13. Click
Apply Settings
.
The module will restart, and will then become available with the new IP settings. You can change the IP
address in the address bar, or you can use the search function as before.
14. Repeat steps 4 to 13 for other IP modules.
Now you can connect the IP modules to the PIR detectors.
14.8.3
Connecting the IP Modules to the PIR Detectors
For details on connecting the IP modules to the PIR detectors, see the document
ADPRO PRO E-IPM Legal
Disclaimer & Intended Use of Product
(27556).
Take into account that the wire colours may be different:
A
Blue
Red
B
Black
Orange
+
Brown
Yellow
GND
Red
Green
After connecting the IP modules to the PIR detectors, you can add the IP modules in the XO client. For details,