![ADTEK CM1-CT Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/adtek/cm1-ct/cm1-ct_manual_2854176003.webp)
2
■
Operating Key
Operating Key : Up key (1~6, 5 and 6 are same a key) Enter/Function key
In parameter setting page, if didn’t press any key over 2 minutes, or press over 1 second,
then return to measuring page
Function
Enter/Function key
(1~6) Up key
(1) In function index page, press 1 second to back to previous page
(2) In function setting page, press 1 second to back to function index page
(3) In function setting page, press to next function page
(4) In parameter setting, press 1 second will abort setting and go back function page
(5) In parameter setting, press to enter value or con
fi
rm selection
(1)In function index page, press to function select
(2)In parameter setting, press to parameter select or numeric input
(press and hold can accelerate the numeric increase)
■
Operating Flow Chart
Power ON
88888
cm1ct
ver1.5
1688.8
enter
Pcode
Pass code
MEASURING PAGE
Press 1 second
Press one second
NO
YES
Enter pass code into
Programming Level
Default :1000
0-0-1
19999
Counting value
(Normal)
0-1
ry1.sp
Relay1 set-point
1~999999
(In mode setting range
can be -199999~999999)
10000
totl.l
totl.h
0-2
ry2.sp
Relay2 set-point
1~999999
(-199999~999999 same as Relay 1)
10000
0-3
cm1.ct
Model name and
fi
rmware version
dislay
ver1.5
User Level
User Level
Programming Level
group
relay
RELAY GROUP
group
ao
AO GROUP
group
input
INPUT GROUP
group
init
INIT GROUP
A-1
B-1
C-1
D-1
iNtyp
up
Input Type select
Input A for counting up
Input B for Gate function
down
Input A for counting down
Input B for Gate function
abP-2
A/B Phase x2(double)
idv
Input A for counting up
Input B for counting down
cmd
Input A for counting signal
Input B for counting direction
ry1md
off
Relay 1 action
mode select
Disable
totLn
totLr
totLc
totLe
totLf
totLq
totLl
totLh
N mode
R mode
C mode
F mode
E mode
Q mode
L mode
H mode
aotyp
V0-10
Analog output
type and range
select
0~10 V
V0-5
V1-5
A0-10
A0-20
A4-20
0~5 V
1~5 V
0~10 mA
4~20 mA
0~20 mA
init
Input 7170 to
initialize meter
Next Page
Next Page
Next Page
Key
Go to E-1