ADJ MINI DEKKER Скачать руководство пользователя страница 3

ADJ Products, LLC  -  www.adj.com  - Mini Dekker Instruction Manual Page 4

ADJ Products, LLC  -  www.adj.com  - Mini Dekker Instruction Manual Page 5

  Mini Dekker                                  Safety Precautions

•   To reduce the risk of electrical shock or fire, do not expose this unit  

   rain or moisture

•   Do not spill water or other liquids  into or on to your unit.

•   Be sure that the local power outlet match that of the required volt- 

   age for your unit.

•   Do not attempt to operate this unit if the power cord has been   

   frayed or broken. Do not attempt to remove or break off the ground 

   prong from the electrical cord. This prong is used to reduce the risk  

   of electrical shock and fire in case of an internal short.

•   Disconnect from main power before making any type of connection.

•   Do not remove the cover under any conditions. There are no user  

   serviceable parts inside.

•   Never operate this unit when it’s cover is removed.

•   Never plug this unit in to a dimmer pack

•   Always be sure to mount this unit in an area that will allow proper  

   ventilation. Allow about 6” (15cm) between this device and a wall.

•   Do not attempt to operate this unit, if it becomes damaged.

•   This unit is intended for indoor use only, use of this product out`  

   doors voids all warranties.

•   During long periods of non-use, disconnect the unit’s main power.

•   Always mount this unit in safe and stable matter.

•   Power-supply cords should be routed so that they are not likely to  

   be walked on or pinched by items placed upon or against them,  

   paying particular attention to the point they exit from the unit. 

• Cleaning -The fixture should be cleaned only as recommended by  

  t he manufacturer. See page 11 for cleaning details.

•   Heat -The appliance should be situated away from heat sources  

   such as radiators, heat registers, stoves, or other appliances (inclu-

   d ing amplifiers) that produce heat.

•   The fixture should  be serviced by qualified service personnel    

   when:

    A. The power-supply cord or the plug has been damaged.

    B. Objects have fallen, or liquid has been spilled into the appliance.

    C. The appliance has been exposed to rain or water.

    D. The appliance does not appear to operate normally or exhibits a  

        marked change in performance.

Power Supply:

 The ADJ Mini Dekker contains a automatic voltage 

switch, which will auto sense the voltage when it is plugged into the 

power source. With this switch there is no need to worry about the cor-

rect power voltage, this unit can be plugged in anywhere.  

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol used as a form of communication between intelligent fixtures 

and controllers. A DMX controller sends DMX data instructions from 

the controller to the fixture. DMX data is sent as serial data that trav-

els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter-

minals located on all DMX fixtures (most controllers only have a DATA 

“OUT” terminal). 

DMX Linking: 

DMX is a language allowing all makes and models of 

different manufactures to be linked together and operate from a sin-

gle controller, as long as all fixtures and the controller are DMX com-

pliant. To ensure proper DMX data transmission, when using several 

DMX fixtures try to use the shortest cable path possible. The order 

in which fixtures are connected in a DMX line does not influence the 

DMX addressing. For example; a fixture assigned a DMX address of 1 

may be placed anywhere in a DMX line, at the beginning, at the end, 

or anywhere in the middle. When a fixture is assigned a DMX address 

of 1, the DMX controller knows to send DATA assigned to address 1 

to that unit, no matter where it is located in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX Operation):

 

The Mini Dekker is a 9 channel DMX unit. The DMX address is set elec-

tronically  using  the  controls  on  the  rear  panel  of  the  unit. Your  unit 

and your DMX controller require a approved DMX-512 110 Ohm Data 

cable for data input and data output. We recommend Accu-Cable DMX 

cables. If you are making your own cables, be sure to use standard 

110-120 Ohm shielded cable (This cable may be 

purchased at almost all professional sound and 

lighting stores). Your cables should be made with 

a male and female XLR connector on either end 

of the cable. Also remember that DMX cable must 

be daisy chained and cannot be split.

  Mini Dekker                                                      Set Up 

Figure 1

Содержание MINI DEKKER

Страница 1: ...rands and product names are trademarks or registered trademarks of their respective companies ADJ Products LLC and all affiliated companies hereby dis claim any and all liabilities for property equipment building and electrical damages injuries to any persons and direct or indirect economic loss associated with the use or reliance of any information contained within this document and or as a resul...

Страница 2: ...perfect operating condition Carefully check the ship ping carton for damage that may have occurred during shipping If the carton appears to be damaged carefully inspect your fixture for any damage and be sure all accessories necessary to operate the unit has arrived intact In the case damage has been found or parts are miss ing please contact our toll free customer support number for further instr...

Страница 3: ...n or water D The appliance does not appear to operate normally or exhibits a marked change in performance Power Supply The ADJ Mini Dekker contains a automatic voltage switch which will auto sense the voltage when it is plugged into the power source With this switch there is no need to worry about the cor rect power voltage this unit can be plugged in anywhere DMX 512 DMX is short for Digital Mult...

Страница 4: ... problems and interference It is always advisable to connect a DMX terminal Resistance 120 Ohm 1 4 W between PIN 2 DMX and PIN 3 DMX of the last fixture 1 2 3 1 2 3 DMX DMX COMMON DMX512 OUT 3 PIN XLR Figure 2 Figure 3 1 Ground 1 Ground XLR Male Socket XLR Pin Configuration 3 Hot 2 Cold 2 Cold 3 Hot XLR Female Socket Pin 3 Data True positive Pin 2 Data Compliment negative Pin 1 Ground Special Note...

Страница 5: ...l the patterns rotation and strobing A DMX controller allows you to create unique programs tailored to your individual needs 1 The Mini Dekker is a 9 DMX channel DMX fixture See page 10 for detailed description of the DMX values and traits 2 To control your fixture in DMX mode follow the set up procedures on pages 5 6 as well as the set up specifications that are included with your DMX controller ...

Страница 6: ...ment in which the fixture operates I e smoke fog residue dust dew In heavy club use we recommend cleaning on a monthly basis Periodic cleaning will en sure longevity and crisp output Mini Dekker Fuse Replacement Disconnect the unit from its power source Remove the power cord from the unit Once the cord has been removed you will find that the fuse holder is located inside the power socket Insert a ...

Страница 7: ...bsorb all expenses for warranty service and repair labor by reason of defects in material or workmanship The sole responsibility of ADJ Products LLC under this warranty shall be limited to the repair of the product or replacement thereof including parts at the sole discretion of ADJ Products LLC All products covered by this warranty were manufactured after August 15 2012 and bear indentifying mark...

Страница 8: ...design of this unit and this manual are subject to change without any prior written notice Auto Sensing Voltage This fixture contains a automatic voltage switch which will auto sense the voltage when it is plugged into the power source ADJ Products LLC www adj com Mini Dekker Instruction Manual Page 14 ADJ Products LLC 6122 S Eastern Ave Los Angeles CA 90040 USA Tel 323 582 2650 Fax 323 725 6100 W...

Отзывы: