Front Panel

• 8 Button Tactile Raised keypad: 

Mode, Select, Enter, Escape, Up, Down, Left, Right 

• Blue Translucent LCD

20 character by 2 row

• Front Panel Host LED’s

Power, Alarm, Link, Busy, Storage

• Front Panel LEDs

 ASI, SMPTE 310M, Channels 1-12, Alarm

Standards Compliance

• SCTE 30 

Ad Server to Splicer IP based command/control 

protocol

• SCTE 35

Via SCTE 30 from Splicer

Transport private data cueing (requires optional 

ASI input board in lieu of DTF/GPI)

Storage

• 300GB RAID 1

• NAS (software included NAS device and hard drives 

extra)

Inputs

• Gigabit Ethernet

• NAS Compliant Storage Interface

• ASI (10 port ASI input option – replaces DTMF/GPI 

module)

• DTMF/GPI

 

Twelve GPI or GPO

 

Twelve DTMF In

Output Options

• ASI Mirrored (BNC x 3) - 213 Mbps Max 

• Jitter less than 150 (nS)

• PCR, PTS re-stamping

• SMPTE 310M Option (BNCx2) - 19.4 Mbps

Note: Specifications subject to change without written notice

Tables

• MPEG

PAT

CAT (if CA is enabled)

PMT

• DVB (optional with streamer application)

NIT

SDT

TDT/TOT

EIT

• ATSC [Static PSIP – Dynamic with external generator] 

(optional with streamer application)

VCT (Cable or Terrestrial)

MGT

STT

RRT

EIT (1-4)

Table Processing

• User defined management of all PID components or 

tables if required in streamer mode

Host Platform

• PowerPC CPU

• Linux 2.6 Kernel OS (Hardened)

• 10/100 Ethernet RJ-45

• Serial Port (RJ-48)

• USB 2.0

• IEEE 1394 (Firewire)

• GPIO (9 Pin D-sub)

• HTTP, FTP, Telnet, IP Logging, SNMP MIB II and 

private MIB, DHCP, (XCP Adtec encrypted layer 3 

protocol) 

 

Power

• 70-240 VAC switching power supply

• 50/60 Hertz

• Rated at 150 Watts nominal usage 40 watts

Physical

• 19” wide, 1.75” tall, 14” deep

• 1 Rack Unit

Environmental

• Active cooling (Push pull Fans)

• 0 to 90 Degrees Fahrenheit

• Less than 70% RH

• Non-Condensing

© 2006 Adtec Digital. FireWire

® 

is a registered trademark of Apple Computer, Inc. Other product and company names may be trademarks or registered trademarks of their respective companies. 

Power

 

IEEE 1394 FireWire

Terminal Interface

 

Fast Ethernet Interface

USB 2.0 Interface

ASI Redundancy Input

I/O DTMF or GPIO Inputs 1-12

SMPTE Redundancy Input 

ASI Outputs

SMPTE 310 Outputs

RS232

NO-C-NC

GigE 

• 

DPI 1200 Ad Server

• 

DPI Control application control & 

configuration software for Windows 2000/
XP or Macintosh OS X (10.2 or greater).

• 

Connection Kit: power cord, Ethernet 

cable, serial adapter

• 

Manual