Suzhou Alston D.M Laser Technology Co., Ltd
DemonMao
8
3.3.2 Use steps:
Step 1: Button operation, as shown in Figure 3.
1) Reset the "Emergency Stop" button;
2) 2) Turn the "Power" key switch to the right, turn on the power of the control system, and the
green "Indicator" is on;
3) Press the "Laser" button, the "Laser" green button lights up
Step 2: Open the cabinet and turn on the laser, as shown in Figure 4.
1) Check whether the "LASER" button is reset, if it is not reset, please reset the "LASER"
button; reset the "Emergency stop" button;
2) Turn the "Power" key switch to the right, and the "POWER" green indicator light is on;
3) After the green indicator light is on for 10 seconds, press the "LASER" button, and the
"LASER" red indicator light is on; Note that if the "ALARM" indicator light is on, the laser is in
alarm state, please turn off and contact the Laser Research Institute.
Step 3: Open the upper cover of the case and take out the cleaning head, as shown in Figure 5. It is
forbidden to face the cleaning head towards people, and it is forbidden for the laser output head to
irradiate the surface of highly reflective materials (such as copper, aluminum, mirror stainless steel