ADJ Products, LLC - www.adj.com - WiFly QA5 IP User Manual Page 12
With this feature you can connect the fixtures to one another
using the IEC input and output sockets. The quantity that can be
connected is 15 fixtures maximum. After the maximum fixtures
has been reached you will need to use a new power outlet. They
must be the same fixtures. DO NOT mix fixtures.
WiFly QA5 IP Power Cord Daisy Chain
WiFly QA5 IP Master-Slave Configuration
Master-Slave Configuration:
This function will allows you to link units together to run in a Master-Slave
mode. In Master-Slave operation one unit will act as the controlling unit
and the others will react to the controlling units built-in programs. Any
unit can act as a Master or as a Slave however, only one unit can be pro-
grammed to act as the “Master.”
Master-Slave Connections and Settings:
1. Daisy chain your units via the XLR connector on the rear of the unit.
Use standard XLR data cables to link your units together. Remember
that the Male XLR connector is the input and the Female XLR con-
nector is the ouput. The first unit in the chain (master) will use the
female XLR connector only. The last unit in the chain will use the
male XLR connector only.
2. Set the “Master” unit to your desired mode of operation.
3. On the “Slave” units press the MODE button
until “SLAu” is dis-
played. The unit is now set as the “Slave” unit. Each slave unit
must be set to the same setting.
4. Connect the first “Slave” unit to the “Master”, and the “Slave” unit
should now start follow the “Master”.
ADJ Products, LLC - www.adj.com - WiFly QA5 IP User Manual Page 15
Channel Value
Function
1 RED
0 - 255 0% - 100%
2 GREEN
0 - 255 0% - 100%
3 BLUE
0 - 255 0% - 100%
4 AMBER
0 - 255 0% - 100%
5 MASTER DIMMER
0 - 255 0% - 100%
WiFly QA5 IP 5 Channel - DMX Values & Functions
WiFly QA5 IP 4 Channel - DMX Values & Functions
Channel Value
Function
1 RED
0 - 255 0% - 100%
2 GREEN
0 - 255 0% - 100%
3 BLUE
0 - 255 0% - 100%
4 AMBER
0 - 255 0% - 100%