24
Interface Signals
P147
VDD_IN (Module power input voltage -
3.0V min to 5.25V max)
S148
LID# (Lid open/close indication to Module.
Low indicates lid closure, which system
may
use to initiate a sleep state. Carrier to float
the line in inactive state. Active low, level
sensitive. De-bounced on the Module
Pulled up on Module.
Driven by OD part on Carrier.)
P148
VDD_IN (Module power input voltage -
3.0V min to 5.25V max)
S149
SLEEP# (Sleep indicator from Carrier
board; sourced from user Sleep button or
Carrier logic. Carrier to float the line in
inactive state. Active low, level sensitive;
de-bounced on the Module.
Pulled up on Module.
Driven by OD part on Carrier.)
P149
VDD_IN (Module power input voltage -
3.0V min to 5.25V max)
S150
VIN_PWR_BAD# (Power bad indication
from Carrier board. Module
and Carrier power supplies (other than
Module and Carrier power supervisory
circuits)
is not
enabled while this signal is
held low by the Carrier.
Pulled up on Module.
Driven by OD part on Carrier.)
P150
VDD_IN (Module power input voltage -
3.0V min to 5.25V max)
S151
CHARGING# (Held low by Carrier during
battery charging. Carrier to float the line
when charge is complete. Pulled up on
Module. Driven by OD part on Carrier.)
P151
VDD_IN (Module power input voltage -
3.0V min to 5.25V max)
S152
CHARGER_PRSNT# (Held low by Carrier if
DC input for battery charger is present.
Pulled up on Module. Driven by OD part on
Carrier.)
P152
VDD_IN (Module power input voltage -
3.0V min to 5.25V max)
S153
CHARGER_STBY# (The Module drives this
signal low when the system is in a standby
power state)
P153
VDD_IN (Module power input voltage -
3.0V min to 5.25V max)
S154
CARRIER_PWR_ON (Carrier board circuits
[apart from power management and power
path circuits]
are
powered up until the
Module asserts the CARRIER_PWR_ON
signal)
P154
VDD_IN (Module power input voltage -
3.0V min to 5.25V max)
S155
FORCE_RECOV# (Low on this pin allows
non-protected segments of Module boot
device to be rewritten / restored from an
external USB Host on Module USB0. The
Module USB0 operates in Client Mode when
the Force Recovery function is invoked.
Pulled high on the Module. For SOCs that
do not implement a USB based Force
Recovery function, then a low on the Module
FORCE_RECOV# pin
may
invoke the SOC
native Force Recovery mode – such as over
a Serial Port. Pulled up on Module. Driven
by OD part on Carrier.)
P155
VDD_IN (Module power input voltage -
3.0V min to 5.25V max)
S156
BATLOW# (Battery low indication to
Module. Carrier to float the line in inactive
state. Pulled up on Module. Driven by OD
part on Carrier.)
Table 4-1: SMARC P-S Connector (J1) Signal Descriptions (Continued)
Содержание LEC-iMX6
Страница 4: ...iv Preface ...
Страница 36: ...30 ...