background image

– 10 –

ABOUT THE TOUCHPADS (Continued)

English Display Touchpad

AWAY:  All burglary zones, interior and perimeter, are armed.

STAY: 

Perimeter burglary zones, such as protected windows and
doors, are armed.

INSTANT: 

Perimeter burglary zones armed and entry delay is turned off.

BYPASS: 

This appears when one or more burglary protection zones
have been bypassed.

ALARM
FIRE

AWAY

BYPASS

STAY

CHECK INSTANT 

NO AC

TEST

NOT READY
CHIME   BAT

 

  ENGLISH DISPLAY TOUCHPAD

NOT READY: Appears when burglary portion of the system is not ready for arming (due to open protection zones).

The system is ready to arm when this message disappears and the READY indicator light comes on.

NO AC:  Appears when AC power has been cut off. System is operating on backup battery power.

AC:  Appears when AC power is present.

CHIME:  Appears when the CHIME feature is activated.

BAT:  Low battery condition in a wireless sensor (if zone number displayed) or low system battery (if no

zone number displayed).

ALARM:  Appears when an intrusion has been detected and the system is armed (also appears during a fire

alarm or audible emergency alarm). Accompanied by the protection zone  in alarm.

CHECK: 

Appears when a malfunction is discovered in the system at any time or if an open is detected in a
FIRE zone at any time or a fault in a DAY/NIGHT burglary zone during a disarmed period.
Accompanied by a display of zone number in trouble.

FIRE:  Appears when a fire alarm is present. Accompanied by a display of the zone in alarm.

Содержание Safewatch Pro 2000

Страница 1: ...N7527 5V3 Rev B 1 01 Model SAVS20ADT 1 or SAVS20ADTG UL File No S1632 S Se ec cu ur ri it ty y S Sy ys st te em m User s Manual Safewatch Pro 2000...

Страница 2: ...rly warning fire detection is important in a home Smoke and heat detectors have played a key role in reducing fire deaths in the United States With regard to the number and placement of smoke heat det...

Страница 3: ...MING ALL PROTECTION AWAY 16 DISARMING AND SILENCING ALARMS 17 BYPASSING PROTECTION ZONES 18 Quick Bypass 19 CHIME MODE 20 PANIC KEYS 21 SINGLE BUTTON PAGING FEATURE 22 USING DEVICE COMMANDS 23 PAGING...

Страница 4: ...rammed to automatically send alarm or status messages over the phone lines to a Customer Care Center A Partitioned System Simply stated a partitioned system is a single physical alarm system that prov...

Страница 5: ...personal four digit security code known only to you You must enter the security code when arming and disarming the system and when performing other system functions As an additional safety feature oth...

Страница 6: ...CESS USER S GUIDE which accompanies the voice module Paging Feature If the paging feature has been programmed for your system a pager will respond to certain conditions as they occur in your system Th...

Страница 7: ...the system before the entry delay period ends or an alarm will occur The touchpad beeps during the entry delay period reminding you to disarm the system There are two entry delays if programmed The f...

Страница 8: ...splayed on the touchpad along with a zone number indicating the faulted zone To stop the alarm the system must be disarmed your code plus OFF to clear the display enter your code plus OFF a second tim...

Страница 9: ...nearby safe location There are two basic types of touchpads an English display touchpad and a Custom English display touchpad both described below English display and Custom English display touchpads...

Страница 10: ...tor light comes on NO AC Appears when AC power has been cut off System is operating on backup battery power AC Appears when AC power is present CHIME Appears when the CHIME feature is activated BAT Lo...

Страница 11: ...sed to assign additional user codes for other users of the system 10 9 CHIME KEY Turns CHIME mode on and off When on the opening of windows or doors while the system is disarmed will sound 3 beeps at...

Страница 12: ...chpads shown without swing down front door IMPORTANT When entering codes and commands sequential key depressions must be made within 10 seconds of one another If 10 seconds elapse without a key depres...

Страница 13: ...pass the zones displayed before arming the system The the touchpad s READY indicator light will come on when all protection zones have been either closed or bypassed The system can then be armed if de...

Страница 14: ...isplays below The red ARMED indicator also lights Note that there is an exit delay in effect before arming actually takes place See the note below 3 After arming an alarm sounds immediately if a prote...

Страница 15: ...re arming actually takes place See the note below 3 After arming an alarm sounds immediately if any protected perimeter door or window is opened but you may otherwise move freely throughout the premis...

Страница 16: ...iod to avoid causing an alarm The touchpad will beep rapidly during the last 5 seconds of the exit delay to warn you that the delay is ending After the exit delay expires the system arms and will soun...

Страница 17: ...nd press the OFF key The Ready indicator light will be lit if all zones are secure and the touchpad will emit a single tone to confirm that the system is disarmed To Silence a Burglary Alarm SEE IMPOR...

Страница 18: ...ed to confirm their bypass 4 Arm the system as usual Bypassed zones are unprotected and will not cause an alarm if violated while your system is armed TO BYPASS ZONES Enter code Press BYPASS key Enter...

Страница 19: ...ong with a Bypass message Wait for all bypassed zones to be displayed then arm the system Make sure that only those zones that you wish to leave unprotected are bypassed and that there are no other zo...

Страница 20: ...tivated Pressing the READY key will display the open protection points To turn Chime Mode on Enter the security code and press the CHIME 9 key The CHIME message will appear To turn Chime Mode off Ente...

