9
I/O port
Address(Hex)
1
A8
2
A7
3
A6
4
A5
5
A4
200-20F
ON
(0)
ON
(0)
ON
(0)
ON
(0)
ON
(0)
210-21F
ON
(0)
ON
(0)
ON
(0)
ON
(0)
OFF
(1)
220-22F
(default)
ON
(0)
ON
(0)
ON
(1)
OFF
(1)
ON
(0)
230-23F
ON
(0)
ON
(0)
ON
(0)
OFF
(1)
OFF
(1)
:
300-30F
OFF
(1)
ON
(0)
ON
(0)
ON
(0)
ON
(0)
:
3F0-3FF
OFF
(1)
OFF
(1)
OFF
(1)
OFF
(1)
OFF
(1)
Table 2.2 Possible Base Address Combinations
A0, ..., A9 is corresponding to PC Bus address lines
A9 is always set as “1”.
How to define the base address for the ACL-8216 ?
The DIP1 to DIP6 in the switch SW1 are one to one corresponding
to the PC bus address line A8 to A4. A0~A3 are always 0, and A9 is
always 1. If you want to change the base address, you can only
change the values of A8 to A4 (the shadow area of below table). The
following table is an example, which shows you how to define the
base address as
Hex 220
Base Address:
Hex 220
2
2
0
1
0
0
0
1
0
0
0
0
0
A9
A8
A7
A6
A5
A4
A3
A2
A1
A0
Содержание NuDAQ ACL-8216
Страница 1: ...N u D A Q ACL 8216 16 bit High Resolution Data Acquisition Card User s Guide...
Страница 3: ......
Страница 7: ......
Страница 14: ...Installation 7 Figure 2 1 PCB Layout of the ACL 8216...
Страница 17: ...10 Installation...
Страница 27: ......
Страница 45: ......
Страница 55: ...48 C C Library...
Страница 58: ...C C Library 51...
Страница 62: ...C C Library 55 int count int ad_buffer unsigned int c1 unsigned int c2...
Страница 65: ...58 C C Library...
Страница 71: ......
Страница 75: ......
Страница 77: ......