8
E
-95MR Hand Control Operation Guide 99300791-
c
E-95MR PROGRAMMING
1 hand control - 2 beds
The three step procedure below is required to program 1 hand control to operate 2
beds. Before beginning, make certain the beds are plugged into a working grounded
electrical outlet.
If programming fails, initiate the programming procedure a second
time.
STEP 2
On the hand control, simultaneously
press and hold the
flat
and the
head
massage on/off
buttons
(
FIGURE 3
).
The
transmission indicator light will
flash
slowly
and then
flash rapidly
to indicate
programming mode.
Continue to hold
for 5 seconds and then release the
buttons.
STEP 1
The bed will be equipped with either a
power down box
or
J box
receiver unit
(
FIGURE 2
). Locate the receiver unit for
the bed and press the
learn button
for 1
second and release.
Note: If you
experience difficulty locating or reaching
the learn button on a J box equipped
adjustable bed, refer to
J Box
Programming
on page 5.
J BOX
FIGURE 2: Power down box and J box receiver units.
LEARN
BUTTON
LEARN
BUTTON
POWER
DOWN BOX
POWER DOWN
BOX RECEIVER
UNIT IS NOT
MOUNTED TO
BED FRAME.
J BOX RECEIVER
UNIT IS MOUNTED
TO THE BOTTOM
SIDE OF THE
BED FRAME.
STEP 3
Repeat Step 1 and Step 2 for bed 2.
One hand control is now programmed to
operate two beds.
BED 1
BED 2
FLAT BUTTON
TRANSMISSION
INDICATOR LIGHT
FIGURE 3
HEAD MASSAGE
ON/OFF BUTTON