10
Figure 2-3: Bottom View of “MC” Enclosure with Mounting Holes
Optional mounting points for
surface/wall mounting or heat
sink (HPERC-KBL-MC only)
• Mounting holes “A” and “B” are shown below in Figure 2-3. Note
the recommended torque values and maximum depth of hole
“B”.
6.100 ±0.008
154.94 ±0.20
2.287 ±0.008
58.1 ±0.2
2.000 ±0.008
50.8 ±0.2
2.000 ±0.008
50.8 ±0.2
1.398 ±0.008
35.5 ±0.2
3.500 ±0.008
88.9 ±0.2
5.138 ±0.008
130.5 ±0.2
5.843 ±0.008
148.4 ±0.2
1.398 ±0.008
35.5 ±0.2
7.646 ±0.008 194.2 ±0.2
1.723 ±0.008 43.78 ±0.20
4.022 ±0.008 102.15 ±0.20
2.854 ±0.008
72.5 ±0.2
6.173 ±0.008 156.8 ±0.2
2.126 ±0.008
54 ±0.20
574.80 ±7.87
14.6 ±0.2
2000.00 ±7.87
50.8 ±0.2
A
A
A
A
B
B
B
B
B
B
B
A
A
Mounting Hole “A” Size: M4 threaded
Recommended Torque: 30 Kgf-cm (2.85 N-m)
Mounting Hole “B” Size: M4 threaded, max. depth 7mm