background image

 

 

 
 

 

 
 

 

 
 

 

 

Installation and User’s Manual 

 

 

NV Series 

 

 

 

 

  

 

 

 
 
 

 
 
 

 
 
 

 

 It is important to read this manual carefully before 

installing and using your appliance.

 

                     V1_05_06_2014

 

Содержание 1000 NMV DF

Страница 1: ...Installation and User s Manual NV Series It is important to read this manual carefully before installing and using your appliance V1_05_06_2014...

Страница 2: ...ion 3 2 Diagram of equipment 6 3 Technical Features 7 4 Installation 10 5 Fan kit Diagram 17 6 Using the equiment 18 7 Maintenance and Cleaning 19 8 Troubleshooting 22 9 Warranty Conditions 23 10 Warr...

Страница 3: ...d for its correct installation and use Wood An ecological form of energy As a totally renewable resource wood is the most ecological and economical way of producing heat in your home The quantity of C...

Страница 4: ...t of smoke and a poor flame which creates soot inside the stove on the glass and in the chimney Wood should be covered or sheltered from the rain but well ventilated Generally the wood should have a d...

Страница 5: ...eleased through the upper part of the stove This phenomena is called natural convection You may also choose to install a fan in the base of the stove in order to obtain forced convection so as to incr...

Страница 6: ...ection 2 Air combustion control 9 Admission convection 3 Refractory firebox panel 10 Screw lock s the convection distribution see pg 10 4 Convection primary control 11 Fan controller Ventilator 5 Flue...

Страница 7: ...n products C 401 410 431 Chimney draft at nominal heat output Pa 12 12 12 Flue outlet mm mm 180 200 200 Width carter front mm 685 720 829 862 1007 1040 Height carter front mm 565 580 565 580 565 580 D...

Страница 8: ...tions must be complied with The appliance must be installed in such a way as to make maintenance easy The incorrect installation of the appliance could cause serious damage to the appliance and put pe...

Страница 9: ...s of your appliance and the loss of guarantee The appliance is not a toy Keep children away from it Check that the flue system is properly sized ensuring a good run and that meets European standards s...

Страница 10: ...so ideal that the construction of the conduct of the flue passes through the interior of the building thus ensuring better insulation and so avoid unwanted condensation originated by temperature diffe...

Страница 11: ...ately 5 mm to each side of the fireplace Should never obstruct the vents It is also desirable that in homes with good insulation and or possessing contiguous spaces with exhaustion is placed a grill v...

Страница 12: ...preferably in stainless steel and thermally insulated along its whole length in order to avoid condensation specially in cold climates Chimneys should have a single flue and the grouping of several c...

Страница 13: ...account therefore the fixing of the tubing should not be permanent The chimney must be at least 0 6m from the highest part of the roof In any other area which is not the highest point it should be at...

Страница 14: ...t of air from the appliance 3 Entrance of air into the appliance chamber 4 Exit of air from the appliance chamber 1 Entrance of air into the appliance 2 Exit of air from the appliance to other rooms 3...

Страница 15: ...stances should the appliance be cemented into its surroundings Sufficient space should be left for it to expand and contract freely typically 5mm around its whole perimeter It is recommended that at l...

Страница 16: ...imneys Requirements and test methods EN13069 2005 Chimneys clay ceramic outer walls for system chimneys Requirements and test methods EN 13063 2006 system chimneys with clay ceramic flue liners Parte...

Страница 17: ...rd has special technical features Electric Scheme Operation of the Fan I Thermostat Low Speed 0 off II Manual High Speed ATTENTION Remove side covers With fans slap frame is necessary to leave open lo...

Страница 18: ...ntrol completely open 6 After 5 to 10 minutes close the door reduce the amount of air coming in through the air combustion control 7 Let the fire burn until it creates the first embers Note Thin and d...

Страница 19: ...ey The area of the fresh air grill should be at least 100 cm2 and should always be kept unblocked 7 Maintenance and Cleaning Your appliance can function for various years without any major maintenance...

Страница 20: ...e chimney and the neck of the chimney remove flame deflector at least once a year If necessary ask a qualified professional to do the job Periodically check and replace where necessary the sealing cor...

Страница 21: ...made to the product without due written authorization from the Manufacturer Manufacturer Antonino Dias Fernandes Lda Adress Zona Industrial da Relvinha Sarzedo Apartado 55 3304 909 Arganil Classificat...

Страница 22: ...drier wood Clean chimney Burning poorly and inefficiently Damp or green wood Dirty or blocked chimney Not enough wood Use drier wood Clean chimney Burning too fast Wood is too light Door not properly...

Страница 23: ...of firewood and operating systems Conditions of Guarantee I The appliance is within the time limits described above the beginning of this period of guarantee having begun on the date the appliance was...

Страница 24: ..._ _____________________________ Client Signature Note The guarantee covers the exchange and or restoration by ADF or its agent of the components that are acknowledged as damaged and excludes any other...

Страница 25: ...25...

Страница 26: ...26...

Страница 27: ...27...

Страница 28: ...28 Www adf pt adf adf pt...

Отзывы: