SAFETY PRECAUTIONS

•  Maximum ambient operating temperature is 113° F (45° C)!

•  DO NOT TOUCH the fixture housing during operation. Disconnect the power and allow approximately  15 

minutes for the fixture to cool down before servicing.

•  DO NOT shake the fixture, and avoid brute force when installing and/or operating the fixture.

•  DO NOT operate the fixture if the power cord has become frayed, crimped and/or damaged. If the  power 

cord is damaged, replace immediately with a new one of the same power rating.

•  DO NOT attempt to remove or break off the ground prong from the electrical cord. This prong is used to 

reduce the risk of electrical shock and fire in case of an internal short.

•  DO NOT attempt to operate this unit if it has been damaged in any way.

•  DO NOT spill water or other liquids into or on to your unit.

•  This unit is intended for indoor use only. Use of this product outdoors voids all warranties.

•  To reduce the risk of electrical shock or fire, do not expose this unit rain or moisture.

•  Disconnect from main power before making any type of connection.

•  DO NOT block any air ventilation slots. All fan and air inlets must remain clean and never blocked.  Allow 

approx. 6” (15cm) between fixture and other devices or a wall for proper cooling.

•  Always be sure to mount this unit in an area that will allow proper ventilation. Allow about 6” (15cm) 

between this device and a wall.

•  During the initial operation of this fixture, a light smoke or smell may emit from the interior of the  fixture. 

This is a normal process and is caused by excess paint in the interior of the casing burning  off from the 

heat. This will decrease gradually over time.

•  DO NOT remove the cover under for any reason. 

•  When installing fixture in a suspended enviroment, always use mounting hardware that is no less  than 

M10 x 25mm, and always install fixture with an appropriately rated safety cable.

•  Never plug this unit in to a dimmer pack.

•  During long periods of non-use, disconnect the unit’s main power.

•  Always mount this unit in safe and stable matter.

•  Power-supply cords should be routed so that they are not likely to be walked on or pinched by items 

placed upon or against them, paying particular attention to the point where they exit from the unit.

•  Cleaning - The fixture should be cleaned only as recommended by the manufacturer.

•  Heat - The appliance should be situated away from heat sources such as radiators, heat registers, stoves, 

or other appliances (including amplifiers) that produce heat.

•  The fixture should  be serviced by qualified service personnel when:

A. The power-supply cord or the plug have been damaged.

B. Objects have fallen onto, or liquid has been spilled into, the fixture.

C. The fixture has been exposed to rain or water.

D. The fixture does not appear to operate normally or exhibits a marked change in performance.

E. The fixture has fallen and/or has been subjected to extreme handling.

PROTECTION CLASS 1 - FIXTURE MUST BE PROPERLY GROUNDED.

THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT. DO NOT ATTEMPT 

ANY REPAIRS YOURSELF, AS DOING SO WILL VOID YOUR MANUFACTURER’S 

WARRANTY. DAMAGES RESULTING FROM MODIFICATIONS TO THIS FIXTURE 

AND/OR THE DISREGARD OF SAFETY INSTRUCTIONS AND GUIDELINES IN THIS 

MANUAL VOID THE MANUFACTURER’S WARRANTY AND ARE NOT SUBJECT TO 

ANY WARRANTY CLAIMS AND/OR REPAIRS.

NEVER LOOK DIRECTLY INTO THE LIGHT SOURCE!

RETINA INJURY RISK - MAY INDUCE BLINDNESS!

SENSITIVE PERSONS MAY SUFFER AN EPILEPTIC SHOCK!

Содержание FOCUS SPOT 6Z

Страница 1: ...User Manual FOCUS SPOT 6Z...

Страница 2: ...contained within this document and or as a result of the improper unsafe insufficient and negligent assembly installation rigging and opera tion of this product Europe Energy Saving Notice Energy Savi...

Страница 3: ...Safety Precautions 7 Installation 8 Maintenance Guidelines 12 Overview 13 DMX Set Up 14 DMX Addressing 16 DMX Traits 17 System Menu 24 Primary Secondary Set Up 28 Dimmer Modes 29 Gobo Replacement 30 G...

Страница 4: ...for private use Customer Support Contact ADJ Service for any product related service and support needs Also visit forums adj com with questions comments or suggestions Parts To purchase parts online...

Страница 5: ...arranty service and repair labor by reason of defects in material or workmanship The sole responsibility of ADJ Products LLC under this warranty shall be limited to the repair of the product or replac...

Страница 6: ...purchase All returned service items whether under warranty or not must be freight pre paid and accompanied by a return authorization R A number The R A number must be clearly writ ten on the outside o...

Страница 7: ...rease gradually over time DO NOT remove the cover under for any reason When installing fixture in a suspended enviroment always use mounting hardware that is no less than M10 x 25mm and always install...

Страница 8: ...perly certified to safely hold the combined weight of the fixture s clamps cables and accessories Maximum ambient operating temperature is 113 F 45 C Fixture s should be installed in areas outside wal...

Страница 9: ...iris shutters motors belts wiring discharge lamps and LEDs This issue is not specific only to ADJ lighting fixtures but rather it is a common issue with lighting fix tures from all manufacturers Alth...

Страница 10: ...of installation must be able to hold 10 times the weight of the unit and any attached accessories without any deformation The unit must be secured with a secondary safety attachment e g an appropriate...

Страница 11: ...re life The unit is fully operational in three different mounting positions hanging upside down from the ceil ing or trussing sideways on trussing or set on a flat level surface Be sure this fixture i...

Страница 12: ...electrical check by an approved electrical engineer every three months to make sure the circuit contacts are in good condition and prevent overheating B Be sure all screws and fasteners are securely...

Страница 13: ...Down Button 5 Enter Button 6 Right Button 7 Carry Handles 8 Mode Button 9 Up Button 10 Power Out 11 Power In 12 Fuse T5A 250V 13 Net In 14 Net Out 15 Safety Cable Attachment Point 16 5 pin DMX In 17...

Страница 14: ...of 1 the DMX controller knows to send DATA assigned to address 1 to that unit no matter where it is located in the DMX chain Data Cable DMX Cable Requirements For DMX Operation This unit can be contro...

Страница 15: ...ble terminator ADJ part number Z DMX T will reduce the risk of erratic behavior 5 Pin XLR DMX Connectors Some manufacturers use 5 pin DMX 512 data cables for DATA trans mission in place of 3 pin 5 pin...

Страница 16: ...ng all fixtures to the same DMX address will cause all fixtures to react in the same way In other words changing the settings of one channel will affect all the fixtures simultaneously If you set each...

Страница 17: ...127 Yellow 128 189 Clockwise fast to slow 190 193 No rotation 194 255 Counter clockwise slow to fast 4 6 6 Color Wheel 2 000 015 Open white 016 031 Orange Red 032 047 Yellow Green 048 063 Peacock Blue...

Страница 18: ...to fast 6 8 8 Gobo 1 Rotation 000 127 Indexing 128 189 Clockwise fast to slow 190 193 No rotation 194 255 Counter clockwise slow to fast 7 9 9 Gobo 2 Continuous Rotation 000 009 Open 010 019 Gobo 1 02...

Страница 19: ...ntensity 0 to 100 13 000 255 Dimmer Fine 0 to 100 11 13 14 Prism 1 000 031 Open 032 255 6 facet prism 12 14 15 Prism 1 Indexing and Rotation 000 127 Indexing 128 189 Clockwise fast to slow 190 193 No...

Страница 20: ...00 19 21 25 000 255 Frost Filter 2 0 to 100 22 26 Dim Modes 000 020 Standard 021 040 Stage 041 060 TV 061 080 Architectural 081 100 Theatre 101 120 Stage 2 Dimming Speed 121 0 1 s 122 0 2 s 123 0 3 s...

Страница 21: ...minimum 21 25 29 LED Refresh Rate 000 010 Default LED Refresh Rate 011 900 Hz 012 910 Hz 013 920 Hz 014 930 Hz 015 940 Hz 016 950 Hz 017 960 Hz 018 970 Hz 019 980 Hz 020 990 Hz 021 1000 Hz 022 1010 Hz...

Страница 22: ...44 1240 Hz 045 1250 Hz 046 1260 Hz 047 1270 Hz 048 1280 Hz 049 1290 Hz 050 1300 Hz 051 1310 Hz 052 1320 Hz 053 1330 Hz 054 1340 Hz 055 1350 Hz 056 1360 Hz 057 1370 Hz 058 1380 Hz 059 1390 Hz 060 1400...

Страница 23: ...nging 120 129 Enable blackout while gobo changing 130 139 Disable blackout while gobo changing Reset 140 149 Reset All 150 159 Reset Pan Tilt 160 169 Reset Color and Gobo 170 179 Reset Effects and Foc...

Страница 24: ...e ENTER button once more will confirm your setting You may exit the main menu at any time without making any adjustments by pressing the MENU button LCD CONTROL PANEL LOCKOUT When the Key Lock functio...

Страница 25: ...rt On Off P T Feedback On Off P T Speed Speed 1 Speed 2 Hibernation Off 01 99 min Default 15 min Fixture ID Service PIN Password 050 Universe 000 255 Unit IP Addr Mask Addr Protocol Set ArtNet sACN Ne...

Страница 26: ...Tilt Color Wheel 1 Color Wheel 2 Zoom Iris Frost1 Frost2 USB Port Power On Off Update Software Yes No Factory Restore Yes No Passcode 011 MANUAL CONTROL Pan 000 255 Pan Fine 000 255 Tilt 000 255 Tilt...

Страница 27: ...re run time Total LED Time LED On Time Lifetime LED run time non resettable LED On Resettable Time LED run time since last reset LED Hours Reset Passcode 050 Reset LED run time Fixture Temps LEDs Curr...

Страница 28: ...r is the input and the female XLR connector is the ouput The first unit in the chain primary will use the female XLR connector only The last unit in the chain will use the male XLR connector only 2 Pr...

Страница 29: ...ult 0 0 0 0 Stage 780 1100 1540 1660 TV 1180 1520 1860 1940 Architectural 1380 1730 2040 2120 Theatre 1580 1940 2230 2280 Stage 2 0 1100 0 1660 Rise Time Down Time Dimming Curve Ramp Effect 0 sec Fade...

Страница 30: ...screws that secure the cover to the head then remove the safety clip that attaches near the bottom of the head and remove the cover 2 Locate the gobo wheels and color wheels They are positioned near...

Страница 31: ...ur fingers and pull the gobo holder away from the gobo wheel right The gobo holder should come away easily DO NOT USE EXCESSIVE FORCE WHEN PERFORMING THIS STEP 4 Place the gobo holder with the black g...

Страница 32: ...cing you Rotate the geared portion of the gobo holder until the mark on the face of the geared portion is aligned with the clip of the gobo holder 8 Locate the large gear on the gobo wheel that meshes...

Страница 33: ...he black geared portion is aligned with the small circular magnet on the large gobo wheel gear 11 Re attached the safety clip from the cover to the attachment point at the base of the head Put the cov...

Страница 34: ...34 GOBOS...

Страница 35: ...35 COLOR WHEELS...

Страница 36: ...heck that all cables are con nected to the right connectors as connecting the inputs and outputs in the correct order is crucial for proper operation CLEANING Due to fog residue smoke and dust cleanin...

Страница 37: ...t any DMX connections from your device Insert the USB flash drive into the service port on your device 3 Use the display screen control panel to navigate to Personality Service USB Port Power See the...

Страница 38: ...38 DIMENSIONAL DRAWINGS Drawings may not be shown to scale...

Страница 39: ...or wash effect Frost 2 Light frost creates lightly blurred edges for GOBO and Prism FX Control 3 DMX Channel Modes 21 25 29 Channels Color LCD display with 6 button function menu Control Mode DMX512 o...

Страница 40: ......

Отзывы: