– 6 –
SYSTEM OVERVIEW
General Operation
False Alarm Prevention Feature
Note that in cases of alarm, the panel may disarm as soon as the security code is entered, or you can
still enter
CODE
+
OFF
. If your system is connected to a central monitoring station, an alarm message
will be sent. To reduce false alarms, message reporting is delayed 30 seconds. The delay can be reduced
to 15 seconds, or increased up to 60 seconds at your option. Consult with your installer to ensure that
the correct delay has been programmed. To stop the alarm sounding, simply disarm the system. The
zone(s) causing the alarm remain displayed indicating memory of alarm. Refer to the
Disarming the
System
section for information about clearing the memory of alarm display.
Two-Way Voice Feature
The ADT Safewatch
QuickConnect Plus
Security System supports voice dialog between an operator at
the central station and an individual at the premises. This feature allows the central station to listen,
talk to or conduct a two-way conversation with an individual(s) at the premises and allows the operator
to gather information about the nature and location of the alarm that may be helpful in responding to
police or rescue departments. If the Two-way Voice Feature has been programmed and an alarm
condition is detected, the system sends an alarm message to the central station. After
acknowledgement is received, a “listen in to follow” message is sent to the central station. In response
to this message, the central station operator can enter commands that allow him to initiate a 5-minute
voice session. The options allow the operator to enter the following modes:
•
Talk:
Allows the operator to speak to individuals at the premises through the system speaker.
•
VOX (2-way voice):
Allows the operator to hold a two-way (speak and listen) conversation with
individuals at the premises.
•
Listen
: Allows the operator to listen to any activity at the premises through the system microphone.
If a subsequent zone is violated during a voice session, the system will terminate the session and
process the alarm. During the voice session, the ARMED (red) and READY (green) LEDs will