Страница 1: ...Leading EDGE COMPUTING DLAP 4000 Series 8th 9th Generation Intel Core i7 i5 i3 Processor Embedded Computer User s Manual Manual Rev 1 0 Revision Date Dec 28 2020 Part No 50 1Z344 1000...

Страница 2: ...ii Leading EDGE COMPUTING Revision History Revision Release Date Description of Change s 1 0 2020 12 28 Initial release...

Страница 3: ...of the use or inability to use the product or documentation even if advised of the possibility of such damages Environmental Responsibility ADLINK is committed to fulfill its social responsi bility t...

Страница 4: ...eir respective companies Conventions Take note of the following conventions used throughout this manual to make sure that users perform certain tasks and instructions properly NOTE NOTE Additional inf...

Страница 5: ...ock Diagram 5 2 2 Display Options 6 2 3 Mechanical Dimensions 7 3 System Layout 13 3 1 Front Panel 13 3 2 Internal I O Connectors 22 4 Getting Started 27 4 1 Attach AC Power Cord 27 4 2 Mounting the D...

Страница 6: ...vi Table of Contents Leading EDGE COMPUTING A 5 Chipset 61 A 6 Security 70 A 7 Boot 72 A 8 Save Exit 73 Important Safety Instructions 75 Consignes de S curit Importante 77 Getting Service 81...

Страница 7: ...nector Pin Definition 15 Table 3 3 DisplayPort Pin Definition 16 Table 3 4 HDMI Pin Definition 17 Table 3 5 DVI D Connector Pin Definition 18 Table 3 6 Ethernet Port Pin Definition 19 Table 3 7 Active...

Страница 8: ...viii List of Tables Leading EDGE COMPUTING This page intentionally left blank...

Страница 9: ...nition 15 Figure 3 4 DisplayPort Connector Pin Definition 16 Figure 3 5 HDMI Connector Pin Definition 17 Figure 3 6 DVI D Connector Pin Definition 18 Figure 3 7 Ethernet Port and LEDs 19 Figure 3 8 CO...

Страница 10: ...x List of Figures Leading EDGE COMPUTING This page intentionally left blank...

Страница 11: ...ic cards The DLAP 4000 series supports DDR4 memory for more powerful computing and the Intel HD Graphics 630 speeds graphics performance 1 2 Features X 8th 9th Gen Intel Core i7 i5 i3 FCLGA1151 proces...

Страница 12: ...ents are damaged inform your dealer immediately Retain the shipping carton and packing mate rials for inspection Obtain authorization from your dealer before returning any product to ADLINK Ensure tha...

Страница 13: ...T X Intel Core i7 8700 3 2GHz 12M Cache 65W TDP LGA1151 DDR4 2666MHz support 6C 12T X Intel Core i5 8500 3 0GHz 9M Cache 65W TDP LGA1151 DDR4 2666MHz support 6C 6T X Intel Core i3 8100 3 6GHz 6M Cache...

Страница 14: ...x16 slot Audio Mic in Line out Line in TPM 2 0 Optional Storage 2 5 SATA 2x 2 5 SATA 6Gb s internal drive bays Mechanical Dimensions 220 x 300 x 150 mm W x D x H Power Supply AC Input 100V to 240V AC...

Страница 15: ...32 Header x4 CPU Fan x1 Sys Fan x1 PCIe x16 slot Ver cal SODIMM DDR4 non ECC Channel B PCIe x16 CH5711 Passive Level Shi er HDMI Conn 1 4b ASM1442K Level Shi er TMDS LVDS HDA HDA Rear I O Conn x1 Line...

Страница 16: ...om its 8th 9th Generation Intel processors the DLAP 4000 controller can support or two independent displays with configurations as follows Table 2 2 Maximum Display Resolutions Port Resolution Display...

Страница 17: ...Specifications 7 DLAP 4000 2 3 Mechanical Dimensions All dimensions in millimeters mm Figure 2 2 DLAP 4000 Top View 220 301 12...

Страница 18: ...8 Specifications Leading EDGE COMPUTING Figure 2 3 DLAP 4000 Right Side View Figure 2 4 DLAP 4000 Left Side View...

Страница 19: ...Specifications 9 DLAP 4000 Figure 2 5 DLAP 4000 Bottom View...

Страница 20: ...10 Specifications Leading EDGE COMPUTING Figure 2 6 DLAP 4000 Rear View...

Страница 21: ...Specifications 11 DLAP 4000 Figure 2 7 DLAP 4000 Front View 150 4...

Страница 22: ...12 Specifications Leading EDGE COMPUTING This page intentionally left blank...

Страница 23: ...System Layout 13 DLAP 4000 3 System Layout 3 1 Front Panel The DLAP 4000 Series provides the following front panel access features Figure 3 1 Front Panel I O A B F L M O N C D E G I J K P H...

Страница 24: ...ear Panel I O Legend A AC Power Input J Mic In B COM Port RS 232 x4 K COM Port RS 232 422 485 C USB 2 0 Type A x2 L DVI D D Reset M DisplayPort E Power N HDMI F Extended Power Connector O Gigabit Ethe...

Страница 25: ...age Indicator The Storage Indicator indicates the HDD SSD operating state When the storage is active the LED indicator flashes red 3 1 3 Reset Button The reset button executes a hard reset for the DLA...

Страница 26: ...Figure 3 4 DisplayPort Connector Pin Definition Table 3 3 DisplayPort Pin Definition Pin Signal Pin Signal 1 DP1_CON_DP0 2 GND 3 DP1_CON_DN0 4 DP1_CON_DP1 5 GND 6 DP1_CON_DN1 7 DP1_CON_DP2 8 GND 9 DP1...

Страница 27: ...igure 3 5 HDMI Connector Pin Definition Table 3 4 HDMI Pin Definition Pin Signal Pin Signal 1 HDMI1_CON_DP2 2 GND 3 HDMI1_CON_DN2 4 HDMI1_CON_DP1 5 GND 6 HDMI1_CON_DN1 7 HDMI1_CON_DP0 8 GND 9 HDMI1_CO...

Страница 28: ...ices including USB flash drive USB external hard drive USB floppy USB CD ROM and others The boot priority and boot device can be configured in BIOS 3 1 9 USB 3 1 Ports The DLAP 4000 provides four USB...

Страница 29: ...EDs Table 3 6 Ethernet Port Pin Definition Table 3 7 Active Link LED Indicators Pin 10BASE T 100BASE TX 1000BASE T 1 TX LAN_MDI0 2 TX LAN_MDI0 3 RX LAN_MDI1 4 LAN_MDI2 5 LAN_MDI2 6 RX LAN_MDI1 7 LAN_M...

Страница 30: ...upport RS 232 422 485 modes by BIOS setting while COM2 to COM5 support only RS 232 Figure 3 8 COM Port Pin Definition Table 3 8 D Sub 9 pin Signal Function of COM Ports Pin Signal Name RS 232 RS 422 R...

Страница 31: ...pin con nectors Each GPIO can be defined as Input or Output by BIOS settings Figure 3 9 8 bit GPIO Connector Pin Definition Table 3 9 8 bit GPIO Pin Definition Pin Signal Pin Signal 1 GPIO0 2 GPIO4 3...

Страница 32: ...22 System Layout Leading EDGE COMPUTING 3 2 Internal I O Connectors 3 2 1 Mainboard Connector Locations Figure 3 10 Mainboard Front Connectors A B F L M O N C D E G I J K P H S T Q R...

Страница 33: ...System Layout 23 DLAP 4000 Figure 3 11 Mainboard Rear Connectors U...

Страница 34: ...transfers up to 6 0Gb s 600MB s 3 2 4 M 2 Connector The M 2 connector supports an M 2 2280 SATA SSD A ATX Power Connector L Clear CMOS CLCMOS1 B Mini PCIe M 2x DDR4 SODIMM C Debug Header N LVDS D Case...

Страница 35: ...m booting the jumper can clear the BIOS content stored in CMOS and restore default settings To clear CMOS short pin 2 to pin 3 for a minimum of 3 seconds and then remove the jumper to return to normal...

Страница 36: ...26 System Layout Leading EDGE COMPUTING This page intentionally left blank...

Страница 37: ...t it to an AC power source WARNING Before providing power ensure the voltage and polarity provided are compatible with the AC input Improper input voltage and or polarity can be responsible for system...

Страница 38: ...ated by the red circles below and use the 4 M4 6mm screws included in the screw pack to attach the 2 included wall mount brackets to the chassis Retirez les 4 repose pieds comme indiqu par les cercles...

Страница 39: ...Getting Started 29 DLAP 4000 wall mount brackets...

Страница 40: ...6 mounting holes circled in red according to the spacing dimensions of the holes in the bracket as shown in Figure 4 1 DLAP 4000 Wall mount Brackets Montez l appareil sur un mur l aide des 4 ouverture...

Страница 41: ...Getting Started 31 DLAP 4000 Figure 4 1 DLAP 4000 Wall mount Brackets 325 345 20 40 110 160 200 220 10 1 0 5 20 10 7 20 5 20...

Страница 42: ...32 Getting Started Leading EDGE COMPUTING 4 3 Installing 2 5 3 5 Storage 1 Remove the 6 screws indicated and remove the 2 top panels...

Страница 43: ...Getting Started 33 DLAP 4000 2 Remove the 4 screws indicated and remove the storage bracket from the chassis Storage bracket...

Страница 44: ...3 Use M3 4mm screws included in the Screw Pack to attach a 2 5 HDD SSD and 6 32 6 35mm screws to attach a 3 5 HDD Figure 4 2 Holes for 1st storage 2 5 HDD SSD Figure 4 3 Holes for 2nd storage 2 5 HDD...

Страница 45: ...Getting Started 35 DLAP 4000 Figure 4 4 Storage bracket with 2x 2 5 HDD SSD Figure 4 5 Storage bracket with 2 5 3 5 Drives 1st 2 5 HDD SSD 2nd 2 5 HDD SSD 2 5 HDD SSD 3 5 HDD...

Страница 46: ...36 Getting Started Leading EDGE COMPUTING 4 Use the 4 screws indicated to attach the storage backet to the chassis...

Страница 47: ...Getting Started 37 DLAP 4000 4 4 Installing M 2 Storage 1 Remove the screw and cover plate to access the M 2 storage area M2 Cover Plate...

Страница 48: ...38 Getting Started Leading EDGE COMPUTING 2 Use the M3 4mm screw included in the Screw Pack to install an M 2 SSD M3 4mm Screw M 2 SSD...

Страница 49: ...10 drivers for your system from the prod uct page at https www adlinktech com Products Industrial_PCs_Fanless_Embedded_PCs IPCSystems DLAP 4000_Series and install The following drivers must be instal...

Страница 50: ...40 Getting Started Leading EDGE COMPUTING This page intentionally left blank...

Страница 51: ...L keys User can change BIOS settings during setup utility runs A reset of system is required in order to make new settings take effect In BIOS setup utility there are several hot keys are designed for...

Страница 52: ...VT100 terminal via serial console Followings are the menu conventions X Using color The mandatory BIOS setup fields are in black The BIOS setup fields currently not used are in grey The display only...

Страница 53: ...old and the function of each setting is described in the right hand column of the respective table Main Advanced BIOS Information Memory Information Power Type System Date System Time CPU Configuratio...

Страница 54: ...on 2 Boot Option 3 Boot Option 4 Boot Option 5 Boot Option 6 Boot Option 7 Save Changes and Exit Discard Changes and Exit Save Changes and Reset Discard Changes and Reset Save Changes Discard Changes...

Страница 55: ...tion BIOS Information BIOS Vendor American Megatrends Core Version 5 13 0 45 x64 Compliancy UEFI 2 7 PI 1 6 Project Version AmITX CF I xxxx_xxxxx Build Date and Time Info only Access Level Administrat...

Страница 56: ...HW Monitor Monitor hardware status S5 RTC Wake Settings Enable system to wake from S5 using RTC alarm Serial Port Console Redirection Serial Port Console Redirection Intel TXT Information Display Int...

Страница 57: ...h change to new random owner epoch and manually entered by user After generating new epoch via Change to New Random Owner EPOCHs the selection reverts back to No Change in Owner Epochs this is to ensu...

Страница 58: ...ntel Speed Step or Intel Speed Shift to be available and enabled C states Disabled Enabled Enable Disable CPU Power Management Allows CPU to go to C States when it s not 100 utilized Enhanced C state...

Страница 59: ...r setting from UnLock to Lock after power on system Feature Options Description ACPI Settings Enable Hibernation Disabled Enabled Enable s or Disables System ability to Hibernate OS S4 Sleep State Thi...

Страница 60: ...ameters of Serial Port 5 WatchDog Count Mode Second Minute WatchDog Count Mode Selection WatchDog TimeOut Value 0 Fill WatchDog Timeout Value 0 means disabled Chassis Opened Warning Disabled Enabled S...

Страница 61: ...8h IRQ 3 4 5 6 7 9 10 11 12 IO 2E8h IRQ 3 4 5 6 7 9 10 11 12 Select optimal settings for Super IO Device COM Mode Select RS232 RS485 Half Duplex RS422 Full Duplex Configure the COM Port Mode Feature O...

Страница 62: ...9 10 11 12 IO 2E8h IRQ 3 4 5 6 7 9 10 11 12 IO 3E0h IRQ 3 4 5 6 7 9 10 11 12 IO 2E0h IRQ 3 4 5 6 7 9 10 11 12 Select optimal settings for Super IO Device Feature Options Description Serial Port 4 Con...

Страница 63: ...3E8h IRQ 3 4 5 6 7 9 10 11 12 IO 2E8h IRQ 3 4 5 6 7 9 10 11 12 IO 3E0h IRQ 3 4 5 6 7 9 10 11 12 IO 2E0h IRQ 3 4 5 6 7 9 10 11 12 Select optimal settings for Super IO Device Feature Options Description...

Страница 64: ...the SYS Smart Fan IV PWM 2 Value FAN Temperature 3 55 Input the SYS Smart Fan IV Temperature 3 FAN PWM 3 190 Input the SYS Smart Fan IV PWM 3 Value FAN Temperature 4 62 Input the SYS Smart Fan IV Temp...

Страница 65: ...Critical Temperature 90 Input the CPU Smart IV Critical Temperature FAN Critical Temperature Tolerance 1 Input Tolerance of Critical Temperature Range 0 7 Feature Options Description Smart Fan Mode Co...

Страница 66: ...Options Description COM1 Console Redirection Settings Terminal Type VT100 VT100 VT UTF8 ANSI Emulation ANSI Extended ASCII char set VT100 ASCII char set VT100 Extends VT100 to support color function...

Страница 67: ...ent This is to capture Terminal data Resolution 100x31 Disabled Enabled Enables or disables extended terminal resolution Putty KeyPad VT100 LINUX XTERMR6 SCO ESCN VT400 Select FunctionKey and KeyPad o...

Страница 68: ...es are connected DISABLE option will keep SUB devices available only for EFI applications XHCI Hand Off Disabled Enabled This is a workaround for OSes without XHCI hand off support The XHCI ownership...

Страница 69: ...Info only Option ROM execution Network Do not launch UEFI Legacy Controls the execution of UEFI and Legacy PXE OpROM Storage Do not launch UEFI Legacy Controls the execution of UEFI and Legacy Storage...

Страница 70: ...ort If disabled IPv4 PXE boot support will not be available Ipv6 PXE Support Disabled Enabled Enable Disable IPv6 PXE boot support If disabled IPv4 PXE boot support will not be available PXE boot wait...

Страница 71: ...Agent SA Parameters PCH IO Configuration PCH Parameters Feature Options Description System Agent SA Configuration SA PCIe Code Version Info only VT d Info only Memory Configuration Memory Configuratio...

Страница 72: ...sion Info only Memory Frequency Info only Memory Timings tCL tRCD tRP tRAS Info only DIMM_A1 Info only DIMM_B1 Info only Max TOLUD Dynamic 1GB 1 25GB 1 5GB 1 75GB 2GB 2 25GB 2 5GB 2 75GB 3GB 3 25GB 3G...

Страница 73: ...o Disabled Enabled Keep IGFX enabled based on the setup options PSMI Support Disabled Enabled PSMI Enable Disable DVMT Pre Allocated 0M 32M 64M 4M 8M 12M 16M 20M 24M 28M 32M F7 36M 40M 44M 48M 52M 56M...

Страница 74: ...z 18bits Single 1024x768 60Hz 18bits Single 1280x1024 60Hz 24bits Dual 1366x768 60Hz 18bits Single 1440x900 60Hz 24bits Dual 1680x1050 60Hz 24bits Dual 1920x1080 60Hz 24bits Dual 1920x1200 60Hz 24bits...

Страница 75: ...Reserved Memory 10 Reserved Memory for this Root Bridge Reserved I O 4 Reserved I O 4K 8K 12K 16K 20K Range for this Root Bridge Detect Non Compliance Device Disable Enable Detect Non Compliance PCI...

Страница 76: ...led Configure the digital GPIO pins GPIO 1 Control Input Output High Output Low Configure Digital I O Pin GPIO 2 Control Input Output High Output Low Configure Digital I O Pin GPIO 3 Control Input Out...

Страница 77: ...initial delay mini second PCI Express Root Port 5 Mini PCIe PCI Express Root Port 5 Mini PCIe Disabled Enabled Control the PCI Express Root Port ASPM 5 Disabled L0s L1 L0sL1 Auto Set the ASPM Level F...

Страница 78: ...t 2 Info only Software Preserve Port 2 Disabled Enabled Enable or Disable SATA Port Serial ATA Port 5 Info only Software Preserve Port 5 Disabled Enabled Enable or Disable SATA Port Feature Options De...

Страница 79: ...HD Audio Configuration Feature Options Description HD Audio Configuration HD Audio Disabled Enabled Control Detection of the HD Audio device Disabled HAD will be unconditionally disabled Enabled HAD...

Страница 80: ...requires a platform reset Secure Boot Mode Standard Custom In Custom mode Secure Boot Policy variables can be configured by a physically present user without full authentication Restore Factory Keys Y...

Страница 81: ...UEFI CA from DB Yes No Device Guard ready system must not list Microsoft UEFI CA Certificate in Authorized Signature database db Restore DB defaults Yes No Restore DB variable to factory defaults Sec...

Страница 82: ...e Resolution Disabled Enabled Enable or disable Support Native Resolution Driver Option Priorities Boot Mode LEGACY UEFI Automatically set CSM s item so LEGACY or UEFI FIXED BOOT ORDER Priorities Boot...

Страница 83: ...xit Yes No Exit system setup without saving any changes Save Changes and Reset Yes No Reset the system after saving the changes Default Options Restore Defaults Yes No Restore Load Default values for...

Страница 84: ...74 BIOS Setup Leading EDGE COMPUTING This page intentionally left blank...

Страница 85: ...ith Article 645 of the National Electrical Code and NFPA 75 X To avoid electrical shock and or damage to device Z Keep device away from water or liquid sources Z Keep device away from high heat or hum...

Страница 86: ...nnect the power supply cord before loosening the thumbscrews and always fasten the thumbscrews with a screwdriver before starting the system up X It is recommended that the device be installed only in...

Страница 87: ...s salles de technologie de l information conformes l article 645 du National Electrical Code et la NFPA 75 X Pour viter les chocs lectriques et ou d endommager l appareil Z Tenez l appareil l cart de...

Страница 88: ...ppareil ne fonctionne pas ou ne fonctionne pas selon le manuel de l utilisateur X L appareil est tomb et ou a t endommag et ou pr sente des signes vidents de dommage X D branchez le cordon d alimentat...

Страница 89: ...s de S curit Importante 79 DLAP 4000 RISQUE DE BR LURES Partie chaude Ne touchez pas cette surface cela pourrait entra ner des blessures Pour viter tout danger laissez la surface refroidir avant de la...

Страница 90: ...80 Consignes de S curit Importante Leading EDGE COMPUTING This page intentionally left blank...

Страница 91: ...408 360 0200 Toll Free 1 800 966 5200 USA only Fax 1 408 360 0222 Email info adlinktech com ADLINK Technology China Co Ltd 300 Fang Chun Rd Zhangjiang Hi Tech Park Pudong New Area Shanghai 201203 Chin...