  Mega Flat Tri Pak                                    Trouble Shooting

Listed below are a few common problems the user may encounter, 

with solutions.
Unit not responding to DMX:

1.  Check that the DMX cables are connected properly and are    

  wired correctly (pin 3 is “hot”; on some other DMX devices    

  pin 2 may be ‘hot’). Also, check that all cables are connected   

  to the right connectors; it does matter which way the inputs    

  and outputs are connected.
Unit does not respond to sound:

1.  Quiet or high pitched sounds will not activate the unit.

2.  Make sure that Sound Active mode is activated.

  Mega Flat Tri Pak                                                 Cleaning

Due to fog residue, smoke, and dust cleaning the internal and exter-

nal optical lenses must be carried out periodically to optimize light 

output.  

1.   Use normal glass cleaner and a soft cloth to wipe down the 

  outside casing.

2.   Clean the external optics with glass cleaner and a soft cloth 

  every 20 days.

3.  Always be sure to dry all parts completely before plugging 

  the unit back in.

Cleaning frequency depends on the environment in which the fixture 

operates (i.e. smoke, fog residue, dust, dew). 

Disconnect the unit from its power source. Remove the power cord 

from the unit. Once the cord has been removed, you will find that the 

fuse holder is located inside the power socket. Insert a flat-head screw 

driver into the power socket and gently pry out the fuse holder. Remove 

the bad fuse and replace with a new one. The fuse holder also has a 

holder for a spare fuse.

  Mega Flat Tri Pak                                  Fuse Replacement

ADJ Products, LLC  -  www.adj.com  - Mega Flat Tri Pak User Manual Page 17

ADJ Products, LLC  -  www.adj.com  - Mega Flat Tri Pak User Manual Page 18

With  this  feature  you  can  connect  the  fixtures  to  one  another 

using the IEC input and output sockets. The quantity that can be 

connected is 33 fixtures maximum. After 33 fixtures you will need 

to use a new power outlet. They must be the same fixtures. DO 

NOT mix fixtures.

  Mega Flat Tri Pak                        Power Cord Daisy Chain

  Channel   Value  

                Function

       

1                                                      RED

                       0 - 255                        0% - 100%           

       2                                                   GREEN

        

                                                                               

                 

                       0 - 255                        0% - 100%

       3                                                     BLUE

                       0 - 255                        0% - 100%

       4              0 - 255                   COLOR MACROS 

                                       

(See 1 Channel DMX mode for colors)

    

       5                                   STROBING/PROGRAM SPEED

                       0 - 15                          NOTHING

                     16 - 255           STROBING/SPEED CONTROL  

                                                         SLOW - FAST

       6                                                 PROGRAMS

                       0 - 127                               OFF

                   128 - 135                 COLOR DREAMING 1

                   136 - 143                 COLOR DREAMING 2

                   144 - 151                 COLOR DREAMING 3

                   152 - 159                 COLOR DREAMING 4

                   160 - 167                 COLOR DREAMING 5

                   168 - 175                 COLOR DREAMING 6

                   176 - 183                 COLOR DREAMING 7

                   184 - 191                 COLOR DREAMING 8

                   192 - 199                   COLOR CHANGE 1

                   200 - 207                   COLOR CHANGE 2

                   208 - 215                   COLOR CHANGE 3

                   216 - 223                   COLOR CHANGE 4

                   224 - 231                   COLOR CHANGE 5

                   232 - 239                   COLOR CHANGE 6

                   240 - 247               SOUND ACTIVE MODE 1

                   248 - 255               SOUND ACTIVE MODE 2

       7                                             MASTER DIMMER                                                     

                       0 - 255                          0% - 100%

Channels 1, 2, and 3 will not work, when Channel 4 is being used.

When using Channel 6 values 128-239, Channel 5 will control the speed of the programs. 

When using Channel 6 values 240-255, Channel 5 will control the sound sensitivity.

  Mega Flat Tri Pak     7 Channel - DMX Values & Functions

Содержание MEGA FLAT PAK

Страница 1: ...files during transport and dust free while storing The Mega TriPar Profile is a DMX intelligent high powered LED par fixture This fixture can be used in a stand alone mode or connected in a Master Sla...

Страница 2: ...nded by the manufacturer See page 18 for cleaning details Heat The appliance should be situated away from heat sources such as radiators heat registers stoves or other appliances inclu ding amplifiers...

Страница 3: ...aking your own ADJ Products LLC www adj com Mega Flat Tri Pak User Manual Page 5 Mega Flat Tri Pak Set Up ADJ Products LLC www adj com Mega Flat Tri Pak User Manual Page 6 Figure 1 cables Do not use t...

Страница 4: ...urrently dis played 2 The fixture will now change via sound 3 Press the SET UP button to adjust the sound sensitivity SJ X should be displayed Use the UP or DOWN buttons to adjust the sensitivity SJ 1...

Страница 5: ...s is the 3 Channel DMX Mode To run the 4 Channel Mode press the MODE button until Ch 04 is displayed This is the 4 Channel DMX Mode To run the 5 Channel Mode press the MODE button until Ch 05 is displ...

Страница 6: ...Please see pages 13 16 for DMX modes values and traits SOUND ACTIVE This button activates sound active mode SLAVE This designates the fixture as a slave fixture in a master slave configuration SET AD...

Страница 7: ...traits If the Red LED s glow you are in DMX Mode 1 1 DMX Channel If the Green LED s glow you are in DMX Mode 2 2 DMX Channels If the Blue LED s glow you are in DMX Mode 3 3 DMX Channels If the Red Gr...

Страница 8: ...ode for colors 2 0 255 DIMMER 0 100 Mega Flat Tri Pak 2 Channel DMX Values Functions Channels 1 2 and 3 will not work when Channel 5 is being used Channel Value Function 1 RED 0 255 0 100 2 GREEN 0 25...

Страница 9: ...Remove the bad fuse and replace with a new one The fuse holder also has a holder for a spare fuse Mega Flat Tri Pak Fuse Replacement ADJ Products LLC www adj com Mega Flat Tri Pak User Manual Page 17...

Страница 10: ...aged because not properly maintained as set forth in the instruction manual D This is not a service contract and this warranty does not include maintenance cleaning or periodic check up During the per...

Отзывы: