background image

8

S E T   U P

Unpacking:

Every Stage Setter 8 has been thoroughly tested and shipped in perfect operating order. Carefully 

check the shipping carton for damage that may have occurred during shipping. If the carton appears 

to have been damaged, carefully inspect your fixture for any damage. In the event that damage has 

been found, please contact our toll free customer support number for further instructions.

Power Supply:

Before plugging your unit in, be sure that the voltage of the power source matches the required volt-

age for your ADJ Stage Setter 8. The ADJ Stage Setter 8 is available in a 115v and 230v version. 

Please be aware that line voltage may vary from venue to venue.  

Data Cable (DMX Cable) Requirements:

Your controller and packs require a standard 3-pin XLR connector for DMX data input and DMX data 

output (Figure 1). If you are making your own cables, use standard two conductor shielded cable, 

which may be purchased at almost all professional sound and lighting stores. Your cables should be 

made with a male XLR connector at one end and a female XLR connector at the other. Also remem-

ber that DMX cable must be daisy chained and can not be “Y”ed or split.

Notice: Do not use the ground lug on the XLR connector.  Do not connect the cable’s shield conduc-

tor to the ground lug or allow the shield conductor to come in contact with the  XLR’s outer casing.  

Grounding the shield could cause a short circuit and erratic behavior. Refer to the figures below when 

making your own cables.

Special Note: Line Termination.

When longer run of cable are used, it may be necessary to use a terminator on the last unit in order 

to avoid erratic behavior. A terminator is a 90-120 ohm 1/4 watt resistor which is connected between 

pins 2 and 3 of a male XLR connector (DATA+ and DATA-). This unit is inserted in the female XLR 

connector of the last unit in your daisy chain to terminate the line. Using a cable terminator will de-

crease the possiblities of erratic behavior.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 IN

CONNECTOR

3 PIN

DMX512 OUT

CONTROLLER

CONNECTOR

3 PIN

1 Ground

1 Ground

XLR Male Socket

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Shield

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

Содержание STAGE SETTER 8

Страница 1: ...User Manual STAGE SETTER 8 Revised 08 16 2022...

Страница 2: ...eby disclaim any and all liabilities for property equipment building and electrical damages injuries to any persons and direct or indirect economic loss associated with the use or reliance of any info...

Страница 3: ...4 Limited Warranty USA Only 6 Safety Guidelines 7 Set Up 8 Front Panel Control and Functions 9 Rear Panel Control and Functions 12 General Operation 13 Basic Programming 15 MIDI Operation 17 LCD Value...

Страница 4: ...ay Friday 08 30 to 17 00 CET Voice 31 45 546 85 60 Fax 31 45 546 85 96 support adj eu ADJ PRODUCTS LLC USA 6122 S Eastern Ave Los Angeles CA 90040 323 582 2650 Fax 323 532 2941 www adj com info adj co...

Страница 5: ...2 x 8 8 x 8 and 1 x 16 12 chase options 4 built in and 8 user programmable 32 steps scenes per program MIDI compatible Fog machine output button Scene crossfader Tap SYNC button 8 Bump Buttons Back up...

Страница 6: ...es for warranty service and repair labor by reason of defects in material or workmanship The sole responsibility of ADJ Products LLC under this warranty shall be limited to the repair of the product o...

Страница 7: ...t of an internal short Disconnect from main power before making any type of connection Do not remove the top cover under for any reason There are no user serviceable parts inside Disconnect the unit s...

Страница 8: ...ble must be daisy chained and can not be Y ed or split Notice Do not use the ground lug on the XLR connector Do not connect the cable s shield conduc tor to the ground lug or allow the shield conducto...

Страница 9: ...9 F R O N T PA N E L C O N T R O L S A N D F U N C T I O N S 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17...

Страница 10: ...llows easy dipless crossfading between scenes when both crossfaders are moved together 7 LCD DISPLAY This multifunctional display will detail the unit s current operation The LCD will indicate an acti...

Страница 11: ...ity This function will override the Blackout 15 function A Full On LED 14 will glow when Full On 14 is active 15 BLACKOUT BUTTON This button is used to disable all channel outputs 1 16 Only the Full O...

Страница 12: ...I device 22 MIDI IN This jack receives an incoming MIDI signal from external MIDI controller or keyboard 23 FOG MACHINE CONNECTOR Use this connection to connect a compatible ADJ fog machine This elimi...

Страница 13: ...Master Scenes can only be used while in the 8x8 operating mode When in the 8x8 mode the Bump Buttons 10 and the Scene Y 11 sliders can be used to store a Master Scene which consists of channels 1 8 T...

Страница 14: ...de 3 Tap the Bump Button that corresponds to a Scene Y slider that will be used to store the scene The scene will now be stored as a Master Scene in the Scene Y slider and will be ready for immediate...

Страница 15: ...ple 1 Programming a 32 step chase into the Chase 5 Bank Button using the Scene X Sliders 2 2 Tap the Record Button 4 and the record LED will illuminate 3 Tap the Chase 5 Button 17 and the Chase 5 LED...

Страница 16: ...X 2 and Scene Y 11 sliders to the fully down position 6 Move Scene X slider 7 to the full intensity position 7 Tap the Record Button 4 once The LCD 7 will read 01 8 Move Scene X slider 8 to the full...

Страница 17: ...DI Receive channel should be displayed in the LCD 3 Tap Bump Button 8 to change the MIDI Receive channel Selectable values range from channels 1 16 4 Tape the Blackout Button to exit MIDI Setting mode...

Страница 18: ...isplayed in the LCD 3 Tap Bump Button 7 to toggle the display value between 255 DMX channel values and 100 dim mer percentage value 4 Tap the Blackout Button to exit the adjustment mode M E M O R Y D...

Страница 19: ...lt in programs Eight user programmable programs Fog machine output control Standard DMX 512 protocol MIDI compatible ADJ Products LLC 6122 S Eastern Ave Los Angeles CA 90040 USA Tel 323 582 2650 Fax 3...

Страница 20: ......

Отзывы: