To begin, you will need to connect to your mediaHUB-HD Pro via ethernet
directly, or by adding the mediaHUB-HD Pro to your local area network.The
default address for all Adtec devices is 192.168.10.48.
To connect directly to the device, make sure that your computer and the
device have IP addresses within the same IP class range (ex. 192.168.10.48 for
the device and 192.168.10.49 for your computer). If you need to change the IP
address of the device, this can be done via the front panel, System > Network
menu. Using a CAT 5 crossover cable, connect one end to your computer and the
other to the Ethernet port found on the processor section of the back panel.
(Some computers can auto negotiate the connection and a crossover may not be
necessary.)
To add the device to a LAN, connect a standard CAT 5 Ethernet cable to
your network router and then to the Ethernet port on the back of the device. If
your network is DHCP enabled and you prefer that over a static IP, you can turn
on DHCP for the device via the front panel, System > Network menu.
Adtec Digital has adopted
zero-configuration networking technology,
streamlining the setup and configuration
processes for our products. The use of this
technology enables automatic discovery of
Adtec devices and services on an IP
network. Used in tandem with the
web-based control and configuration
applications we can now provide 1-click
access to any device.
By using the built-in Bonjour
©
locater in
Apple's
©
Safari
©
browser or the plug-ins
readily available for IE
©
or Firefox
©
browsers,
users can locate all of the Adtec devices on
a network by referencing the serial number
on the back of the device. Clicking on the
unit in the Bonjour
©
list will re-route you to
a login page and you will be prompted for a
username and password. The default
username is ‘adtec’. The default password is ‘none’. If you do not wish to use Bonjour, you can reach
the device web application by pointing your browser to the IP Address of the device. Ex.
http://192.168.10.48.
The left panel of the application will report current status in real-time while the right panel
tabs will allow you to configure your device. Additional hints regarding configuration options can be
found by clicking on the hints buttons associated with each field or group of fields.
Adtec Digital Technical Support: 615.256.6619 www.adtecinc.com
06.22.09
Web-Based Control Application
Getting Connected
Confidence Decode
................................................................................................
ASI IN
Asynchronous Serial Interface per EN500083-9 BNC 75 Ohm.
HD/SD SDI Out
User Defined (D1-1080i). SMPTE
(SD)
259/
(HD)
292 Video and
(SD)
272/
(HD)
299 Audio
HDMI
HDMI v1.3, HDCP v1.2, and DVI v1.0 compliant output.
GigE
MPEG2 or RTP multicast transport egress port (SMPTE 2022)
CVBS Out
75 Ohm terminated NTSC or PAL D1 Composite Video Output
Processor
.................................................................................................................
COM2
API Serial Communication Interface
COM1
Serial Port Used for Troubleshooting
Ethernet
10/100 base T ethernet interface
USB 2.0
Not Currently Supported
Encoder
.....................................................................................................................
ASI OUT
75 Ohm source ASI x3 per EN500083-9
CVBS In
75 Ohm terminated NTSC or PAL D1 Composite Video Input
SDI In
75 Ohm terminated Input, SMPTE
(SD)
259/
(HD)
292 Video and
(SD)
272/
(HD)
299 Audio
AES Audio
75 Ohm AES Audio Input & 75 Ohm Compressed Audio Output (1/2 & 3/4 )
RS422
Sony 9-pin electrical and protocol tape deck interface
GPIO
Tally and Control Port.
Analog Audio In
600 Ohm Balanced Analog Audio Input (1/2 & 3/4)