4-Installation
All local regulations, including those that reference to national or
European standards must be adhered to when installing the
apparatus.
The Chimney
You will only get the maximum efficiency from your appliance if the chimney is also efficient.
Before installing your ADF appliance check that the chimney is clean and unobstructed. If you
have any difficulties ask a professional to examine the chimney.
Both the height of the chimney, as well as breaks in
pressure in the chimneys are directly related to your
drawing, so the line must have the most straight as
possible, or failing which trajectory never suffer higher
angular deviation at 45 º to the vertical.
It is also ideal that
the construction of the conduct of the flue passes through
the interior of the building thus ensuring better insulation,
and so avoid unwanted condensation originated by
temperature differentials, which sooner or later may
damage the system. (Not suitable are the flue ducts from
the outside and without insulation).
The chimneys must have individual outputs flues, and is
totally inadvisable grouping several chimneys in collective
behaviors. The outlet smoke pipes must have constant
section from the output of the stove to exhaust venting to
the atmosphere. Recommended for the exits for fumes of
fireplaces dimensions are defined in the Technical data
table.
The hat of the chimney must not possess an obstructive
manner towards the currents of outer air, ie it must allow air
to enter through the side exit can access the opposite side
causing no air currents descendants.