Command Interface 30 - 99
Errors-
ERROR TEXT
NUM
DESCRIPTION
ERROR- BAD ARGUMENTS
2
Argument(s) is/are missing or invalid.
ERROR- BAD WHITE LINE
KEY
244
The feature key is either invalid or entered
incorrectly.
ERROR- BAD BYPASS KEY
245
Incorrect Bypass Key
ERROR- BAD SCHEDULING
KEY
246
Incorrect Scheduling Key
ERROR- BAD
NETWORKING KEY
247
Incorrect Networking Key
ERROR- BAD CLOSED
CAPTION KEY
248
Incorrect Closed Caption Key
ERROR- BAD RGB KEY
249
Incorrect RGB Key
ERROR- BAD COMPONENT
KEY
250
Incorrect Component Key
ERROR- BAD GENLOCK
KEY
251
Incorrect Genlock Key
ERROR- BAD SYSTEM KEY
252
Incorrect System Key
Examples-
Operation
-
Display the current FEATURE setting.
<NAME> FEATURE
OK
System= ENABLED
Genlock= ENABLED
Component= ENABLED
RGB= ENABLED
ClosedCaption= ENABLED
Networking= ENABLED
Scheduling= ENABLED
Bypass= DISABLED
Whiteline= DISABLED
<Empty Line>
Operation
-
Set the FEATURE setting for System.
<NAME> FEATURE SYSTEM 123456
OK
<Empty Line>
Products Supported-
Soloist 2, Mirage, and Duet