Chapter 11. Testing and Troubleshooting
61202011L1-1
DSU III AR User Manual
11-5
TROUBLESHOOTING
This section is intended to provide a quick and easy means of
diagnosing suspected problems associated with local or remotely
attached ADTRAN DSU/CSUs. Two separate troubleshooting
sections are provided; one focuses on new installs, the other on
existing circuits.
Messages from the DSU/CSU
The DSU III AR displays messages on the LCD display and LEDs
concerning the status of the unit and the local loop. If the Alarm
LED is
O
N
, at least one of the messages shown in Table 11-1 will be
displayed on the LCD.
The
S
TATUS
menu must be selected in order for the unit to display status
messages. Press the
Quick
key to return to the main menu, where
S
TATUS
can be selected.
Table 11-1. Messages from the DSU/CSU
Message
Meaning
Probable Cause
Action
LOOP IS
NORMAL
Good local loop sig-
nal being received
from the telco.
Indicates good local
loop.
No action required; unit
properly connected to telco
circuit.
OPEN LOOP
Unit not receiving a
signal from the telco.
Bad telco cable from
the DSU to telco jack
or bad circuit to telco.
Replace telco cable from
DSU to wall jack. If a prob-
lem persists, contact telco
provider.
NO RX
SIGNAL
Unit detects sealing
current but no data
signal from telco.
Bad conductor in telco
cable from DSU to tel-
co jack or bad circuit to
telco.
Replace telco cable from
DSU to wall jack. If a prob-
lem persists, contact telco
provider.
OOS/OOF
FROM NET
Unit detects an Out of
Service or Out of
Frame condition from
the telco.
Telco is having prob-
lems with DDS circuit
or remote unit is turned
off or disconnected.
Check remote unit. Contact
telco service provider. If a
problem persists, contact tel-
co provider.
Содержание 1202011L1
Страница 1: ...DSU III AR Data Service Unit User Manual Part Number 1202011L1 61202011L1 1C May 2001...
Страница 18: ...Table of Contents xviii DSU III AR User Manual 61202011L1 1...
Страница 24: ...List of Tables xxiv DSU III AR User Manual 61202011L1 1...
Страница 72: ...Chapter 6 Configuring DTE Options 6 18 DSU III AR User Manual 61202011L1 1...
Страница 82: ...Chapter 9 Manual Command 9 4 DSU III AR User Manual 61202011L1 1...
Страница 110: ...Chapter 11 Testing and Troubleshooting 11 26 DSU III AR User Manual 61202011L1 1...
Страница 130: ...Appendix B AT Commands B 12 DSU III AR User Manual 61202011L1 1...
Страница 134: ...Appendix C Default Configuration Profiles C 4 DSU III AR User Manual 61202011L1 1...
Страница 136: ...Appendix D EIA 232 Connector D 2 DSU III AR User Manual 61202011L1 1...
Страница 140: ...Appendix E DSU to DSU Tail Circuit E 4 DSU III AR User Manual 61202011L1 1...
Страница 144: ...Appendix F Specifications Summary F 4 DSU III AR User Manual 61202011L1 1...
Страница 158: ...Appendix H Glossary H 10 DSU IV ESP User Manual 61204011L1 1...