ADI T-Max 3W G2 Скачать руководство пользователя страница 2

 

Applied Digital, Inc. 19315 Hwy 413   Branson West, MO 65737 

417-297-0361 F816-337-3398 web:www.appdig.com e-mail:[email protected] 

To cancel a session press the Start/Stop button on the T-Max® 3W G2 to pause the session. Then press and hold the Up button until the display 
shows a 0 or two dots if the clean room parameter is enabled. 

REMOTE SINGLE BED CONTROL (Master-Slave) 

Remote single bed control is the ability to control a T-Max® timer in the tanning room with a T-Max® 3W G2 at the front desk. Two T-Max® timers 
are required for remote single bed control: A T-Max® 3W G2 at the front desk (referred to as the Master) and a T-Max® timer in the tanning room 
(either a T-Max® 3W G2 or a T-Max® certified in bed timer. This timer is referred to as the salve). A Master T-Max® 3W G2 can only control one T-
Max® timer in the tanning room. 

WIRING 

Place one T-Max® 3W G2 in the tanning room and one at the desired remote location. Connect the 9V @ 300mA power supply to the “Pwr In” screw 
terminal on the back of each T-Max® 3W G2. Plug each power supply into a 120VAC outlet. Connect the T-Max® 3W G2 in the tanning room to the 
tanning bed as described. 

Run the provided modular cable from the tanning room to the remote T-Max® 3W G2. Connect the modular cable to one of the RJ-22 ports on each T-
Max® 3W G2. 

Note: If you are using the G2 wireless adapters, you do not need to run the modular cable. Connect the G2 access point to the T-Max® 3W G2 RJ-11 
connector shown in the diagram in this document and as described in the G2 Access Point documentation. 

CONFIGURATION 

Set the address on the T-Max® 3W G2 in the tanning room to “1”, and the address on the T-Max® 3W G2 at the front desk to “0” as described in the 
setting parameters section of this manual. When setting the address (parameter 1), make sure the period is not flashing. A flashing period means the 
address is over address 100. 

When setting the delay (parameter 3), set the delay on the Master T-Max® 3W G2 (the T-Max® 3W G2 at the front desk). 

SESSION CONTROL 

To start a session, press the Up or Down Button on the T-Max® 3W G2 at the front desk until the session time is displayed. Next press the Start/Stop 
button on the front desk T-Max® 3W G2 to start the session. 

If a delay other than 0 is set, the delay will count down. A period on the lower right corner of the display will flash rapidly. When the session starts, 
the period will flash at once per second rate. If there is no delay entered, the session will start immediately. 

To pause a session, press the Start/Stop button on the timer in the tanning room. The flashing period on the lower right corner of the display will stop 
flashing and stay illuminated. The session time will continue to count down and reflect the remaining session time. To restart the session, press the 
Start/Stop button on the timer in the tanning room. The period will continue flashing. 

To Cancel a session Press the Up and Down buttons on the T-Max® 3W G2 at the front desk at the same time. 

CLEAN ROOM 

Once the session time has elapsed, the display will show two solid periods only. This is an indication that the room needs to be cleaned. To clear the 
clean room indication, press and hold the Up button on the T-Max® 3W G2 in the tanning room until the two periods disappear and a “0” appears. To 
disable the clean room feature, set parameter 9 to a 0. 

CONNECTING THE EXTERNAL SPEAKER TO THE T-MAX® 3W G2 

An external speaker can be added to the T-Max® 3W G2 to provide a louder alarm. Simply connect the External Speaker to J6 on the back of the T-
Max® 3W G2. Set Parameter 20 to a 1 to enable the External Speaker as described in the setting parameters section. 

 
FIGURE - FRONT AND REAR VIEWS OF THE T-Max® 3W G2 

 

 

 

 

Front View of T-Max® 3W G2   

 

 

 

 

 

 

 

 

 

 

 

Rear View of T-Max® 3W G2 PCB 

 

(C) COPYRIGHT 1995-2011 By Applied Digital, Inc. 

T he information in this manual is believed to be correct. However, Applied Digital, Inc. assumes no responsibility for any errors herein. T his information is subject to 
change without notice, and should not be construed as a commitment by Applied Digital, Inc.  

WARRANT Y 

T his product is warranted against defective materials and workmanship for a period of two years from date of purchase. In the event the product fails to perform, it may be 
returned; Shipping Paid, to the factory to be serviced or replaced at the factory's discretion. Applied Digital, Inc. will pay to ship the repaired or replaced product by the 
shipping means of our choosing. Returns will not be accepted without a Return Authorization Number assigned by the factory. 

It is a Condition of Sale that the user of Applied Digital Inc.'s products assumes all risk and responsibility of use and indemnifies Applied Digital, Inc. against all damages. 
Applied Digital, Inc. is not liable for loss of profits, lost savings, special, incidental, consequential, indirect or other similar damages arising from breach of warranty, breach 
of contract, negligence, or other legal action even if Applied Digital, Inc. or its agent has been advised of the possibility of such damages, or for any claim brought against 
you by another party. T his warranty allocates risks of product failure between the purchaser and Applied Digital, Inc. Applied Digital, Inc.’s hardware pricing reflects this 
allocation of risk and the limitations of liability contained in this warranty. It is a violation of the stated warranty to cut or modify the provided modular cables supplied 
with the T -Max® Series T imers. Connecting the T -Max® Series to third party timers not approved by Applied Digital, Inc. also violates the stated warranty. Contact your 
dealer or Applied Digital, Inc. to determine if your third party timer is approved by Applied Digital, Inc. 

 

J4  -  PW R  IN  9-12V: 

Connect  9-12V  power  supply  to 

this terminal.

 

J3 - C ontact

: Connect the two wires from the tanning 

bed to these screw terminals. 

J6: 

Connector to connect external speaker for higher 

volume alarm. 

EXT Start –

 Connects to momentary external start 

button. 

TPI -

 Connects to front desk controller not made by 

Applied Digital, Inc. 

RJ-11 – Connects to the G2 Access point for 
wireless communications. 
RJ-22 – Connects to T-Max® cable for wired 

Relay 

Contact 

Pwr in 9-12V

 

Ext. Start

 

PIC Chip 

J6

 

T PI 

RJ-11 
 
 
RJ-22 