62
Operation Theory
4.6 Trigger Sources
The PCI-9222/PCI-9223 supports two trigger sources for analog
input, analog output, and digital waveform acquisition/generation:
software trigger and external digital trigger.
Software Trigger
This trigger mode does not need any external trigger source. The
trigger asserts right after you execute the specified function calls
to begin data acquisition.
External Digital Trigger
An external digital trigger occurs when a rising edge or a falling
edge is detected on the digital signal connected to the PCI-9222/
PCI-9223 function I/O. You can set any DI line as external trigger
pin. You may also easily program the trigger polarity via the
ADLINK software drivers. Take note that the signal level of the
external digital trigger signals should be TTL-compatible with a
minimum 25 ns pulse.
NOTE
Digital waveform acquisition/generation only supports
rising-edge trigger. You can not set the polarity using the
software driver.
Figure 4-37: External Digital Trigger