About Your Security System

Your DSC Security System has been designed to provide you with the greatest possible flexibility and conve-
nience. Read this manual carefully and have your installer instruct you on your system's operation and on which
features have been implemented in your system. All users of this system should be equally instructed in its use. Fill
out the “System Information” page with all of your zone information and access codes and store this manual in a
safe place for future reference.

NOTE: The PowerSeries security system includes specific false alarm reduction features and is classified with ANSI 
/ SIA CP-01-2000. To comply with this specification, your installation must have a minimum of two keypads. Please 
consult your installer for further information regarding the false alarm reduction features built into your system as all 
are not covered in this manual.

Fire Detection

This equipment is capable of monitoring fire detection devices such as smoke detectors and providing a warning
if a fire condition is detected. Good fire detection depends on having adequate number of detectors placed in
appropriate locations. This equipment should be installed in accordance with NFPA 72 (N.F.P.A., Batterymarch
Park, Quincey MA 02269). Carefully review the Family Escape Planning guidelines in this manual.

NOTE: Your installer must enable the fire detection portion of this equipment before it becomes functional.

Testing

To insure that your system continues to function as intended, you must test your system weekly. Please refer to
the “Testing your System” section in this manual. If your system does not function properly, call your installing
company for service.

Monitoring

This system is capable of transmitting alarms, troubles & emergency information over telephone lines to a central
station. If you initiate an alarm by mistake, immediately call the central station to prevent an unnecessary response.

NOTE: The monitoring function must be enabled by the installer before it becomes functional.
SIA NOTE: There is a communicator delay of 30 seconds in this control panel. It can be removed, or it can be in-
creased up to 45 seconds, at the option of the end-user by consulting with the installer.

Maintenance

With normal use, the system requires minimum maintenance. Note the following points:

• Do not wash the security equipment with a wet cloth. Light dusting with a slightly moistened cloth should 

remove normal accumulations of dust.

• Use the system test described in “Testing Your System” to check the battery condition. We recommend, how-

ever, that the standby batteries be replaced every 3-5 years.

• For other system devices such as smoke detectors, passive infrared, ultrasonic or microwave motion detectors or 

glassbreak detectors, consult the manufacturer’s literature for testing and maintenance instructions.

General System Operation

Your security system is made up of a DSC control panel, one or more keypads and various sensors and detectors.
The control panel will be mounted out of the way in a utility closet or in a basement. The metal cabinet contains
the system electronics, fuses and standby battery. 

NOTE: Only the installer or service professional should have access to the control panel. 

All the keypads have an audible indicator and command entry keys. The LCD keypad has an alphanumeric liquid
crystal display (LCD). The keypad is used to send commands to the system and to display the current system status.
The keypad(s) will be mounted in a convenient location inside the protected premises close to the entry/exit door(s). 

The security system has several zones of area protection and each of these zones will be connected to one or
more sensors (motion detectors, glassbreak detectors, door contacts, etc.). A sensor in alarm will be indicated a
written messages on the LCD keypad. 

Содержание PremisePro LCD5500Z

Страница 1: ...This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer The entire manual should be carefully read Use...

Страница 2: ......

Страница 3: ...uous Siren 8 Fire Alarm Pulsed Siren 8 Time Date Programming 8 Bypassing Zones 8 Trouble Conditions 10 Trouble Menu Acknowledgement 10 Alarm Memory 10 Door Chime Entry Exit Beeps 10 Access Code Progra...

Страница 4: ...ipment is of a type that is not intended to be re paired by the end user DSC c o APL Logistics 757 Douglas Hill Rd Lithia Springs GA 30122 Additional Information Connection to party line service is su...

Страница 5: ...1 System Keypads Trouble Ready Armed LCD5500Z Keypad LCD5501Z Keypad Trouble Ready Armed 1 2 3 4 5 6 7 8 0 9 Stay Away Chime Reset Bypass PK5500 PK5501...

Страница 6: ...ning of the Exit Delay 9 Fire Indicates that there are fire alarms in memory 10 Stay Indicates that the panel is armed in the Stay Mode It will turn on at the beginning of the Exit Delay 11 Chime This...

Страница 7: ...19 28 02 11 20 29 03 12 21 30 04 13 22 31 05 14 23 32 06 15 24 33 Duress 07 16 25 34 Duress 08 17 26 09 18 27 The Entry Delay Time is _______ seconds The Exit Delay Time is _______ seconds For Servic...

Страница 8: ...Area Sensor Type Sensor Protected Area Sensor Type 01 33 02 34 03 35 04 36 05 37 06 38 07 39 08 40 09 41 10 42 11 43 12 44 13 45 14 46 15 47 16 48 17 49 18 50 19 51 20 52 21 53 22 54 23 55 24 56 25 57...

Страница 9: ...ntral station If you initiate an alarm by mistake immediately call the central station to prevent an unnecessary response NOTE The monitoring function must be enabled by the installer before it become...

Страница 10: ...lease check with your installer to have this time programmed To cancel the arming sequence enter your access code Away Arming Turned On Set When the exit delay is completed the alarm system is armed s...

Страница 11: ...as long as the Away Arming Exit Delay Night Arming To fully arm the system when it has been armed in Stay Mode press 1 at any keypad All interior zones will now be armed except for devices programmed...

Страница 12: ...e the zone bypassing feature when you need access to a protected area while the system is armed or when a zone is temporarily out of service but you need to arm the system Bypassed zones will not be a...

Страница 13: ...and return to the Ready state press Bypass Groups A Bypass Group is a selection of zones programmed into the system If you bypass a group of zones on a regular basis you can program them into the Bypa...

Страница 14: ...you can program up to 32 additional User Access codes Press plus your Master Access Code The Program or System indicator will begin to flash and the Armed indicator will turn on Enter the 2 digit num...

Страница 15: ...ill transmit the Duress Reporting Code whenever the code is entered to perform any function on the system NOTE Duress codes are not valid when entering 5 6 or 8 sections NOTE No codes can be programme...

Страница 16: ...3 Partition Three Access 4 Partition Four Access 5 Partition Five Access 6 Partition Six Access 7 Partition Seven Access 8 Partition Eight Access Notes on Access Codes and Programming 1 There will st...

Страница 17: ...the panel s standby battery 5 Enable DLS Allow System Service If enabled the installer will be able to access Installer Programming by DLS In case of DLS access this provides a window where rings wil...

Страница 18: ...e keypad will allow you to scroll through 21 different buzzer levels A level of 00 disables the buzzer 1 Press Master Code 2 Use the keys to scroll to Buzzer Control 3 There are 21 different levels us...

Страница 19: ...event buffer viewing press PK5500 Global Status Screen When the keypad is loaned to global mode pressing and holding the key you will see a Global Partition Sta tus screen This shows basic status for...

Страница 20: ...ow or walk in motion detector areas PK5500 LCD5500 keypads will display the following message when each zone detector is activated Secure System Before Arming Secure System or Enter Code or Secure or...

Страница 21: ...etc Consult National Fire Alarm Code NFPA 72 CAN ULC S553 M86 or other appropriate national standards for installation recommendations Do not locate smoke detectors at the top of peaked or gabled cei...

Страница 22: ...indows are easily opened Ensure that they are not painted shut and that their locking mechanisms operate smoothly If opening or using the exit is too difficult for children the elderly or handicapped...

Страница 23: ...adversely affect performance or prevent adequate inspection or testing to ver ify any warranty claim Access cards or tags returned for replacement under warranty will be credited or replaced at DSC s...

Страница 24: ...ors that are a part of this system may not properly alert occupants of a fire for a number of reasons some of which follow The smoke detectors may have been improperly installed or positioned Smoke ma...

Отзывы: