9. SPECIFICATION:
MODEL
Micro PC 300
Micro PC 600
Internal UPS
(Hi Frequency)
CAPACITY
(Computer Load)
300VA / 180W
400VA / 240W
INPUT
Voltage
100V/110V/115V/220V/230V/240V
±
15%
Frequency
50Hz/60Hz
Auto
detect
OUTPUT Voltage
100V/110V/115V/220V/230V/240V
±
5%
for Back-up Mode
Frequency
50Hz or 60Hz ± 0.1Hz
Wave Form
Simulated Pseudo Sine Wave
Runtime of one set of P.C.
(Including 15” LCD monitor)
10 minutes Typical.
30 minutes Typical.
TRANSFER TIME
4ms Typical.
BATTERY
Maintenance Free
Lead-Acid
Ni-MH
Voltage/Capacity
6V 3Ah x 2pcs
1.2V 3.5Ah x 15pcs
Recharge Time
Approx. 8 hrs to 90%
Approx. 21 hrs to 90%
LED/ALARM INDICATION
Normal/
In charge
GRN LED, No Beep.
Back up / Abnormal Input Voltage
RED LED Flashing, 2 Beeps / 4 sec.
Power Saving
(When No Load)
RED LED Flashing,1 Beep / 4 sec.
(Auto off in 30 sec.)
Low Battery
RED LED Flashing, 4 Beeps / sec.
Battery Replacement
RED LED Flashing, 8 Beeps/ sec.
Over Load/Fault
RED LED Flashing, Continuous Beep.
Abnormal Input Frequency
(Back up)
RED LED Flashing, No Beep.
OPERATION TEMP.
0-40
℃
OPERATION HUMIDITY
30-95% Non-Condensing
DIMENSIONS (L*H*W)
242 x 144 x 40(mm)
242 x 144 x 40(mm)
WEIGHT
(N.W./G.W. KG)
3 .5/ 3.5 (kgs)
3.5 / 4.0 (kgs)
U P S
Uninterruptible Power System
User's Manual
INTERNAL TYPE
(Micro PC series)
Advanced Power Systems GmbH & Co. KG, Bayreuther Str. 6, D-91301 Forchheim
Phone: +49(0)9191-7005-0, Fax: +49(0)9191-7005-20, www.adpos-ups.de
Micro PC series
Micro PC series
7