job
Aid
D
ESCRIPTION
The
Small
Form
‐
Factor
Pluggable
(SFP)
is
a
copper
SFP
that
plugs
into
an
ADTRAN
GigE
Copper
interface
designed
to
accept
SFPs.
The
SFP
provides
a
single
electrical
interface
to
a
physical
interface.
Installed
into
an
appropriate
module,
this
SFP
provides
a
10/100/
1000
Mbps
full
duplex
data
‐
link.
The
following
features
are
supported
on
the
SFP:
♦
Up
to
1.25
Gbps
bidirectional
data
links
♦
Hot
‐
pluggable
footprint
♦
100
meter
maximum
distance
over
shielded
twisted
‐
pair
Cat
5
cable
♦
Supports
10/100/1000
Mbps
using
the
appropriate
module/
platform
Operational Specifications
♦
Extended
Environmental
Support:
◊
Operational
temperature
range:
–40°C
to
+85°C
◊
Storage
temperature
range:
–40°C
to
+85°C
◊
Relative
humidity
to
95%,
noncondensing
◊
Operating
Altitude
Range:
–197
(–60
meters)
to
13000
feet
(3962
meters)
NOTE
The
operating
ambient
temperature
is
derated
by
1°C
/1000
feet
(3.3°C
/km).
CAUTION
!
Due
to
compliance
certification
requirements,
only
SFPs
approved
by
ADTRAN
are
to
be
used
with
the
host
module.
ADTRAN
cannot
certify
system
integrity
with
other
SFPs.
I
NSTALLATION
To
install
the
SFP
into
an
appropriate
module,
complete
the
following
steps:
Inspect
the
SFP.
If
damaged,
file
a
claim
with
the
carrier
and
then
contact
ADTRAN
Customer
Support.
CAUTION
!
If
present,
do
not
remove
the
protective
end
cap
from
the
SFP
until
the
Cat
5
cable
is
ready
to
be
connected.
1. Insert
the
SFP
into
the
SFP
cage
on
the
module.
Ensure
the
latch
on
the
SFP
is
facing
upward
for
correct
installation.
2. Slide
the
SFP
all
the
way
into
the
SFP
cage
until
there
is
an
audible
“click”.
NOTE
♦
The
latch
on
the
SFP
is
used
to
remove
the
SFP
from
the
cage
on
the
circuit
card.
♦
The
SFP
meets
or
exceeds
all
the
applicable
requirements
of
NEBS,
Telcordia
GR
‐
63
‐
CORE,
and
GR
‐
1089
‐
CORE.
COMPLIANCE
WARNING
!
The
SFP
port
is
classified
as
Type
2
or
Type
4,
as
defined
in
Appendix
B
of
GR
‐
1089
‐
CORE
Issue
5,
and
is
suitable
for
connection
to
intra
‐
building
or
unexposed
wiring
or
cabling
only.
Do
not
metallically
connect
this
port
to
interfaces
which
connect
to
Outside
Plant
(OSP)
or
to
the
OSP
wiring.
The
SFP
port
is
designed
for
use
as
an
intrabuilding
interface
only
(Type
2
or
Type
4),
and
requires
isolation
from
exposed
OSP
cabling.
The
addition
of
Primary
Protectors
is
not
sufficient
protection
in
order
to
connect
this
interface
metallically
to
OSP
wiring.
The
SFP
port
is
suitable
for
connection
only
to
shielded
intra
‐
building
cabling
grounded
at
both
ends.
CAUTION
!
Electrostatic
Discharge
(ESD)
can
damage
electronic
modules.
When
handling
modules,
wear
an
antistatic
discharge
strap
to
prevent
damage
to
electronic
components.
Place
modules
in
antistatic
packing
material
when
transporting
or
storing.
When
working
on
modules,
always
place
them
on
an
approved
antistatic
mat
that
is
electrically
grounded.
NOTE
The
SFP
has
been
evaluated
to
international
safety
standards
EN
60950
‐
1,
AS/NZS
60950.1,
and
IEC
60950
‐
1.
The
SFP
meets
the
requirements
for
CE
marking
under
the
EMC
Directive
and
Low
Voltage
Directive.
Standards
used
to
demonstrate
Compliance
are
EN
300
386,
EN
50222,
EN
55024
as
applicable
and
EN
60950.
CAUTION
!
The
SFP
is
intended
for
deployment
in
Central
office
type
facilities,
EEEs,
EECs,
and
locations
where
NEC
applies
(for
example,
Customer
Premises).
The
SFP
must
be
installed
by
trained
service
personnel
in
ADTRAN
products
that
are
located
in
Restricted
Access
Locations.
CLEI: SOOTAK9J_ _
Product P/N: 1442300G1
Issue Date: April 2010
Document P/N: 61442300G1-22B
Small Form-Factor Pluggable
1.25 GigE Copper SFP