![ADTRAN 1200315L1 Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/adtran/1200315l1/1200315l1_user-manual_2854363025.webp)
Chapter 3. Operation
61200315L1-1
Quad BRI/U Module User Manual
3-3
T
YPE
Write security: 3; Read security: 5
Displays the type of module actually installed in the slot or the type of
module you plan to install in the slot. If a Quad BRI/U Module is installed,
the Type field automatically defaults to U-BRI (the Quad BRI/U Module).
You can use this field to preconfigure a system before actually installing
modules by simply specifying the module that you want to install in each
slot.
M
ENU
Displays additional status and configuration menus for the selected module.
(To access the submenus for this item, use the arrow keys to scroll to the
Menu column for the module you want to edit, and press
Enter
.) For detailed
information on each submenu item, see the section Quad BRI/U Module
Menus on page 3-4.
A
LARM
Read security: 5
Displays an alarm condition on the Quad BRI/U Module. Press
Enter
in this
field to activate the menu.
T
EST
Read security: 5
Displays test name if the Quad BRI/U Module is executing a test. Press
Enter
in this field to activate the menu. This menu can activate a local loop-
back toward the U-interface (
LOC "U" LB
) for each port (
P
RT
). The loop-
back options include
B1 L
OOPBACK
,
B2 L
OOPBACK
, or
A
LL
.
S
TATE
Displays module status as either
O
NLINE
of
O
FFLINE
. Even though a module
is physically installed, it must be marked as online for it to be considered an
available resource. This parameter allows an installed module to be marked
as offline, which may be useful in system troubleshooting. If you choose to
mark a module as offline, the module will not be in alarm condition, but will
display
O
FFLINE
.
S
TATUS
This read-only field provides status information on the Quad BRI/U Module.
The following messages may display:
O
NLINE
The module is enabled, and is responding to the system controller’s status
polls. This is the normal response of the system.
T
YPE
automatically displays the name of an installed module. If you
want to preconfigure the slot for a different type of module, you must
set this field to
E
MPTY
before selecting another module type.
Once a module is installed, the state must be set to Online in order for
the ATLAS to use the module for any data bandwidth.
Содержание 1200315L1
Страница 1: ...Quad BRI U Module User Manual Part Number 1200315L1 61200315L1 1B April 2000 ...
Страница 8: ...viii ...
Страница 12: ...List of Figures xii Quad BRI U Module User Manual 61200315L1 1 ...
Страница 13: ...61200315L1 1 Quad BRI U Module User Manual xiii List of Tables Table 2 1 Network Pinout Connection 2 3 ...
Страница 14: ...List of Tables xiv Quad BRI U Module User Manual 61200315L1 1 ...
Страница 18: ...Chapter 1 Introduction 1 4 Quad BRI U Module User Manual 61200315L1 1 ...
Страница 22: ...Chapter 2 Installation 2 4 Quad BRI U Module User Manual 61200315L1 1 ...
Страница 34: ...Appendix A Dial Plan Configuration A 6 Quad BRI U Module User Manual 61200315L1 1 ...
Страница 36: ...Index Index 2 Quad BRI U Module User Manual 61200315L1 1 ...
Страница 38: ......