ADJ Products, LLC
ww.adj.com
VIZI CMY 16RX User Instructions Page 33
Frost:
Frost home position adjustment.
1.
Press the
ENTER
button for at least 3 seconds, then press the
UP
or
DOWN
buttons so that “Frost” is displayed, press
ENTER
.
2.
Use the
UP
and
DOWN
buttons to make your adjustments, and then press
ENTER
to confirm. Press the
MENU
button for one second to exit.
Focus:
Focus home position adjustment.
1.
Press the
ENTER
button for at least 3 seconds, then press the
UP
or
DOWN
buttons so that “Focus” is displayed, press
ENTER
.
2.
Use the
UP
and
DOWN
buttons to make your adjustments, and then press
ENTER
to confirm. Press the
MENU
button for one second to exit.
Zoom:
Zoom home position adjustment.
1.
Press the
ENTER
button for at least 3 seconds, then press the
UP
or
DOWN
buttons so that “Zoom” is displayed, press
ENTER
.
2.
Use the
UP
and
DOWN
buttons to make your adjustments, and then press
ENTER
to confirm. Press the
MENU
button for one second to exit.
If any of these warnings appear and you are not certain on what form of action needs to
be taken, please contact ADJ customer support for more information.
Lamp Startup Fail:
Appears when there is no lamp or some wires are damaged.
Temperature Sense Error:
Appears when Temperature Check Board is damaged.
Lamp Too Hot Power Off:
Appears when temperature is detected higher than 110
℃
.
Check if unit is properly ventilated, or fans or Temperature Check Board may be
damaged.
Lamp Too Hot Low Power:
Appears when detected temperature is higher than 105
℃
.
The unit will run on a low power level.
Lamp On Over 700 Hour:
Appears when the lamp always has been on over 700 hours.
Please turn off the lamp.
Memory Initial Fail:
It appears when the memory IC is damaged.
CPU
‐
B Error, CPU
‐
C Error, and CPU
‐
D Error:
Message appears when board P.C or
some wires are damaged.
Random Error Messages:
“Pan Reset Error”, “Pan Encode Error”, “Tilt Reset Error”,
“Tilt Encode Error”, “Shutter Reset Fail”, “Dimmer Reset Fail”, “Color Reset Fail”, “Cyan
Reset Fail”, “Magenta Fail”, “Yellow Reset Fail”, “Gobo1 Reset Fail”, “R-Gobo1
Reset Fail”, “Gobo2 Reset Fail”, “Iris Reset Fail”, “Effect Reset Fail”,
“
R-Effect Reset
Fail”, “Frost Reset Fail”, “Flat Reset Fail”, “Focus Reset Fail” or “Zoom Reset Fail”.
These may appear when turning on or resetting the unit. If some parts such as the
PC Board are damaged. Please contact ADJ customer support.
VIZI CMY 16RX
System Menu
VIZI CMY 16RX
Error Information
Содержание VIZI CMY 16RX
Страница 1: ...VIZI CMY 16RX User Instructions...