S A F E T Y   G U I D E L I N E S

This fixture is a sophisticated piece of electronic equipment. To guarantee smooth operation, it is 

important to follow all instructions and guidelines in this manual. ADJ is not responsible for injury and/

or damages resulting from the misuse of this fixture due to the disregard of the information printed in 

this manual. Only qualified and/or certified personnel should perform installation of this fixture and only 

the original rigging parts (omega brackets) included with this fixture should be used for installation. Any 

modifications to the fixture and/or the included mounting hardware will void the original manufacturer’s 

warranty and increase the risk of damage and/or personal injury.

PROTECTION CLASS 1 - FIXTURE MUST BE PROPERLY GROUNDED.

THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT. DO NOT ATTEMPT 

ANY REPAIRS YOURSELF, AS DOING SO WILL VOID YOUR MANUFACTURER’S 

WARRANTY. DAMAGES RESULTING FROM MODIFICATIONS TO THIS FIXTURE 

AND/OR THE DISREGARD OF SAFETY INSTRUCTIONS AND GUIDELINES IN THIS 

MANUAL VOID THE MANUFACTURER’S WARRANTY AND ARE NOT SUBJECT TO 

ANY WARRANTY CLAIMS AND/OR REPAIRS.
DO NOT PLUG FIXTURE INTO A DIMMER PACK!

NEVER OPEN THIS FIXTURE WHILE IN USE!

DISCONNECT FIXTURE FROM POWER BEFORE SERVICING!

NEVER TOUCH THE FIXTURE DURING OPERATION, AS IT MAY BE HOT!

KEEP FLAMMABLE MATERIALS AWAY FROM THE FIXTURE!

NEVER LOOK DIRECTLY INTO THE LIGHT SOURCE!

RETINA INJURY RISK - MAY INDUCE BLINDNESS!

SENSITIVE PERSONS MAY SUFFER AN EPILEPTIC SHOCK!

MAXIMUM EXTERNAL SURFACE TEMPERATURE: 185° F (85° C)

MAXIMUM AMBIENT TEMPERATURE: 104° F (40° C)

•  DO NOT TOUCH the fixture housing during operation.

•  Turn OFF the power and allow approximately 15 minutes for the fixture to cool down before 

serving.

•  DO NOT shake fixture, avoid brute force when installing and/or operating fixture.

•  DO NOT operate fixture if the power cord is frayed, crimped, damaged and/or if any of the power cord 

connectors are damaged and do not insert into the fixture securely with ease. NEVER force a power cord 

connector into the fixture. If the power cord or any of its connectors are damaged, replace it immediately 

with a new one of similar power rating.

•  NEVER force a power cord connector into the fixture. If the power cord or any of its connectors 

are damaged, replace it immediately with a new one of similar power rating.

•  DO NOT block any air ventilation slots. All fan and air inlets must remain clean and never 

blocked. Allow approx. 7.9” (20cm) between fixture and a wall for proper cooling.

•  When installing fixture in a suspended environment, always use mounting hardware that is at 

least M10 x 25 mm, and always install fixture with an appropriately rated safety cable.

•  Always disconnect fixture from main power source before performing any type of service and/or 

cleaning procedure.

•  Only handle the power cord by the plug end, and never pull out the plug by tugging the wire 

portion of the cord.

•  During the initial operation of this fixture, a light smoke or smell may emit from the interior of 

the fixture. This is a normal process and is caused by excess paint in the interior of the casing 

burning off from the heat associated with the lamp and will decrease gradually over time.

•  Consistent operational breaks will ensure fixture will function properly for many years.

•  In the event that the fixture needs to be returned for servicing, use only the original packaging 

and materials to transport the fixture.

Содержание VIZ007

Страница 1: ...VIZI BEAM 5RX User Guide...

Страница 2: ...t building and electrical damages injuries to any persons and direct or indirect economic loss associated with the use or reliance of any information contained within this document and or as a result...

Страница 3: ...ion Instructions 11 Lamp Replacement 13 Setup 18 System Menu 19 DMX Control 21 Offset Menu 26 Photometric Chart 24 DMX Channel Functions and Values 25 Specifications 30 CONTEN T S Please see Important...

Страница 4: ...card the outer shipping carton in the trash Please recycle whenever possible CUSTOMER SUPPORT Contact ADJ Service for any product related service and support needs Also visit forums adj com with quest...

Страница 5: ...ir labor by reason of defects in material or workmanship The sole responsibility of ADJ Products LLC under this warranty shall be limited to the repair of the product or replacement thereof including...

Страница 6: ...housing during operation Turn OFF the power and allow approximately 15 minutes for the fixture to cool down before serving DO NOT shake fixture avoid brute force when installing and or operating fixt...

Страница 7: ...iris shutters motors belts wiring discharge lamps and LEDs This issue is not specific only to ADJ lighting fixtures it is a common issue with lighting fixtures from all manufacturers Although there i...

Страница 8: ...n dealing with older lamps Extreme caution should be used when operating this or any fixture fitted with a gas discharge lamp Never open this unit while in use VERY IMPORTANT This notice pertains to y...

Страница 9: ...operation resulting in damage or injury as larger parts could fall Check for any deformations on the housing color lenses rigging hardware and rigging points ceiling suspension trussing Deformations...

Страница 10: ...10 OVERVIEW LCD Display Power Switch Fuse 250V 10A Power Cable In 3 Pin DMX In 3 Pin DMX Out POWER AND DMX SIGNAL INPUT LEDs...

Страница 11: ...e unauthorized personnel might reach the fixture by hand NEVER stand directly below the fixture s when rigging removing or servicing Overhead fixture installation must always be secured with a seconda...

Страница 12: ...ill allow the fixture to run at its best and help prolong the fixture life INSTALLAT I O N I NSTR U C TION S When installing the unit the trussing or area of installation must be able to hold 10 times...

Страница 13: ...before attempting to replace the lamp Please see page 7 for important information regarding the discharge lamp See the next pages for lamp replacement instructions Be sure to follow the proper handli...

Страница 14: ...PL ACEMENT 2 Ensure the moving head is horizontal as shown below and remove the lamp cooling fan at the rear of the head 1 Use a screwdriver to unlock and remove the moving head cover panel using a sc...

Страница 15: ...15 LAMP REPL ACEMENT 4 Connect the replacement lamp 3 Lift the lamp out of its socket as show and disconnect it...

Страница 16: ...6 Adjust the lamp using a slotted screwdriver until it s centered 7 Reinstall the fan then replace and secure the head covers DO NOT connect to power until covers are installed 5 Place the new lamp i...

Страница 17: ...in a DMX line at the beginning at the end or anywhere in the middle When a fixture is assigned a DMX address of 1 the DMX controller knows to send DATA assigned to address 1 to that unit no matter whe...

Страница 18: ...l decrease the possibilities of erratic behavior 3 Pin XLR to 5 Pin XLR Conversion Conductor 3 Pin XLR Female Out 5 Pin XLR Male In Ground Shield Pin 1 Pin 1 Data Compliment signal Pin 2 Pin 2 Data Tr...

Страница 19: ...press ENTER to confirm your setup then press and hold the MENU button for at least 3 seconds To exit without making any adjustments press the MENU button The display will lock after 30 seconds Press t...

Страница 20: ...the display backlight turn off after 10 seconds 1 Press the MENU button until LED is displayed press ENTER 2 The display will show either ON or OFF Press the UP or DOWN buttons to select ON to keep th...

Страница 21: ...Use this function to revert back to the default settings 1 Press the either the MENU button until deF is displayed press ENTER 2 The display will show the software version RSET Use this function to r...

Страница 22: ...desired operation of this fixture compared to others being used at the same time Because this can be an extremely detailed procedure careful consideration must be used before making any changes Please...

Страница 23: ...el 1 Press the ENTER button for at least 3 seconds then press the UP or DOWN buttons so that oGob is displayed and press ENTER 2 Use the UP and DOWN buttons to make your adjustments and then press ENT...

Страница 24: ...24 PHOTOM E T RIC C H ART...

Страница 25: ...9 10 Color 2 11 12 Color 2 Color 3 13 14 Color 3 15 16 Color 3 Color 4 17 18 Color 4 19 21 Color 4 Color 5 22 23 Color 5 24 25 Color 5 Color 6 26 27 Color 6 28 29 Color 6 Color 7 30 31 Color 7 32 33...

Страница 26: ...10 34 36 Gobo 11 37 39 Gobo 12 40 42 Gobo 13 43 45 Gobo 14 46 48 Gobo 15 49 51 Gobo 16 52 55 Gobo 17 56 59 Open Shaking 60 63 Gobo 1 Shaking 64 68 Gobo 2 Shaking 69 71 Gobo 3 Shaking 72 75 Gobo 4 Shak...

Страница 27: ...t 7 160 164 Prism Rotation Effect 8 165 168 Prism Rotation Effect 9 169 173 Prism Rotation Effect 10 174 177 Prism Rotation Effect 11 178 182 Prism Rotation Effect 12 183 187 Prism Rotation Effect 13...

Страница 28: ...r Strobing Slow Fast 168 203 Fast Close Slow Open 204 239 Fast Open Slow Close 240 247 Random Strobe 248 255 Open 12 12 0 255 Master Dimmer Intensity 0 100 13 13 Pan Tilt Macros 0 7 Off 8 15 Macro 1 1...

Страница 29: ...19 Special Functions 0 49 No Function 50 59 Pan Tilt Fast Mode 60 69 Pan Tilt Normal Mode 70 79 Blackout With Pan Tilt Move Enabled 80 89 Blackout With Pan Tilt Move Disabled 90 99 Blackout With Color...

Страница 30: ...Tilt Positioning Motorized focus Shutter Pulse effect random strobe slow to fast Mechanical Dimming 0 100 Strobe effect Frost Filter Stepper motors with micro stepping Omega Quicklock Brackets include...

Страница 31: ...31 DIMENSIO N D RAW ING S Dimensions not to scale...

Страница 32: ...erence to radio communications However there is no guarantee that interference will not occur in a particular installation If this device does cause harmful interference to radio or television recepti...

Страница 33: ......

Отзывы: