Global Configuration Mode Command Set
61200630L1-35C
37
line console <line-number>
Purpose
Use the line console
<line-number> command to enter the line configuration command set for
the specified console session. Refer to
“Line (Console) Interface Config Command Set”
page 66 for information on the subcommands found in this command set.
Syntax Description
displays the syntax descriptions for the line console <line-number> command.
Default Values
By default, the Total Access 238 line console parameters are configured as follows:
Data Rate: 9600 baud
Data bits: 8
Stop bits: 1
Parity Bits: 0
No flow control
Command Modes
The Global Configuration Mode is required for this command.
Usage Examples
Begin the configuration for the
CRAFT
port located on the front panel of the unit.
TA238(config)#line console 0
The following response is displayed:
TA238(config-con0)#
Table 15. Syntax Description for line console <line-number>
Syntax
Description
console
Specifies the DB-9 (female) CONSOLE port located on the rear panel of the unit.
line-number
Specifies the starting console session to configure for remote access (valid range
for console: 0).