFP should
slide easily out of the cage.

2. Using thumb and forefinger, exert adequate 

pressure to ensure the XFP is completely seated 
in the XFP cage.

3. Do not remove the connector plug until the 

optical fiber connection is made.

It is recommended that the connector plug remain on
whenever the transceiver optical fiber connector is
not inserted.

4. Continue the installation and turn-up of the host 

module using the instructions in the Job Aid 
provided with that module, or using the 
Installation and Maintenance Practice (I&M), 
available online at 

www.adtran.com

.

CLEI: BVL3ADMD_ _
Product P/N: 1442940G1

Issue Date: 0810

Document P/N: 61442940G1-22A