background image

00 

 

 

 

 
 
 
 
 
 
 

Instruction manual 

Industrial router & firewall 
IRF1000 series 

 
 
 
 

 

Translation of the original 

instruction manual  

Version 1.3 

 

Updated 2020-09-15

 

Содержание IRF1000 Series

Страница 1: ...00 Instruction manual Industrial router firewall IRF1000 series Translation of the original instruction manual Version 1 3 Updated 2020 09 15...

Страница 2: ...ating and safety instructions 10 3 1 Safety instructions 11 3 2 Operating location 11 3 3 Damage due to improper use 11 3 4 Warranty repairs 12 3 5 Intended use 12 3 6 Improper use 12 3 7 Safety instr...

Страница 3: ...ehaviour of the status displays when resetting to default settings 22 6 2 3 Behaviour of the status displays during the firmware update 22 6 3 Interface overview 23 6 3 1 24 VDC power supply 23 6 3 2...

Страница 4: ...g and may differ from the actual design The operator operating company is independently responsible for compliance with and observance of any subsequently introduced technical innovations or new legal...

Страница 5: ...re decisive to device setup and operation This instruction manual contains information for installation commissioning and operation of the device along with technical data of the device hardware Techn...

Страница 6: ...hazard Source of hazard Measures to prevent hazard 2 2 Graduation of risk level The signal word classifies the hazard Instructions for preventing the hazard are identified by an arrow 2 3 Explanation...

Страница 7: ...ely Used batteries must be returned to the point of sale or a disposal system Label on electrical and electronic devices Electrical and electronic devices must not be disposed of with household waste...

Страница 8: ...trademarks used are hereby acknowledged In the case of infringement of trademark rights ADS TEC reserves the right to exercise all rights 2 7 Copyright This instruction manual is protected by copyrig...

Страница 9: ...lso be compliant with these requirements It is therefore necessary to employ BUS and LAN cables with shielded connectors and these must be installed as per the instructions contained in the instructio...

Страница 10: ...o prevent electrostatic discharges on components If the device is opened up by an unauthorised person the user may be subject to hazards and the warranty is invalidated General information Installatio...

Страница 11: ...nmental conditions are maintained at all times Use in non specified environments i e on board ships in explosive atmospheres or at extreme elevations is prohibited See also chapter 8 Technical data AT...

Страница 12: ...ufacturer s declaration are necessary e g applications with explosion hazard medical technology shipping industry The device must not be put into operation in the case of transport damage or nonconfor...

Страница 13: ...entional startup WARNING Communication via wireless connections cannot be guaranteed The device must not be used for applications in which people could be injured or objects damaged due to interferenc...

Страница 14: ...ical qualifications Per the requirements of the U S Federal Communications Commission FCC and the Canadian ISED Industry Canada the antenna gain including power losses must not exceed the following va...

Страница 15: ...device according to UL approval Indoor use only The communication cables may only be installed inside a building or a maximum of 42 7 m 140 feet outside buildings The device contains an internal fuse...

Страница 16: ...provides safe access for service purposes 4 1 Equipment versions Version WAN LAN 4G LTE IRF1401 RJ45 RJ45 IRF1421 RJ45 RJ45 x 4 2 Digital input In critical commissioning or production phases the Ether...

Страница 17: ...3 pin plug for RS 485 1 x Quick start guide Optional 1 x Mobile communications antenna 4 6 Environmental conditions The device can be put into operation and used under the following conditions Failure...

Страница 18: ...IRF1000 series Instruction manual v1 3 18 ads tec Industrial IT GmbH Heinrich Hertz Str 1 72622 N rtingen Germany 5 Installation 5 1 External device dimensions...

Страница 19: ...above onto the top hat rail and remove the screwdriver 3 The top hat rail locking mechanism springs back to its original position 4 Check that the IRF is seated securely on the top hat rail To release...

Страница 20: ...rtingen Germany 6 System features 6 1 General LED status displays The integrated LEDs indicate the status of the various interfaces This makes diagnosis possible at the installation site LED status Re...

Страница 21: ...ated LED flashes rapidly 5 Hz The device is ready for operation Status This device is not supplied with voltage Error during the boot up process recovery image VPN No VPN tunnel is active The tunnel a...

Страница 22: ...settings the Factory Default button must be pressed prior to the boot up process and held down for approx 10 seconds during the boot up process The PWR LED flashes rapidly while resetting to factory...

Страница 23: ...acc to IEC 62368 1 or Limited Power Source LPS acc to IEC 60950 1 For devices with UL Certification NEC Class 2 Voltage 24 VDC 20 Short circuit current 8 A Informations on using the device acc to UL...

Страница 24: ...for mobile communications must be inserted into the top slot SIM1 The smart card is intended for backing up the configuration data or for connecting to Big LinX and must be inserted into the bottom s...

Страница 25: ...Connecting the 24 VDC power source The device can be supplied via a 24 VDC power source The corresponding plugs are included in the scope of delivery 4 pin plugs Connect the device with the appropriat...

Страница 26: ...s right mouse key In the dialogue tab that appears select option Internet protocol TCP IP and then click on Properties In the following window select Use the following IP address Access to the device...

Страница 27: ...nal limitations if a different browser is used To access and open the device web interface start up your web browser In the browser s address bar enter the following IP address and then confirm with E...

Страница 28: ...nnection cable Otherwise connect the device to a PC Device LAN connection PC LAN connection If there is still no connection to the firewall login screen check the proxy and local firewall settings Oft...

Страница 29: ...t Approx 0 2 kg Protection class IP30 tested by ADS TEC not evaluated by UL Over voltage category I as per DIN EN 60664 1 max 1500 V Pollution degree 2 as per IEC 61010 1 Altitude during operation 200...

Страница 30: ...hese specific configurations and software installations please contact them as ads tec will not be able to answer such questions ADS TEC does not provide support services for any device that was not p...

Отзывы: