background image

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com S.r.l. 

 

User Manual   

EtherCAT Slave / SNMP Manager

 

 

Document code: MN67E24_ENG     Revision 1.000   Page 16 of 26

 

 

 

SET COMMUNICATION:

 

 

 

This  section  define  the  fundamental  communication  parameters  of  two  buses, 
EtherCAT and SNMP. 
 
By  Pressing  the  “

Set  Communication

”  button  from  the  main  window  for  SW67E24 

(Fig. 2) the window “Set Communication” appears (Fig. 3). 
 
The means of the fields for “EtherCAT Slave” are: 

 

In  the  field  “

Revision  Number

”  the  revision  number  of  the  converter  is 

defined; 

 

In the field “

Slave Name

” the name of the converter is defined; 

 

In the field 

“Node Address

” the ID of the converter is defined. 

 

The means of the fields for “SNMP Manager” are: 

 

In the field “

IP ADDRESS

” the IP address that you want to give to the SNMP 

side is defined; 

 

In the field “

SUBNET

 

Mask

” the SubNet Mask of the SNMP side is defined; 

 

In the field “

GATEWAY

” the default gateway that you want to use is defined. 

This  feature  can  be  enabled  or  disabled  pressing  the  Check  Box  field.  This 
feature is used for going out of the net; 

 

In  the  field  "

Name  of  Station

"  it  is  possible  to  assign  a  name  to  the  SNMP 

node. 

 
 
 
 
 
 
 
 
 
 
 

Figure 3: “Set Communication” window

 

Содержание HD67E24-A1

Страница 1: ...Product HD67E05 BACnet Master www adfweb com Product HD67E06 BACnet Slave www adfweb com Product HD67E07 CAN www adfweb com Product HD67E08 CANopen www adfweb com Product HD67E09 DeviceNet Master www...

Страница 2: ...ES AND TECHNICAL SUPPORT 26 RETURN POLICY 26 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related...

Страница 3: ...device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operati...

Страница 4: ...Industrial Electronic Devices ADFweb com S r l User Manual EtherCAT Slave SNMP Manager Document code MN67E24_ENG Revision 1 000 Page 4 of 26 EXAMPLE OF CONNECTION...

Страница 5: ...Industrial Electronic Devices ADFweb com S r l User Manual EtherCAT Slave SNMP Manager Document code MN67E24_ENG Revision 1 000 Page 5 of 26 CONNECTION SCHEME Figure 1 Connection scheme for HD67E24 A1...

Страница 6: ...formation between EtherCAT bus and SNMP bus Mountable on 35mm Rail DIN Wide power supply input range 8 24V AC or 12 35V DC Wide temperature range 40 C 85 C 40 F 185 F CONFIGURATION You need Compositor...

Страница 7: ...67E24_ENG Revision 1 000 Page 7 of 26 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 24V 12V 35V Consumption...

Страница 8: ...on the position of the Dip1 of Dip Switch A The first with Dip1 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip1 of Dip Switch A at ON position is used...

Страница 9: ...3 SNMP comm green It blinks when SNMP communication is running Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 4 Error state green ON An error in the communication busses occurs...

Страница 10: ...standard Ethernet packet or frame according to IEEE 802 3 is no longer received interpreted and copied as process data at every node The EtherCAT slave devices read the data addressed to them while th...

Страница 11: ...ion and the updating of the converter must be made using Connector9 and or Connector10 of the HD67E24 A1 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The ca...

Страница 12: ...at runs with Windows called SW67E24 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last version of the software present...

Страница 13: ...s configuration A device s configuration can also be imported or exported To clone the configurations of a programmable EtherCAT SNMP Converter in order to configure another device in the same manner...

Страница 14: ...e the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possible...

Страница 15: ...CAT Slave SNMP Manager Document code MN67E24_ENG Revision 1 000 Page 15 of 26 In the section Software Settings it is possible to enable disable some keyboard s commands for an easier navigation inside...

Страница 16: ...n number of the converter is defined In the field Slave Name the name of the converter is defined In the field Node Address the ID of the converter is defined The means of the fields for SNMP Manager...

Страница 17: ...he EtherCAT Master Master To Slave SLAVE TO MASTER The means of the fields are If the field Enable is checked the EtherCAT variable is enabled In the field Type the data format of the EtherCAT variabl...

Страница 18: ...iable is enabled In the field Type the data format of the EtherCAT variable is defined In the field Lenght the dimension of the EtherCAT variable is defined In the field Name the name of the EtherCAT...

Страница 19: ...n the field OID the OID to read write from to the SNMP Agent device is defined In the field Type the type of data to read write String or Int is defined In the field Mode the type of SNMP request used...

Страница 20: ...eld Priv Pass the password for Privacy authentication is defined o In the field Security Level the type of security used is defined o In the field Auth Mode the mode used for the authentication is def...

Страница 21: ...hernet cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF the Device Put Dip1...

Страница 22: ...e program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure that you have the administrator privileges In case you have to program...

Страница 23: ...al Electronic Devices ADFweb com S r l User Manual EtherCAT Slave SNMP Manager Document code MN67E24_ENG Revision 1 000 Page 23 of 26 MECHANICAL DIMENSIONS Figure 8 Mechanical dimensions scheme for HD...

Страница 24: ...combination of the following HD67E24 xx Connectors Type 1 Removable 5mm Screw Terminal Enclosure Type A 1M 35mm DIN Rail mounting Device Family HD67E24 EtherCAT Slave SNMP Manager Converter Order Code...

Страница 25: ...ction systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the re...

Страница 26: ...e do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product...

Отзывы: