background image

1

2

3

ADP QuickPunch

Finger

 

Scan Verification Device

Installation Guide

The ADP QuickPunch

®

 finger scan verification device allows 

you to require employees to perform verification when they 
swipe a badge or enter their personal identification number 
(PIN) at the Series 4000 timeclock. To use the verification 
devices, Your ADP host system must include the ADP Quick-
Punch software.

When you attach the finger scan verification device to the Series 
4000 timeclock, the device  must lie

 

flat

 

against the mounting 

surface.

Tools You Will Need  

Determining the Part Number of the Timeclock

Important

If the part number of the timeclock is 8602000-4xx

, you 

cannot 

mount the 

timeclock with the finger scan verification device away from an AC outlet. You must 
mount the timeclock over (covering) an AC outlet or use an internal AC outlet. Also, 
the finger scan verification device connects differently to the main board in the 
timeclock depending on the part number of the timeclock. 

Determine the part number of the timeclock in either of the following ways: 

• Look at the bar code label on the bottom of the timeclock (the underside of the time-

clock as you look at the display and keypad). The part number is directly above the 
bar codes.

• If the Series 4000 timeclock uses firmware version 2.0 or higher, access Mainte-

nance mode at the timeclock and run the Hardware Report. The part number of the 
timeclock is included in the report output on the screen. For more information about 
the Hardware Report, refer to the 

Series 4000 Timeclock User’s Guide

.

Preparing for the Installation

Do the following 

only if

 you are adding the ADP QuickPunch verification device to an 

installed and assembled Series 4000 timeclock. Otherwise, go directly to 

“Installing and 

Connecting the Verification Device”

 to begin the installation.

1. Use the security wrench to loosen the security screw on the right side of the timeclock 

and open the cover.

2. Inside the timeclock, 

unplug the power cord from the electrical outlet.

3.

Perform this step only if there is a backup battery installed in the timeclock.

 

a. Tilt the battery out of its position by pushing up on the top bracket (1) and pulling 

the top of the battery outward.

b. Disconnect the 

black

 wire from the negative battery terminal (2). Then, disconnect 

the 

red

 wire from the positive battery terminal (3) and remove the battery.

Installing and Connecting the Verification Device

1. Refer to the next illustration to see if there is a black plate covering the right square 

cable access hole (1) in the bottom of the timeclock. If there is a plate, use a 1/4 inch
(6.35 mm) wrench to remove the two nuts on the screw posts, and remove the plate.

2. To attach the device to the timeclock:

a. Thread the device’s cable and ground wire (1) into the timeclock through the square 

access hole and align the screw holes in the device with the holes in the base of the 
timeclock.

b. Install the two mounting screws (2) using a No. 2 Phillips screwdriver. If necessary, 

slide the transformer (3) up slightly so that you can more easily install the screws. 

 

3.

If the part number of the timeclock is

 

8602004-4xx or 8602800-4xx

, plug the cable into 

the RS-232 connection on the main board:  

If the part number of the timeclock is

 

8602000-4xx

, plug the cable into the RS-232 

connection on the main board:  

4. Ground the verification device by attaching the green ground wire to the main board of 

the timeclock. Where you attach the ground wire depends on the timeclock model and 
which optional devices are installed in the timeclock.

Warning

: Failure to attach the ground wire to the main board will result in damage to 

the finger scan verification device. 

Document Part Number: 4703858-002
Document Revision: B

No. 2 Phillips 
screwdriver 

Security wrench 
(ships with Series 4000 

Pliers or 1/4 inch 
(6.35 mm) wrench

1