VMT9000 series
−
Instruction manual v1.9
33
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany
6.4.1 IGN function
Note: The basic operation of the IGN function is described in section 5.4.2.
The following applies to devices with IGEL Linux:
a) The device always starts with a rising edge at the IGN input.
b) Optional: the device shuts down in the case of a falling edge; see registry key
Registry/Parameter/devices/ads_tec_vmt9/ignition_shutdown
c) Optionally, you can parametrize a waiting period between a falling IGN edge and the shutting down
of the device:
Registry/Parameter/devices/ads_tec_vmt9/minute_to_shutdown
Note: Only enter whole minutes; decimal places will be ignored.
Note: A waiting time of 5 s must be complied with prior to a restart after shutdown so that the IGN input
reliably detects a new rising edge.