Safety and Regulatory
61287802F1-34B
15
Revision B
3 Safety and Regulatory
CAUTION!
f
Electrostatic Discharge (ESD) can damage electronic modules. When handling modules, wear
an antistatic discharge wrist strap to prevent damage to electronic components. Place
modules in antistatic packing material when transporting or storing. When working on
modules, always place them on an approved antistatic mat that is electrically grounded.
Table 3
shows the configuration codes for the GPON 452/454. The GPON 452/454 is NRTL
listed to the applicable UL standards. The GPON 452/454 is intended for deployment in the
Outside Plant (OSP) at locations where the NEC applies (for example, Customer Premises)
and is intended to be installed by trained service personnel.
This device complies with Part 15 of the FCC rules. Operation is subject to the following two
conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause
undesired operation.
Changes or modifications not expressly approved by ADTRAN will void the warranty.
WARNING!
f
The 10/100/1000Base-T port and POTS port(s) are classified as Type 4 as defined in
Appendix B of GR-1089-CORE, Issue 5, and are suitable for connection to intra-building or
unexposed wiring or cabling only. Do not metallically connect these ports to interfaces which
connect to the Outside Plant (OSP) or to the OSP wiring. The 10/100/1000Base-T port(s), and
POTS port(s) are designed for use as an intra-building interface only (Type 4 ports as
described in GR-1089-CORE, Issue 5) and require isolation from exposed OSP cabling. The
addition of Primary Protectors is not sufficient protection in order to connect this interface
metallically to OSP wiring.
Table 4. Configuration Codes
Configuration Codes
Input
Output
Power Code (PC)
F
C
Telecommunication Code (TC)
–
X
Installation Code (IC)
A
–
C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY
HANDLING PRECAUTIONS REQUIRED