Connecting to the Adtec edje4000 AVC Encoder
Before you configure your encoder, you will need to establish a connection.
The default IP is 192.168.10.48.
Telnet Connection
To connect to your Adtec edje4000 AVC Encoder using a Telnet connection, attach the unit to your local network and launch a
terminal window. Type telnet and the IPA of the box (ex. telnet 192.168.10.48) and hit enter. Logon with the username "adtec"
and password "none" . Once you are connected, you can begin using the API commands noted in our API documentation to
control your box.
Serial Connection
To use a serial connection with your Adtec edje4000 AVC Encoder , use the terminal kit included with your purchase. This
terminal kit contains a standard ethernet cable and a serial 9 pin adapter. Plug the ethernet cable into the back of your Adtec
edje4000 AVC Encoder using the port labeled COM2. The other end of the ethernet cable should be plugged into the RS232
connector (also part of the terminal kit). The RS232 should then be connected to your computer either directly or with a USB
converter (not included).
Caution: Adtec testers have noted that the use of a USB converter sometimes provides mixed results. A direct connection
with RS232 will serve best. You can use a serial connection utility such as Teraterm or the included eddjeController User
Interface.
Using Teraterm:
PORT: The COM port you select in the application window represents the COM port on your computer that you wish to
communicate from. It is not the COM port number from the back of your unit.
BAUD RATE: The baud rate depends on the connection to the back of the Adtec signEdje. If your terminal kit is connected to
the COM 1 port on the back of the Adtec edje4000 AVC Encoder , your Baud rate is 115200 and you will have access to
diagnostic information. If your terminal kit is connected to the COM 2 port on the back of your Adtec edje4000 AVC Encoder ,
your baud rate will be 38,400. The COM 2 port on the back of the Adtec edje4000 AVC Encoder is used for talking to the
Adtec API.
DATA: Should be set to 8 bit
PARITY: Should be set to none
STOP: Should be set to 1 bit
FLOW CONTROL: Should be set to none.
IP Connection with edjeController
See the section " edjeController" for instructions on downloading the application.
•
See the section " edjeController Window" for connection instructions.
•
Resetting to factory settings
Your Adtec edje4000 AVC Encoder can quickly and easily be reset to the factory default settings.
Using the Boot Key: short pins 2 to 4 on the GPIO header block.
•
Using the Cfg initialize key: short pins 1 to 4 on the GPIO header block.
•