Страница 21: ...may be connected ALARM plus a zone number is also displayed Activating a personal emergency alarm sends an emergency message to the Customer Care Center and sounds at touchpad s but not at external be...

Страница 22: ...RGENCY FUNCTION AS SHOWN THIS ZONE NUMBER NOT DISPLAYED IF KEY HAS BEEN PROGRAMMED FOR SINGLE BUTTON ARMING ARM AWAY or ARM STAY SINGLE BUTTON PAGING FEATURE The D key on the touchpads can be used to...

Страница 23: ...staller for a full explanation of this feature To activate devices ENTER SECURITY CODE THEN PRESS 7 DEVICE NUMBER 7 Security Code Device Number Example 7 2 9 6 then press then press 7 then enter the n...

Страница 24: ...and closings arming these digits represent the user number In this system the first 2 digits will always be 00 e g 0004 will be displayed for zone number 4 Note that single digit user or zone numbers...

Страница 25: ...system unless the system was armed with this code This code is typically assigned to someone such as a babysitter who has a need to arm disarm the system only at certain times The babysitter code is...

Страница 26: ...epeated from its beginning e g perform steps 1 2 and 3 below with no delay between steps CODE 1 8 Enter master code then press CODE key Master Code Example 7 2 9 6 then press the CODE key 2 Enter user...

Страница 27: ...EADY indicator light should come on if all zones are intact i e all protected windows doors etc are closed AC ENGLISH DISPLAY TOUCHPAD DISARMED READY TO ARM CUSTOM DISPLAY TOUCHPAD TEST 2 5 Enter the...

Страница 28: ...e manufacturer s instructions The identification of each detector should appear on the display when each is activated If a problem is experienced with any protection point no confirming sounds no disp...

Страница 29: ...FF key twice If the display persists CALL FOR SERVICE Note A display of CHECK 70 on English Display touchpads indicates that the wiring connection to the external sounder is at fault opened or shorted...

Страница 30: ...present CALL FOR SERVICE 3 LO BAT zone descriptor Indicates that there is alow battery condition in the wireless or BAT with zone No transmitter number displayed Accompanied by a single beep once eve...

Страница 31: ...ttery for the system has stopped and the system is inoperative CALL FOR SERVICE IMMEDIATELY In The Event Of Telephone Operational Problems In the event of telephone operational problems disconnect the...

Страница 32: ...EMERGENCY DISPLAYS FIRE 05 MASTER BEDROOM 05 ALARM FIRE AC CUSTOM DISPLAY TOUCHPAD ENGLISH DISPLAY TOUCHPAD Silencing Fire Alarms 1 You can silence the alarm at any time by pressing the OFF key the s...

Страница 33: ...s 3 If flames and or smoke are present leave the premises and notify your local Fire Department immediately 4 If no flames or smoke are apparent investigate the cause of the alarm The zone number s of...

Страница 34: ...he National Fire Protection Association s National Fire Alarm Code NFPA 72 noted below Early warning fire detection is best achieved by the installation of fire detection equipment in all rooms and ar...

Страница 35: ...an of the building Show windows doors stairs and rooftops that can be used to escape Indicate escape routes for each room Keep these routes free from obstruction and post copies of the escape routes i...

Страница 36: ...ing Batteries in Wireless Sensors Wireless sensors may not have been used in your security system Each wireless sensor in your system has a 9 volt or 3 volt battery The system detects a low battery in...

Страница 37: ...In the meantime a sensor causing a low battery indication is still fully operational Important Use only batteries recommended by your installer as replacement Routine Care Treat the components of you...

Страница 38: ...til cleared Clear Alarm Memory After disarming enter code again Press OFF key again Touchpad will beep rapidly upon entry if alarm has occurred Alarm display will remain upon disarming until cleared D...

Страница 39: ...BATTERY AT A TRANSMITTER a Opened zone numbers will appear b BAT displayed with zone number of transmitter TWO SHORT BEEPS Touchpad only ARM AWAY AWAY is displayed Red ARMED indicator is lit THREE SHO...

Страница 40: ...W BATTERY AT A TRANSMITTER a Opened Zone identifications will appear b LO BAT displayed with description of transmitter TWO SHORT BEEPS Touchpad only ARM AWAY ARMED AWAY displayed Red ARMED indicator...

Страница 41: ...turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures If using an indoor antenna have a quality outdoor antenna installed...

Страница 42: ...ical the telephone company will notify the customer as soon as possible Also you will be advised of your right to file a complaint with the FCC if you believe necessary The telephone company may make...

Страница 43: ...te tiquette certifie que le mat riel est conforme certaines normes de protection d exploitation et de s curit des r seaux de t l communications Le minist re n assure toutefois pas que le mat riel fonc...

Страница 44: ...Emergency Management Agency Some of the reasons smoke detectors used in conjunction with this System may not work are as follows Smoke detectors may have been improperly installed and positioned Smoke...

Страница 45: ...ises to a central monitoring station may be out of service or temporarily out of service Telephone lines are also subject to compromise by sophisticated intruders Even if the system responds to the em...

Страница 46: ...e normal working hours of ADT are not within the scope of this warranty and any services requested to be performed at such times shall be charged for at ADT s then applicable rates for labor and mater...

Страница 47: ...es you specific legal rights and you may also have other rights which vary from state to state 2 Installation ADT agrees to install the equipment in a workmanlike manner in accordance with the followi...

Страница 48: ...ADT Security Services Inc One Town Center Rd Boca Raton FL 33486 Copyright 2001 N7527 5V3 Rev B 1 01...