Keep the ash bed away from the primary air slots at the front of the fire. 

 

Notes:  

Only reload with wood when the previous load has been fully consumed, do not overload the combustion 

chamber. 

For well insulated houses or forced air ventilation in adjacent spaces, it is advisable to place a ventilation 

grid on an outside wall near the equipment of at least 100 cm2 and always be unobstructed. In this way, 

you supply the surrounding space with a good source of oxygen so that it does not run out, and the air 

masses move in the right direction. As for the air inlet grills, it must be taken into account that they must 

be positioned in such a way that their obstruction is not easy. In the case of simultaneous operation with 

other heating appliances, sufficient oxygen must be ensured. 

 

 

Warnings:  

 

This appliance was not designed to work with the door open.  Open the door for lighting and reloading 

only. Do not open the heater door suddenly or with the smoke control fully or partially closed, as the 

combustion chamber may overpressure, causing smoke or even flame out into the room.  

 

Excessive combustion does not necessarily translate into more heating power nor into an increase of 

efficiency. Furnacing may also cause irreparable damage to the appliance if carried out for long periods 

of time.

 

 

 

In the event of malfunction, immediately extinguish combustion by closing the fuel inlet control and the 

smoke control, causing the fire to extinguish by itself due to lack of oxygen. Expose the problem to our 

services and / or agents to be resolved

 

 

8-Cleaning and Maintenance 

 

To get the best out of your appliance, it should be regularly maintained, and the 

flue regularly swept. 

 

 

Cleaning and maintenance should always be carried out when the 

appliance is cold

 

 

 

 

Cleaning 

 

o

 

The glass should be kept reasonably clean by the airwash.   

In cases where a log has been left too close to or touching the glass, or green wood/kindling has 

been used then use a glass cleaner available from your retailer.   

Ensure the glass cleaner does not come into contact with the metal parts or the rope seal. 

o

 

When removing excess ash when/as required when fire is cool, place  ash  in a non-combustible 

container with a tightly fitting lid and move outdoors immediately to a location clear of combustible 

materials. 

 

 

Содержание ADH100DL

Страница 1: ...d by Castworks Pty Ltd 12 Fiveways Boulevard Keysborough VIC 3173 TESTED IN ACCORDANCE WITH AS NZS 4012 2014 AS NZS 4013 2014 Please read this manual thoroughly before installing and starting your fre...

Страница 2: ...cal Specifications 06 4 Installation Instructions 09 Flue Outlet 12 5 Fan 13 6 Installing the bricks and baffles 15 7 Instructions for use 16 8 Maintenance and cleaning 18 9 Troubleshooting 20 10 Warr...

Страница 3: ...om the sun and transform it into chemical energy The trapped energy e g in the form of wood pellets coal are called biomass fuels and can be converted into various forms electricity fuel or heat Bioma...

Страница 4: ...entilated Generally green wood should be left to season for two years Wood to Avoid Softwoods and low density wood This kind of firewood release a lot of heat but burn too quickly and projects embers...

Страница 5: ...e both the doors 5 Secondary convection outlet hot air distribution for ducting Inbuilt only 6 Smoke Outlet Flue collar 200mm 8 Crimped 7 Convection inlet Important o The compartment below the combust...

Страница 6: ...Factor g kg 1 1 Maximum firewood load kg 10 Minimum clearance distances from combustible materials mm See page 10 Flue Diameter mm 200 Recommended Fuel Burn only Harwood Moisture 20 Electrical Specifi...

Страница 7: ...air must be supplied to the room with the heater a minimum equivalent to half the cross sectional area of the flue ie 160cm2 free air o Follow the clearances to combustible materials as shown on page...

Страница 8: ...DO NOT USE FLAMMABLE LIQUIDS OR AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHEN IT IS OPERATING o WARNING DO NOT STORE FUEL WITHIN THE HEATER INSTALLATION CLEARANCES o WARNING WHEN OPERATING THIS APPL...

Страница 9: ...flue The active flue must be 8 for the entire length of the flue and always less than 45 degrees from the vertical The Flue terminal must meet the minimum height and external clearances for the flue...

Страница 10: ...r glass is 350mm The side clearance to the side of the heater is 150mm to combustibles ie island bench or log storage or similar The clearances to combustibles in front of either glass door is 1200mm...

Страница 11: ...d in the room is a solid 10 decorative flue shield The heater must have its own dedicated flue The active flue must be 8 for the entire length of the flue and always less than 45 degrees from the vert...

Страница 12: ...so be as high as any nearby structure within a 6m Radius AS 2918 2018 External Requirements Refer to AS NZS 2918 2018 Note All external air vents ceiling penetrations must be bird rodent proofed with...

Страница 13: ...the base will need a custom designed fan cut out in the bench with air supply to each fan below the heater base A cable will need to run from the heater to a wall mount controller the 240V power supp...

Страница 14: ...ystem is well dimensioned ensuring proper drainage and that it complies with the Australian standards in force so that there is no undue smoke escape into the surrounding space Keep combustible and fl...

Страница 15: ...he central one across the middle on the side bricks and the outer C channel support bars 6 front and back Begin with the side baffle bricks resting on the side bricks then insert the middle brick and...

Страница 16: ...resting against each other to allow maximum air flow around the wood and so the kindling doesn t collapse Use about 1kg of split small logs of dry wood 5 Keep the door slightly open allowing the amoun...

Страница 17: ...ng smoke or even flame out into the room Excessive combustion does not necessarily translate into more heating power nor into an increase of efficiency Furnacing may also cause irreparable damage to t...

Страница 18: ...a small fire initially and keep windows open for ventilation o Clean the chimney and the flame baffle at least once a year using a qualified technician if necessary o Periodically check and replace th...

Страница 19: ...burn Wet or green firewood Dirty or clogged chimney Insufficient firewood Use dry wood Clean the chimney Very fast burning Low density firewood Poorly adjusted door Filling cord consumed Load the sto...

Страница 20: ...od 2 The complaint must be presented and validated by one of our agents and endorsed by ADF 3 The installation use and maintenance conditions described in this manual have been strictly respected and...

Страница 21: ..._____________________________ Client Signature Note The Warranty is limited to the replacement repair by ADF or its agent of the components known to be defective and excludes any other type of coverag...

Страница 22: ...2014 AS NZS 4013 2014 Burning Hardwood Maximum Avearge Heat Output kW 18 9 Overall Average Efficiency 60 Particulate Emission Factor g kg 1 1 Maximum firewood load kg 12 Minimum clearance distances f...

Отзывы: