SET UP (continued) 

Data  Cable  (DMX  Cable)  Requirements  (For  DMX  and  Master/Slave  Operation): 

The  Stinger  II  can  be 

controlled  via  DMX-512  protocol.  The  Stinger  II  is  has  2  DMX  channel  modes,  a  2  channel  mode  and  9 
channel  mode.  The  DMX  address  is  set  electronically  using  the  controls  on  the  back 
panel  of  the  unit.  Your  unit  and  your  DMX  controller  require  a  approved  DMX-512  110 
Ohm  Data cable for  data  input  and  data  output (Figure  1). We recommend  Accu-Cable 
DMX cables. If you are making your own cables, be sure to use standard 110-120 Ohm 
shielded  cable  (This  cable  may  be  purchased  at  almost  all  professional  sound  and 
lighting stores). Your cables should be made with a male and female XLR connector on 
either  end  of  the  cable.  Also  remember  that  DMX  cable  must  be  daisy  chained  and 
cannot be split.

 

Notice: 

Be sure to follow figures two and three when making your own cables. Do not use the ground lug on 

the XLR connector. Do not con

nect the cable’s shield conductor to the ground lug or allow the shield conductor 

to  come  in 

contact with the XLR’s outer casing. Grounding the shield could cause a short circuit and erratic 

behaviour.  

 

 

 

 

XLR Pin Configuration 

 

Pin1 = Ground 

 

Pin2 = Data Compliment (negative) 

 

Pin3 = Data True (positive) 

Figure 3 

Special Note: Line Termination. 

When longer runs of cable are used, you may need to use a terminator on 

the  last  unit  to  avoid  erratic  behaviour.  A  terminator  is  a  110-120  ohm  1/4  watt  resistor  which  is  connected 
between pins 2 and 3 of a male XLR connector (DATA + and DATA -). This unit is inserted in the female XLR 
connector of the last unit in your daisy chain to terminate the line. Using a cable terminator (ADJ part number 
Z-DMX/T) will decrease the possibilities of erratic behaviour. 

 

Termination  reduces  signal  errors  and  avoids 
signal transmission problems and interference.  
It  is  always  advisable  to  connect  a  DMX 
terminal,  (Resistance120  Ohm  1/4  W)  between 
PIN  2  (DMX-)  and  PIN  3  (DMX  +)  of  the  last 
fixture. 

 
 
 
Figure 4 
 
 

 

5-Pin XLR DMX Connectors

Some manufactures use 5-pin XLR connectors for DATA transmission in place 

of 3-pin. 5-pin XLR fixtures may be implemented in a 3-pin XLR DMX line. When inserting standard 5-pin XLR 
connectors  in  to  a  3-pin  line  a  cable  adaptor  must  be  used,  these  adaptors  are  readily  available  at  most 
electric stores. The chart below details a proper cable conversion. 

3-Pin XLR to 5-Pin XLR Conversion

 

Conductor 

3-pin XLR Female (Out) 

5-pin XLR Male (In) 

Ground/Shield 

Pin 1 

Pin 1 

Data compliment (- signal) 

Pin 2 

Pin 2 

Data True (+ signal) 

Pin 3 

Pin 3 

Not used 

 

Pin 4 - Do Not Use 

Not used 

 

Pin 5 - Do Not Use 

Figure 2 

Figure 1 

Содержание stinger ii

Страница 1: ...User Instructions A D J Supply Europe B V Junostraat 2 6468 EW Kerkrade The Netherlands www americandj eu Rev 3 16...

Страница 2: ...ter granted Product names used in this document may be trademarks or registered trademarks of their respective companies and are hereby acknowledged All non ADJ Products LLC brands and product names a...

Страница 3: ...ETY 5 SET UP 6 INSTALLATION 8 LASER WARNING LABELS 8 SYSTEM MENU 9 OPERATION 11 MASTER SLAVE SET UP 12 POWER CORD DAISY CHAIN 12 EMERGENCY BLACKOUT 12 UC IR AIRSTREAM CONTROL 12 2 CHANNEL MODE 13 9 CH...

Страница 4: ...contact us directly You can contact us via our website www americandj eu or via email support americandj eu Warning To prevent or reduce the risk of electrical shock or fire do not expose this unit t...

Страница 5: ...plifiers that produce heat The fixture should be serviced by qualified service personnel when A The power supply cord or the plug has been damaged B Objects have fallen or liquid has been spilled into...

Страница 6: ...is open or if the optics appear damaged in any way Never open the laser housing The high laser power levels inside of the protective housing can start fires burn skin and will cause instant eye injury...

Страница 7: ...onfiguration Pin1 Ground Pin2 Data Compliment negative Pin3 Data True positive Figure 3 Special Note Line Termination When longer runs of cable are used you may need to use a terminator on the last un...

Страница 8: ...ly fixed to avoid vibration and slipping while operating Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times the unit s weight Al...

Страница 9: ...seconds press the MENU button for 3 seconds to unlock ADDR DMX Address Setting 1 Press the either the MENU UP or DOWN buttons until ADDR is displayed press ENTER 2 The current address will now be disp...

Страница 10: ...to each other SOUN Sound Active mode 1 Press the MENU button until SOUN is displayed press ENTER 2 The display will show either ON or OFF Press the UP or DOWN buttons to select ON to activate sound a...

Страница 11: ...ION Universal DMX Control This function allows you to use a universal DMX 512 controller to control the patterns rotation and strobing A DMX controller allows you to create unique programs tailored to...

Страница 12: ...lets you instantly blackout the unit Have the emergency key inserted into the keyhole at all times To activate the emergency blackout feature turn it to the Off position To reactivate the unit turn t...

Страница 13: ...248 255 SOUND ACTIVE 9 CHANNEL MODE Channel Value Function 1 SHOW MODE 0 9 NO FUNCTION 10 44 SHOW 1 45 79 SHOW 2 80 114 SHOW 3 115 149 SHOW 4 150 184 SHOW 5 185 219 SHOW 6 220 255 RANDOM SHOW 2 COLOR...

Страница 14: ...g residue smoke and dust cleaning the internal and external optical lenses and mirror should be carried out periodically to optimize light output Cleaning frequency depends on the environment in which...

Страница 15: ...x LEDs 8 x 3W UV LEDs 4 9mW Red Green Laser Diodes 70W 2A 10 Fixtures Max 12 L x 9 W x 9 75 H 304mm x 230 5mm x9 75mm 11 lbs 5 kgs RGBAWP None 2 DMX Modes 2 9 Channels Yes Any Safe Secure Position Aut...

Страница 16: ...each kind of electronics we have around us in our households or at work As manufacturers of products of the brands of AMERICAN AUDIO AMERICAN DJ ELATION Professional and ACCLAIM Lighting we are obliga...

Страница 17: ...to develop a common system of waste management Thereby we can ensure professional and environmentally friendly scraping and recycling program As manufactures we are part of the German system of EAR an...

Страница 18: ...A D J Supply Europe B V www americandj eu Stinger II Instruction Manual Page 18 NOTES...

Страница 19: ...A D J Supply Europe B V www americandj eu Stinger II Instruction Manual Page 19 NOTES continued...

Страница 20: ...A D J Supply Europe B V www americandj eu Stinger II Instruction Manual Page 20 A D J Supply Europe B V Junostraat 2 6468 EW Kerkrade The Netherlands www americandj eu...

Отзывы: