background image

User Guide

 8

  Galaxy 8/18/60/500/512

OMIT ZONES (User Level 3 and above)

PURPOSE

This option allows the user to omit zones before setting the system.
Zones must be eligible for omission otherwise they will not be
displayed.

NOTE:

 Zones remain omitted for one set period only.

SELECTING OMIT ZONES

Enter the QUICK MENU. The 0=OMIT ZONES option is displayed.
Press the ent key to select this option.

VIEWING ELIGIBLE ZONES

When the OMIT ZONES option is selected the first zone eligible for
omission is displayed. The eligible zones can be viewed by pressing
the A> or <B keys. The zones eligible for omission can be rapidly
viewed by holding down either of these keys.

OMITTING ZONES

Once the zone to be omitted is shown on the display, press the # key.
The display indicates that the zone is omitted. A> and <B keys can
then be used to select other zones to be omitted using the same
method.

NOTE:

A zone is omitted from the system as soon as the key is
pressed. The system does not have to be set for this to
come into effect.

SETTING WITH OMITTED ZONES

When the list of omitted zones is complete the setting routine is
started by pressing the ent key. The system starts to set and the
display indicates how many zones have been omitted. Alternatively
the esc key can be used to return to the menu options. Zones that
have been omitted remain omitted even after using the esc  key.

NOTE:

All zones omitted are recorded in the log against the user.

GALAXY 512

The Galaxy 512 will allow a single eligible zone to be omitted from
the system. Once a zone has been omitted, it is not possible to view
other zones with  the omit attribute enabled, until the omitted zone is
reinstated (either automatically or manually).

ZONES OMITTED

14:35 TUE 17 DEC

1 OMITTED

120

ent

#

ent

1004 SECURITY 

OMITTED ENT=SET

0 = OMIT ZONES

[ent] to select

PIN + ent

1003 INTRUDER 

#=OMIT ENT=SET

ent

1004 SECURITY 

#=OMIT ENT=SET

>A

Technical Manuals Online! - http://www.tech-man.com

Содержание Galaxy 18

Страница 1: ...Galaxy 8 18 60 500 512 User Guide 9 3 6 8 0 2 5 7 1 4 A ent esc B Galaxy 512 V1 15 11 42 TUE 11 OCT Technical Manuals Online http www tech man com...

Страница 2: ...Technical Manuals Online http www tech man com...

Страница 3: ...ing from the Entry Route 5 Slow Entry 5 Cancelling Alarms 5 Manager Reset 5 Engineer Reset 5 Menu Options 6 Accessing the Menu 6 Full Menu 6 Quick Menu 6 Quick Menu Options Table 7 Omit Zones 8 Omitti...

Страница 4: ...odes 15 Modify PIN 16 Dual Codes 16 Modify Level 17 Duress Code 17 Modify Name 18 Time Zone 18 Temporary Codes 19 PIN Change Codes 19 Modify Groups 20 Group Choice 21 MAX Number 21 MAX Function 22 MAX...

Страница 5: ...act a computer which has been designed using the latest software and hardware technology First and foremost the Galaxy meets all your security needs The engineer will program and commission the system...

Страница 6: ...used where groups are programmed on the system permitting groups areas to be set or unset VIEW KEYS A and B These keys have been programmed to activate one of the system options Pressing the A key aft...

Страница 7: ...following a valid code entry STAR KEY T T T T T The T key is used to provide additional features for certain options e g printing the event log or deleting entries POWER LED The green power LED remain...

Страница 8: ...screen Select which groups have to be to set by entering the number of the group For example to set groups 2 and 3 press keys 2 and 3 The display changes to indicate the groups selected for setting P...

Страница 9: ...ual termination is made the system waits four seconds before setting The sounders emit two long tones to confirm that the system is set The keypad briefly displays the message SYSTEM SET before becomi...

Страница 10: ...e quickly when 75 of the entry time has elapsed indicating time is running short CANCELLING ALARMS To cancel an alarm enter a valid PIN followed by ent at the keypad The keypad displays the details of...

Страница 11: ...e all groups assigned to the user code must be unset 2 If the user has group choice at least one group on the system must be unset 3 If there are no groups then the system must be unset FULL MENU The...

Страница 12: ...1 3 5 e t a D e m i T 7 1 4 6 s e d o C 8 2 4 6 r e m m u S 9 3 4 6 t e S d e m i T 2 1 3 t e S t r a P 3 1 3 t e S t n a t s n I 6 1 3 t r a P t n a t s n I 7 1 3 t e S e m o H 8 1 3 t e S l l A 9 1...

Страница 13: ...g the same method NOTE A zone is omitted from the system as soon as the key is pressed The system does not have to be set for this to come into effect SETTING WITH OMITTED ZONES When the list of omitt...

Страница 14: ...ORCED SET User Level 3 and above PURPOSE The FORCED SET option allows the user to automatically omit zones eligible for omission which are open when the system setting routine is started Zones omitted...

Страница 15: ...chime attribute by the engineer continue to chime when they are activated Note The CHIME mode is suspended while the system is set or during an alarm DISPLAY ZONES User Level 4 and above PURPOSE This...

Страница 16: ...ce and RIO voltage ESCAPE The esc key aborts the option and returns to the option menu DISPLAY LOG User Level 4 and above PURPOSE DISPLAY LOG provides the user with a means of viewing the system histo...

Страница 17: ...stem print options are displayed Pressing the esc key aborts the PRINT option CODES Press key 1 to start the print out of all the codes giving the user number name level and length of code ZONES Selec...

Страница 18: ...and stops when all zones are closed NOTE The TEST ALL ZONES option only tests zones which can be omitted from the system SELECTED ZONES Choosing the SELECTED ZONES option by pressing key 2 displays th...

Страница 19: ...invalid dates e g 14 12 99 Pressing the esc key aborts the entry ADVANCE AND RETARD It is possible to advance and retard the time to compensate for any variations in clock speed Press the key when in...

Страница 20: ...Assign the MAX features to the code The manager code defaults to group choice when groups are enabled The manager is able to toggle the group choice option on and off using the T key as required GALA...

Страница 21: ...s displayed in the top line of the users details screen ASSIGNING DUAL CODES To program a user code as a Dual Code press the key while the Modify PIN option is selected The displays at the start of th...

Страница 22: ...e s y l n o n a C 2 r e k a t e r a C m e t s y s e h t t e s n u d n a t e s y l n o n a C 3 s r e s U 9 1 1 1 s n o i t p O u n e M 4 s r e s U 9 2 1 1 s n o i t p O u n e M 5 s r e s U 9 3 1 1 s n...

Страница 23: ...lt or previous name When the previ ous name has been erased use the A or B keys to move the cursor to the first letter of the name and press the ent key The selected character appears on the top line...

Страница 24: ...Warning option This prompts the user to assign a new code whenever the expiring code is entered during the PIN Warning period except during system unsetting The new PIN must be six digits and must be...

Страница 25: ...s have been assigned to the user press the ent key to accept the programming and return to the previous menu level GALAXY 500 and 512 The Galaxy 500 has 16 groups and the 512 has 32 groups The groups...

Страница 26: ...to group 4 cannot assign group 4 to another user code MAX NUMBER Each MAX card has a unique 10 digit number laser etched onto it A MAX card is assigned to a user by entering this number in the MAX Num...

Страница 27: ...used CARD HELD MAX OPERATION The MAX function is activated when the card is held directly in front of a MAX reader for three seconds The MAX reader must be assigned a common group to the MAX user The...

Страница 28: ...display the first MAX user number User 201 Each of the users can be displayed using the A and B keys or a specific user can be selected by entering the required user number When the required code is...

Страница 29: ...d on the keypad in blocks of eight groups labelled A B C and D Use the A or B keys to move between the group blocks Press keys 1 8 to assign the groups in each block to the user SUMMER User Level 6 On...

Страница 30: ...tems These should be switched off if possible 4 Always follow the exit entry route procedure agreed with your alarm installer 5 Treat the alarm components with care to ensure they are not damaged 6 Co...

Страница 31: ...c n u F n o i t p i r c s e D e m i h C t i m O t r a P 1 2 3 4 5 6 7 8 1 1 0 1 2 1 0 1 3 1 0 1 4 1 0 1 5 1 0 1 6 1 0 1 7 1 0 1 8 1 0 1 e n o Z n o i t c n u F n o i t p i r c s e D e m i h C t i m O...

Страница 32: ...set the alarm Tamper alarms usually require an engineer to visit the site to check all modules on the system This message is displayed when a tamper alarm occurs NO ENTRIES This message appears if a u...

Страница 33: ...User Guide 28 Galaxy 8 18 60 500 512 Name Address Telephone Office Hours Other Times Account No INSTALLER DETAILS Technical Manuals Online http www tech man com...