Type 7 Starter Kit Plus 

 
Safety Instructions 

21 

Safety Instructions 

Read and follow all instructions marked on the product and in the documentation before you operate your system. 
Retain all safety and operating instructions for future use. 

 

Please read these safety instructions carefully. 

 

Please keep this User‘s Manual for later reference. 

 

The equipment should be operated only from the type of power source indicated on the rating label.  Make 
sure the voltage of the power source when connect the equipment to the power outlet. 

 

If your equipment has a voltage selector switch, make sure that the switch is in the proper position for your 
area. The voltage selector switch is set at the factory to the correct voltage. 

 

For pluggable equipment, that the socket-outlet shall be installed near the equipment and shall be easily 
accessible. 

 

Place the power cord such a way that people can not step on it.  Do not place anything over the power cord. 

 

If the equipment is not use for long time, disconnect the equipment from mains to avoid being damaged by 
transient overvoltage. 

 

All cautions and warnings on the equipment should be noted. 

 

Please keep this equipment from humidity. 

 

Do not use this equipment near water or a heat source. 

 

Lay this equipment on a reliable surface when install.  A drop or fall could cause injury. 

 

Never pour any liquid into opening; this could cause fire or electrical shock. 

 

Openings in the case are provided for ventilation. Do not block or cover these openings. Make sure you 
provide adequate space around the system for ventilation when you set up your work area. Never insert 
objects of any kind into the ventilation openings. 

 

To avoid electrical shock, always unplug all power cables and modem cables from the wall outlets before 
removing covers. 

 

Lithium Battery provided (real time clock battery) 

CAUTION – Risk of explosion if battery is replaced with one of an incorrect type. Dispose of used 
batteries according to the instructions

 

 

If one of the following situations arises, get the equipment checked by a service personnel: 

ƒ

 

The power cord or plug is damaged. 

ƒ

 

Liquid has penetrated into the equipment. 

ƒ

 

The equipment has been exposed to moisture. 

ƒ

 

The equipment has not work well or you can not get it work according to user‘s manual. 

ƒ

 

The equipment has dropped and damaged. 

ƒ

 

If the equipment has obvious sign of breakage. 

 

Содержание COM Express Type 7 Starter Kit Plus

Страница 1: ...Leading EDGE COMPUTING COM Express Type 7 Starter Kit Plus Quick Start Guide Manual Rev 1 0 Revision Date September 21 2017 Part Number 50 1J092 1000...

Страница 2: ...damages Environmental Responsibility ADLINK is committed to fulfill its social responsibility to global environmental preservation through compliance with the European Union s Restriction of Hazardou...

Страница 3: ...2 Board Installation 6 2 3 Power and I O Connectors 8 2 4 Powering Up the Express BASE7 System 9 3 10GbE Adapter Cards 11 3 1 10GbE SFP Card 11 3 2 10GbE BASE T Card 12 3 3 10GbE Adapter Card Installa...

Страница 4: ...iv Preface This page intentionally left blank...

Страница 5: ...Drivers BSP carrier board design files including schematics mechanical drawings and BOM certificates test reports COM Express module user s manual and thermal solution drawing are included to assist c...

Страница 6: ...DB40 40 pin flat cable External SPI cable used for BIOS update DB40 to BMC cable used for BMC FW update 4 31 32220 0000 Power Supply Unit 5 29 02480 0040 USB Flash Drive 2pcs One containing documents...

Страница 7: ...79010 0010 10GbE SFP adapter card Converts 2x 10GBASE KR to 2x 10GbE optical fiber SFP signals requires selection of a Type 7 module supporting Optical Fiber mode 5 91 79009 0010 10GbE BASE T adapter...

Страница 8: ...4 Introduction This page intentionally left blank...

Страница 9: ...ng Check that the EPE foam layers contain the items shown below 10GbE adapter card Express BASE7 Heatsink USB stick Memory USB stick Type 7 module Layer 1 Layer 2 Layer 3 EPE protection on top Remove...

Страница 10: ...y into the COM Express Type 7 module s SO DIMM socket Step 2 Removed all protective membranes from the thermal pads Step 3 Assemble the thermal solution onto the COM Express Type 7 module Step 4 Use t...

Страница 11: ...d thermal solution assembly onto the connectors on the carrier board as shown Step 6 Use the M2 5 L 16mm screws provided to secure the COM Express Type 7 module to the carrier board from the solder si...

Страница 12: ...upply into CN5 DO NOT plug the ATX 12V 4 pin connector into the ATX 24 pin power connector Plug the AC power cord into the power supply Connect the Keyboard Mouse and External GPU Card Required Items...

Страница 13: ...em Powering up the Express BASE7 system Required Items The POST LEDs on the Express BASE7 will display the bootup status A6 indicates a successful boot If no operating system is installed on the syste...

Страница 14: ...10 Getting Started This page intentionally left blank...

Страница 15: ...ropriate Type 7 COM Express module and paired 10GbE Adapter Card to achieve your desired functionality 3 1 10GbE SFP Card The 10GbE SFP Card is a COM Express Type 7 10GbE optical fiber network adapter...

Страница 16: ...10GBASE KR related sideband signals to 10GBASE T signals through 10GbE copper PHY Please download 10GbE BASE T Card User s Manual from ADLINK website for more detailed information www adlinktech com...

Страница 17: ...use 10GbE Optical Fiber card installed on the Express BASE7 carrier board with a Type 7 COM Express module Note The PCIe x16 slot indicated below PCIEKR has a proprietary pinout dedicated for 10GbE a...

Страница 18: ...14 10GbE Adapter Cards This page intentionally left blank...

Страница 19: ...ter Card The PCIe x16 to two PCIe x8 Adapter Card allows the use of two PCIe x8 add on cards from a single PCIe x16 slot Insert the adapter card into the PCIe x16 slot of the Express BASE7 carrier boa...

Страница 20: ...16 PCIe x16 to two PCIe x8 Adapter Card This page intentionally left blank...

Страница 21: ...OS update Interface to BMC for Board Management Controller BMC update Buttons for Power and Reset Status LEDs for Power Button Reset Button CB_PWPOK CB_RESET SLP_S3 SLP_S4 SLP_S5 The DB40 Debug Card c...

Страница 22: ...e buttons and switches on the DB40 debug card Power Button toggles the PWRBTN signal of the COM Express module Reset Button toggles the SYS_RESET signal of the COM Express module Mode Switch this 4 po...

Страница 23: ...lights on released SUS_S4 signal from COM Express module SUS_S5 LED lights on released SUS_S5 signal from COM Express module BMC_STATUS LED shows the status of the BMC on the COM Express module PWRBTN...

Страница 24: ...20 Debug Card This page intentionally left blank...

Страница 25: ...ge All cautions and warnings on the equipment should be noted Please keep this equipment from humidity Do not use this equipment near water or a heat source Lay this equipment on a reliable surface wh...

Страница 26: ...200 Toll Free 1 800 966 5200 USA only Fax 1 408 360 0222 Email info adlinktech com ADLINK Technology China Co Ltd Address 300 Fang Chun Rd Zhangjiang Hi Tech Park Pudong New Area Shanghai 201203 China...

Отзывы: