S A F E T Y  G U I D E L I N E S

To guarantee a smooth operation, it is important to follow all instructions and guidelines in this manual. 

ADJ Products, LLC is not responsible for injury and/or damages resulting from the misuse of this fixture 

due to the disregard of the information printed in this manual. Only qualified and/or certified personnel 

should perform installation of this fixture and only the original rigging parts included with this fixture 

should be used for installation. Any modifications to the fixture and/or the included mounting hardware 

will void the original manufactures warranty and increase the risk of damage and/or personal injury.

PROTECTION CLASS 1 - FIXTURE MUST BE PROPERLY GROUNDED

THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT. DO NOT ATTEMPT 

ANY REPAIRS YOURSELF; DOING SO WILL VOID YOUR MANUFACTURES WARRANTY. 

DAMAGES RESULTING FROM MODIFICATIONS TO THIS FIXTURE AND/OR THE 

DISREGARD OF SAFETY INSTRUCTIONS AND GUIDELINES IN THIS MANUAL VOID 

THE MANUFACTURES WARRANTY AND ARE NOT SUBJECT TO ANY WARRANTY 

CLAIMS AND/OR REPAIRS.

DO NOT PLUG FIXTURE INTO A DIMMER PACK!

NEVER OPEN THIS FIXTURE WHILE IN USE!

UNPLUG POWER BEFORE SERVICING FIXTURE!

NEVER TOUCH FIXTURE DURING OPERATION AS IT MAY BE HOT!

KEEP FLAMMABLE MATERIALS AWAY FROM FIXTURE!

ENSURE ALL CONNECTIONS AND END CAPS ARE PROPERLY SEALED WITH A 

DIELECTRIC GREASE (AVAILABLE AT MOST ELECTRICAL SUPPLIERS) TO PREVENT 

WATER CORROSION AND/OR ELECTRICAL SHORT CIRCUIT.

IF THE FIXTURE IS EXPOSED TO ENVIRONMENTAL TEMPERATURE CHANGES SUCH 

AS RELOCATION FROM AN OUTDOOR COLD TO AN INDOOR WARM ENVIRONMENT, 

DO NOT POWER THE FIXTURE ON IMMEDIATELY. INTERNAL CONDENSATION AS 

A RESULT OF ENVIRONMENTAL TEMPERATURE CHANGE CAN CAUSE INTERNAL 

FIXTURE DAMAGE. LEAVE THE FIXTURE POWERED OFF UNTIL IT HAS REACHED 

ROOM TEMPERATURE BEFORE POWERING ON.

NEVER LOOK DIRECTLY INTO THE LIGHT SOURCE! RETINA INJURY RISK - MAY 

INDUCE BLINDNESS! SENSITIVE PERSONS MAY SUFFER AN EPILEPTIC SHOCK!

THIS IS A RISK GROUP 3 (HIGH RISK) PRODUCT ACCORDING TO EN 62471 AND IEC/

TR 62778. THE LUMINAIRE SHOULD BE POSITIONED 63 METERS OR MORE FROM 

THE OUTPUT OF THE FIXTURE TO REDUCE OR ELIMINATE EXPOSURE.

6

Содержание Eliminator Lighting FROST FX BAR W

Страница 1: ...FROST FX BAR W User Instructions...

Страница 2: ...mation contained within this document and or as a result of the improper unsafe insufficient and negligent assembly installation rigging and operation of this product ADJ PRODUCTS LLC World Headquarte...

Страница 3: ...d Warranty USA Only 5 Safety Guidelines 6 Overview 8 Installation 9 DMX Set Up 12 DMX Addressing 14 System Menu 15 DMX Traits Channel Functions Values 16 Color Macro Chart 18 Dimmer Mode Chart 19 Powe...

Страница 4: ...t team for further instructions Please do not return this kit to your dealer without first contacting customer support at the number listed below Please do not discard the shipping carton in the trash...

Страница 5: ...ace defective parts at its expense with new or refurbished parts and will absorb all expenses for warrant service and repair labor by reason of defects in material or workmanship The sole responsibili...

Страница 6: ...MANUFACTURES WARRANTY AND ARE NOT SUBJECT TO ANY WARRANTY CLAIMS AND OR REPAIRS DO NOT PLUG FIXTURE INTO A DIMMER PACK NEVER OPEN THIS FIXTURE WHILE IN USE UNPLUG POWER BEFORE SERVICING FIXTURE NEVER...

Страница 7: ...tween fixture and other devices or a wall for proper cooling When installing fixture in a suspended environment always use mounting hardware that is no less than M10 x 25 mm and always attach an appro...

Страница 8: ...Display LED Locking Power Connector Input DOWN Button ESC Button Locking 3 Pin DMX Input Omega Bracket Mounting Hole Integrated Mounting Bracket and Safety Cable Attachment Point Locking Power Connec...

Страница 9: ...y surface a professional equipment installer MUST be consulted to determine if the metal truss structure or surface is properly certified to safely hold the combined weight of the fixture clamps cable...

Страница 10: ...ew and nut into the Omega brackets Insert the quick lock fasteners of the Omega brackets into the respective holes on the bottom of the Frost FX Bar W Tighten the quick lock fasteners fully clockwise...

Страница 11: ...safety inspection of all installation material and unit If you lack these qualifications do not attempt the installation yourself Installations should be checked by a skilled person once a year The Fr...

Страница 12: ...X address of 1 may be placed anywhere in a DMX line at the beginning at the end or anywhere in the middle When a fixture is assigned a DMX address of 1 the DMX controller knows to send DATA assigned t...

Страница 13: ...female XLR connector of the last unit in your daisy chain to terminate the line Using a cable terminator ADJ part number Z DMX T will decrease the possibilities of erratic behavior 5 Pin XLR DMX Conne...

Страница 14: ...xtures to react in the same way in other words changing the settings of one channel will affect all the fixtures simultaneously If you set each fixture to a different DMX address each unit will start...

Страница 15: ...Press UP to move up the next menu or to increase a selection value Down button press DOWN to move down to the next menu or to decrease a selection value ENTER button press ENTER to select menu or con...

Страница 16: ...255 0 100 55 55 55 55 Green Background Color 14 000 255 0 100 56 56 56 56 Blue Background Color 14 000 255 0 100 2 5 57 Background Color 1 14 COLOR TEMPERATURE LINEAR 2700 6000K 000 031 No Function 0...

Страница 17: ...0 104 Auto 6 105 119 Auto 7 120 134 Auto 8 135 149 Auto 9 150 164 Auto 10 165 179 Auto 11 180 194 Auto 12 195 209 Auto 13 210 224 Auto 14 225 239 Auto 15 240 255 Sound 2 10 10 13 62 65 000 255 White L...

Страница 18: ...147 164 212 R57 LAVENDER 96 103 88 2 163 R59 INDIGO 104 111 0 38 86 R361 HEMSLEY BLUE 112 119 0 142 208 R362 TIPTON BLUE 120 127 52 148 209 R64 LIGHT STEEL BLUE 128 135 1 134 201 R67 LIGHT SKY BLUE 13...

Страница 19: ...elay and Menu Display Time 121 0 1Sec 122 0 2Sec 123 0 3Sec 124 0 4Sec 125 0 5Sec 126 0 6Sec 127 0 7Sec 128 0 8Sec 129 0 9Sec 130 1 0Sec 131 1 5Sec 132 2 0Sec 133 3 0Sec 134 4 0Sec 135 5 0Sec 136 6 0S...

Страница 20: ...esidue smoke and dust cleaning the internal and external optical lenses must be carried out periodically to optimize light output 1 Use a damp microfiber cloth to wipe down the outside casing and to c...

Страница 21: ...ound mode Dimming 0 100 Angle 17 DMX Channel CH06 CH08 Ch14 CH14 CH56 CH60 CH66 CH69 Display 4 button LED display Connection 3 pin Data in out Power Connector in out Material Steel housing Dimensions...

Страница 22: ...DIMENSIONS 22...

Страница 23: ......

Отзывы: