Duo-i6525 RF Repeater
User Manual V1.0
2.2.
Operation Modes
2.2.1.
Local Web GUI
Simply connect one end of the ethernet cable on the repeater monitor port and
the other end on the PC’s LAN port. After doing so, launch the Microsoft
Internet Browser (Internet Explorer) and the Local Web GUI will be launched
through typing the IP address (
http://192.168.63.1/home.asp
)
2.2.2.
Remote NMS (Modem Option)
A CDMA wireless modem can be integrated within a Duo-i6525 repeater.
With this wireless modem, the user can remotely log into the repeater for
monitoring purposes.
2.3.
Components
2.3.1.
2.3.1 Power Supply
It provides DC power to each module within the repeater.
2.3.2.
Controller
It is responsible for monitoring the status of each module and controls its
parameters. If a CDMA wireless modem is integrated within the repeater, it
also handles the remote “Command & Control” feature as well.
2.3.3.
Down Converter Module
The downlink RF signal entered through the cavity filter is converted to IF
frequency, which is later converted back to RF frequency again through digital
filtering. The downlink HPA (high power amplifier) is integrated with the
Down Converter Module.
2.3.4.
Up Converter Module
The uplink RF signal entered through the cavity filter is converted to IF
frequency, which is later converted back to RF frequency again through digital
filtering. The uplink HPA (high power amplifier) is integrated with the Up
Converter Module.
Advanced RF Technologies, Inc. Proprietary Document
Page 10 of 31