ASYNC-232 Menu Description
Chapter 3. Operation
61200182L1-1
Async-232 Module User Manual
3-3
Alarm
Read security: 5
Displays whether there is an alarm condition on the Async-232 Module. Press
Enter
in this field to activate the Alarm menu.
Test
Read security: 5
Displays whether the Async-232 Module is executing a test. Press Enter in this
field to activate the Test menu.
State
Read security: 5
Displays whether the module is online or offline. Even though a module is phys-
ically installed, its status must be marked Online for it to be considered an avail-
able resource. Marking an installed module Offline may be useful in system
troubleshooting. If you choose Offline, the module will not be in alarm condition,
but will display Offline.
Only if State reads Online can the ATLAS use an installed module for any data
bandwidth.
Status
Read security: 5
Displays status information on the Async-232 Module. Table 3-2 describes status
messages, and their meanings, that may appear.
Rev (Hardware Revision)
Read security: 5
Read-only field that displays the hardware revision of the Async-232 Module.
Table 3-2. Async-232 Module Status Messages
Message
Meaning
Comments
Online
The module is enabled and is respond-
ing to the system controller’s status
polls.
This is the normal response of
the system.
No Response
The module is enabled but is not
responding to the system controller’s
status polls.
This response indicates either a
problem in the system or the
module is not installed.
Empty
The system controller has not detected
the presence of a module in the option
slot, nor has a module been manually
enabled for this option slot.
Offline
The module is installed but has been
taken Offline by a user.
The module is still responding
to controller polls.
Offline /
No Response
The module is installed but has been
taken Offline by a user. The module is
not responding to polls.
This response indicates either a
problem in the system or the
module is not installed.
Содержание 1200182L1
Страница 1: ...Async 232 Module USER MANUAL Part Number 1200182L1 61200182L1 1A August 1998...
Страница 4: ...iv Async 232 Module User Manual 61200182L1 1...
Страница 6: ...Table of Contents vi Async 232 Module User Manual 61200182L1 1...
Страница 8: ...List of Figures viii Async 232 Module User Manual 61200182L1 1...
Страница 10: ...List of Tables x Async 232 Module User Manual 61200182L1 1...
Страница 16: ...Chapter 2 Installation Warranty and Customer Service 2 4 Async 232 Module User Manual 61200182L1 1...
Страница 32: ...Chapter 3 Operation Async 232 Module Submenus Test 3 16 Async 232 Module User Manual 61200182L1 1...
Страница 44: ...Appendix C Failure Messages FLASH Invalid C 2 Async 232 Module User Manual 61200182L1 1...
Страница 48: ...Index Index 4 Async 232 Module User Manual 61200182L1 1...
Страница 50: ......